Design of a Triple-Axis MEMS-Based Fluidic Gyroscope

被引:0
|
作者
Thien Xuan Dinh [1 ]
Ogami, Yoshifumi [1 ]
机构
[1] Ritsumeikan Univ, Dept Mech Engn, Kusatsu, Shiga 5258577, Japan
关键词
FLOW;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, we present a realizable structure and simulation of a triple-axis microelectromechanical system (MEMS)-based fluidic gyroscope sensor. The computational fluid dynamics FLUENT package is employed to obtain a fully transient flow solution that includes the effect of angular rate. In the sensor, four axisymmetric jets comprising two perpendicular pairs of flows are generated in a fluidic network by a piezoelectric actuator, without requiring any check valve. The angular rate is measured using the deflection of the jets under apparent Coriolis acceleration by an in-plane hot wire system. The heat transfer between the hotwire and the ambient gas is calibrated for a low velocity of the gas flow. The structure of the sensor is considered to diminish the cross-sensitivity between the horizontal and vertical components of angular rate. The hot wires can be fabricated by a mass standard MEMS process with only one mask, and the fluidic network can be fabricated by a hot embossing technique.
引用
收藏
页码:1112 / 1115
页数:4
相关论文
共 50 条
  • [21] FOCUSING CONDITIONS FOR A TRIPLE-AXIS SPECTROMETER
    MARX, D
    ZEITSCHRIFT FUR ANGEWANDTE PHYSIK, 1971, 32 (04): : 296 - &
  • [22] The Triple-Axis Pact and American Reactions
    Smith, Robert Aura
    ANNALS OF THE AMERICAN ACADEMY OF POLITICAL AND SOCIAL SCIENCE, 1941, 215 : 127 - 132
  • [23] Motion planning for triple-axis spectrometers
    Weber, Tobias
    SOFTWAREX, 2023, 23
  • [24] LORENTZ FACTOR FOR TRIPLE-AXIS SPECTROMETERS
    PYNN, R
    ACTA CRYSTALLOGRAPHICA SECTION B-STRUCTURAL SCIENCE, 1975, 31 (OCT15): : 2555 - 2556
  • [25] A MEMS-based opto-acoustic-fluidic system for cell imaging
    Wang, Min
    Jin, Tian
    Liu, Fei
    Chen, Xingxing
    Xi, Lei
    ELEVENTH INTERNATIONAL CONFERENCE ON INFORMATION OPTICS AND PHOTONICS (CIOP 2019), 2019, 11209
  • [26] Design and Analysis of MEMS-based Actuator
    Liu, Shuangjie
    Hao, Yongping
    MANUFACTURING SCIENCE AND ENGINEERING, PTS 1-5, 2010, 97-101 : 3471 - +
  • [27] A fully integrated MEMS-based convective 3-DOF gyroscope
    Dao, Dzung Viet
    Dan, Van Thanh
    Dinh, Thien Xuan
    Sugiyama, Susumu
    TRANSDUCERS '07 & EUROSENSORS XXI, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2007,
  • [28] Fluidic mechanism for dual-axis gyroscope
    Van Thanh Dau
    Thien Xuan Dinh
    Canh Dung Tran
    Phong Nhu Bui
    Du Dinh Vien
    Hoa Thanh Phan
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2018, 108 : 73 - 87
  • [29] Instrumental origin effects in triple-axis diffraction
    Gartstein, E
    Mandelbrot, M
    Mogilyanski, D
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2001, 34 (10A) : A57 - A63
  • [30] A TRIPLE-AXIS SPECTROMETER FOR NEUTRON INELASTIC SCATTERING
    CHUMBLEY, L
    DYER, RF
    WALLIS, DE
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1968, 1 (05): : 528 - &