Sample temperature effect on laser ablation and analytical capabilities of laser induced breakdown spectroscopy

被引:36
|
作者
Lednev, V. N. [1 ,2 ]
Grishin, M. Ya. [1 ,3 ]
Sdvizhenskii, P. A. [1 ,2 ]
Asyutin, R. D. [4 ]
Tretyakov, R. S. [4 ]
Stavertiy, A. Ya. [4 ]
Pershin, S. M. [1 ]
机构
[1] Russian Acad Sci, Prokhorov Gen Phys Inst, Moscow, Russia
[2] Natl Univ Sci & Technol MISiS, Moscow, Russia
[3] State Univ, Moscow Inst Phys & Technol, Dolgoprudnyi, Moscow Region, Russia
[4] Bauman Moscow State Tech Univ, Moscow, Russia
基金
俄罗斯科学基金会;
关键词
QUANTITATIVE-ANALYSIS; OPTICAL-EMISSION; LIQUID STEEL; ALLOY-STEEL; MOLTEN; METAL; LIBS; SPECTROMETRY; PLASMAS;
D O I
10.1039/c8ja00348c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The influence of sample temperature on the laser ablation process and analytical capabilities of laser induced breakdown spectroscopy (LIBS) was studied systematically. We were interested in estimating the analytical capabilities of a LIBS probe which was developed for in situ elemental analysis of molten metals during the production of metal parts by additive manufacturing. The sample surface was heated locally (4 mm diameter spot) in an argon atmosphere using a powerful continuous wave fiber laser while a nanosecond laser ablated only a small spot (0.3 mm diameter) in the high temperature area. This procedure can be utilized for high temperature LIBS studies of any samples including materials with high melting temperatures (tungsten, aluminum oxide etc.). Low alloy steel samples were heated up to their melting points and LIBS experiments were carried out in a wide temperature range (25-1600 degrees C). LIBS plasma imaging revealed that the size and brightness of the expanding plume did not depend on solid sample temperature but these parameters increased manifold for molten steel ablation. Comparison of plasma emissivity, temperature and electron density did not reveal any meaningful differences in the case of LIBS measurements for room temperature (25 degrees C), hot solid (1050 degrees C) and molten (1550 degrees C) targets, and thus enhanced plasma emissivity was attributed to greater ablation rate. The surface temperature impact on LIBS analytical capabilities was studied by comparing calibration curve linearity, limits of detection and the root mean square error of cross-validation for chromium, silicon and manganese. High temperature of the sample surface favored greater atomic/ionic line emission but molten sample LIBS analysis revealed poor limits of detection for all elements, which was explained by strong fluctuations of the laser ablation process at the liquid metal surface.
引用
收藏
页码:607 / 615
页数:9
相关论文
共 50 条
  • [41] Laser ablation assisted spark induced breakdown spectroscopy and its application
    Zhou, Wei-Dong
    Guo, Yu-Hui
    Zhang, Ran-Ran
    FRONTIERS OF PHYSICS, 2020, 15 (05)
  • [42] Laser ablation of copper based alloys by single and double pulse laser induced breakdown spectroscopy
    L. Caneve
    F. Colao
    R. Fantoni
    V. Spizzichino
    Applied Physics A, 2006, 85 : 151 - 157
  • [43] Simulation of multi-pulse laser ablation for laser-induced breakdown spectroscopy applications
    Mikhail E. Povarnitsyn
    Pavel R. Levashov
    Applied Physics A, 2019, 125
  • [44] Characterization of laser ablation of copper in the irradiance regime of laser-induced breakdown spectroscopy analysis
    Picard, J.
    Sirven, J. -B.
    Lacour, J. -L.
    Musset, O.
    Cardona, D.
    Hubinois, J-C.
    Mauchien, P.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2014, 101 : 164 - 170
  • [45] Elemental fractionation in aerosol laser-induced breakdown spectroscopy with nanosecond and femtosecond laser ablation
    Latty, Kyle S.
    Hartig, Kyle C.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2023, 202
  • [46] Laser ablation of copper based alloys by single and double pulse laser induced breakdown spectroscopy
    Caneve, L.
    Colao, F.
    Fantoni, R.
    Spizzichino, V.
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2006, 85 (02): : 151 - 157
  • [47] The effect of sample temperature on the emission line intensification mechanisms in orthogonal double-pulse Laser Induced Breakdown Spectroscopy
    Sangines, R.
    Sobral, H.
    Alvarez-Zauco, E.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2012, 68 : 40 - 45
  • [48] Laser ablation-laser induced breakdown spectroscopy for the measurement of total elemental concentration in soils
    Pareja, Jhon
    Lopez, Sebastian
    Jaramillo, Daniel
    Hahn, David W.
    Molina, Alejandro
    APPLIED OPTICS, 2013, 52 (11) : 2470 - 2477
  • [49] Simulation of multi-pulse laser ablation for laser-induced breakdown spectroscopy applications
    Povarnitsyn, Mikhail E.
    Levashov, Pavel R.
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2019, 125 (10):
  • [50] Effects of sample surface morphology on laser-induced breakdown spectroscopy
    Yang, Lei
    Zhang, Yanhui
    Zhang, Zi
    Li, Yinchuan
    Xiang, Yong
    Dong, Jingtao
    Wei, Yongqing
    Chang, Songtao
    Lu, Rongsheng
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (08) : 1642 - 1651