A fiberoptic sensor for tissue carbon dioxide monitoring

被引:0
|
作者
Davenport, John J. [1 ]
Hickey, Michelle [1 ]
Phillips, Justin P. [1 ]
Kyriacou, Panicos A. [1 ]
机构
[1] City Univ London, Sch Comp Sci Math & Engn, London EC1V 0HB, England
基金
美国国家卫生研究院;
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We present a new fiberoptic carbon dioxide sensor for transcutaneous and mucosa (indwelling) blood gas monitoring. The sensor is based on optical fluorescence of molecules sensitive to pH changes associated with dissolved CO2. A three layer chemical coating was dip-coated onto the distal tip of an optical fiber (600 mu m core radius). It contained the 50mg/ml 'polym H7', a coating polymer bonded to a fluorescence indicator dye, along with 125mg/ml of the transfer agent tetraoctylammonium hydroxide (TONOH). Light from a blue (460 nm) LED was launched into the fiber to excite the sensing film. The sensing film fluoresced green (530 nm), the intensity of which decreased in the presence of CO2. The sensor was tested in vitro, finding a correlation between change in fluorescence (in AU) and aqueous CO2 concentration with a minimum detection threshold of 40%. The sensor is being developed for medical applications where its small size and ability to continuously monitor the partial pressure of CO2 (PCO2) will make it an extremely useful diagnostic tool.
引用
收藏
页码:7942 / 7945
页数:4
相关论文
共 50 条
  • [41] FLEXIBLE NONTOXIC FIBEROPTIC DELIVERY SYSTEM FOR THE CARBON-DIOXIDE LASER
    RONTAL, M
    RONTAL, E
    FULLER, T
    JACOB, HJ
    [J]. ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1985, 94 (04): : 357 - 360
  • [42] THE USE OF CARBON-DIOXIDE FIBEROPTIC LASER CATHETER FOR ATRIAL SEPTOSTOMY
    ZEEVI, B
    GAL, D
    WOLF, N
    BERANT, M
    ABRAMOVICI, A
    BLIEDEN, LC
    KATZIR, A
    [J]. AMERICAN HEART JOURNAL, 1988, 116 (01) : 117 - 122
  • [43] Sensor array for wireless remote monitoring of carbon dioxide and methane near carbon sequestration and oil recovery sites
    Honeycutt, Wesley T.
    Kim, Taehwan
    Ley, M. Tyler
    Materer, Nicholas F.
    [J]. RSC ADVANCES, 2021, 11 (12) : 6972 - 6984
  • [44] Field demonstration of a 1 x 4 fiber sensor array for subsurface carbon dioxide monitoring for carbon sequestration
    Soukup, Benjamin
    Repasky, Kevin S.
    Carlsten, John L.
    Wicks, Geoff
    [J]. JOURNAL OF APPLIED REMOTE SENSING, 2014, 8
  • [45] A miniature chemiresistor sensor for carbon dioxide
    Srinives, Sira
    Sarkar, Tapan
    Hernandez, Raul
    Mulchandani, Ashok
    [J]. ANALYTICA CHIMICA ACTA, 2015, 874 : 54 - 58
  • [46] GaN Based Carbon Dioxide Sensor
    Jung, Sunwoo
    Baik, Kwang Hyeon
    Jang, Soohwan
    [J]. WIDE BANDGAP SEMICONDUCTOR MATERIALS AND DEVICES 18, 2017, 77 (06): : 121 - 125
  • [47] MONITORING THE COMPOSITE CURING PROCESS WITH A FLUORESCENCE-BASED FIBEROPTIC SENSOR
    LEVY, RL
    SCHWAB, SD
    [J]. POLYMER COMPOSITES, 1991, 12 (02) : 96 - 101
  • [48] Phase fluorometric optical carbon dioxide gas sensor for fermentation off-gas monitoring
    Sipior, J
    RandersEichhorn, L
    Lakowicz, JR
    Carter, GM
    Rao, G
    [J]. BIOTECHNOLOGY PROGRESS, 1996, 12 (02) : 266 - 271
  • [49] Ratiometric fluorescence-based dissolved carbon dioxide sensor for use in environmental monitoring applications
    Dorota Wencel
    John P. Moore
    Niall Stevenson
    Colette McDonagh
    [J]. Analytical and Bioanalytical Chemistry, 2010, 398 : 1899 - 1907
  • [50] Erratum to: A novel planar optical sensor for simultaneous monitoring of oxygen, carbon dioxide, pH and temperature
    Sergey M. Borisov
    Roman Seifner
    Ingo Klimant