Design of a Triple-Axis MEMS-Based Fluidic Gyroscope

被引:0
|
作者
Thien Xuan Dinh [1 ]
Ogami, Yoshifumi [1 ]
机构
[1] Ritsumeikan Univ, Dept Mech Engn, Kusatsu, Shiga 5258577, Japan
关键词
FLOW;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, we present a realizable structure and simulation of a triple-axis microelectromechanical system (MEMS)-based fluidic gyroscope sensor. The computational fluid dynamics FLUENT package is employed to obtain a fully transient flow solution that includes the effect of angular rate. In the sensor, four axisymmetric jets comprising two perpendicular pairs of flows are generated in a fluidic network by a piezoelectric actuator, without requiring any check valve. The angular rate is measured using the deflection of the jets under apparent Coriolis acceleration by an in-plane hot wire system. The heat transfer between the hotwire and the ambient gas is calibrated for a low velocity of the gas flow. The structure of the sensor is considered to diminish the cross-sensitivity between the horizontal and vertical components of angular rate. The hot wires can be fabricated by a mass standard MEMS process with only one mask, and the fluidic network can be fabricated by a hot embossing technique.
引用
收藏
页码:1112 / 1115
页数:4
相关论文
共 50 条
  • [31] Commissioning of neutron triple-axis spectrometers at HANARO
    Hiraka, Haruhiro
    Lee, Jisung
    Jeon, Byoungil
    Seong, Baek-Seok
    Cho, Sangjin
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2020, 52 (09) : 2138 - 2150
  • [32] RESOLUTION FUNCTION OF A TRIPLE-AXIS NEUTRON SPECTROMETER
    GRABCEV, B
    NUCLEAR INSTRUMENTS & METHODS, 1973, 106 (02): : 349 - 355
  • [33] Design of the cold neutron triple-axis spectrometer at the China Advanced Research Reactor
    Cheng, P.
    Zhang, Hongxia
    Bao, W.
    Schneidewind, A.
    Link, P.
    Gruenwald, A. T. D.
    Georgii, R.
    Hao, L. J.
    Liu, Y. T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 821 : 17 - 22
  • [34] RESOLUTION CONSIDERATIONS FOR POLARIZED TRIPLE-AXIS SPECTROMETRY
    ROSOV, N
    LYNN, JW
    ERWIN, RW
    PHYSICA B, 1992, 180 : 1003 - 1004
  • [35] FOCUSING EFFECTS IN TRIPLE-AXIS NEUTRON SPECTROMETERS
    COLLINS, MF
    BRITISH JOURNAL OF APPLIED PHYSICS, 1963, 14 (11): : 805 - &
  • [36] MEMS-Based Nanomechanics: Influence of MEMS Design on Test Temperature
    Pant, B.
    Choi, S.
    Baumert, E. K.
    Allen, B. L.
    Graham, S.
    Gall, K.
    Pierron, O. N.
    EXPERIMENTAL MECHANICS, 2012, 52 (06) : 607 - 617
  • [37] MEMS-based nanomechanics: Influence of MEMS design on test temperature
    Pant, B.
    Choi, S.
    Baumert, E.K.
    Allen, B.L.
    Graham, S.
    Gall, K.
    Pierron, O.N.
    Proceedings of the Society for Experimental Mechanics, Inc., 2012, 52 (01): : 607 - 617
  • [38] MEMS-Based Nanomechanics: Influence of MEMS Design on Test Temperature
    B. Pant
    S. Choi
    E. K. Baumert
    B. L. Allen
    S. Graham
    K. Gall
    O. N. Pierron
    Experimental Mechanics, 2012, 52 : 607 - 617
  • [39] RESOLUTION FUNCTION OF A TRIPLE-AXIS NEUTRON SPECTROMETER
    BOBROVSKII, VI
    GOSHCHITSKII, BN
    MIRMELSHTEIN, AV
    MIKHAILOV, YN
    KRISTALLOGRAFIYA, 1975, 20 (03): : 504 - 510
  • [40] FOCUSING CONDITIONS FOR A TRIPLE-AXIS NEUTRON SPECTROMETER
    PECKHAM, GE
    SAUNDERSON, DH
    SHARP, RI
    BRITISH JOURNAL OF APPLIED PHYSICS, 1967, 18 (04): : 473 - +