Carry-Over Effects of the Membrane Interface Probe

被引:10
|
作者
Bumberger, Jan [1 ]
Radny, Dirk [2 ]
Berndsen, Andreas [3 ]
Goblirsch, Tobias [1 ]
Flachowsky, Johannes [1 ]
Dietrich, Peter [1 ]
机构
[1] UFZ Helmholtz Ctr Environm Res, Helmholtz Ctr Environm Res, Dept Monitoring & Explorat Technol, D-04318 Leipzig, Germany
[2] Tech Univ Berlin, Dept Hydrogeol, D-13355 Berlin, Germany
[3] MPBF Mess & Probenahmetech, D-72401 Haigerloch Gruol, Germany
关键词
D O I
10.1111/j.1745-6584.2011.00879.x
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
The membrane interface probe (MIP) is widely used to characterize the subsurface distribution of volatile organic compounds (VOCs). One problem that arises during MIP application is that disproportionately high MIP signals are obtained after passing source zones which contain mobile or residual phases. This serious problem occurs because of a carry-over effect, in particular caused by compound-specific retention times in the conventional unheated transfer line, commonly used during such an investigation. The objective of this study was to perform a qualitative methodical field evaluation of the carry-over effect of a conventional MIP system with a conventional unheated transfer line. This was achieved by coupling a mobile mass spectrometer to the MIP device. Results obtained were then further compared with those achieved using a laser induced fluorescence (LIF) system. Because of this coupling, time- and depth-dependent signals for different substances became known. Field evaluation data obtained showed complex superpositions of compounds with MIP system results. As a result of this superposition, MIP signals from the saturated zone beneath the source zone (zone with free and/or residual phase) are blurred and are therefore not representative of particular depths. However, utilizing multidirectional probing alongside conventional MIP probing (forwards and backwards), it was possible to detect the upper and lower phase boundary of the source zone. These MIP results correlated excellently with the LIF results. An important conclusion that can be drawn from the field investigation is that coupling a mobile mass spectrometer to the MIP system enables advanced MIP signal interpretation to be successfully achieved.
引用
收藏
页码:578 / 584
页数:7
相关论文
共 50 条
  • [31] CARRY-OVER WITH SPEECH PALS
    MARQUARDT, E
    [J]. JOURNAL OF SPEECH AND HEARING DISORDERS, 1959, 24 (02): : 154 - 157
  • [32] THE CARRY-OVER EFFECT OF ADVERTISING
    TULL, DS
    [J]. JOURNAL OF MARKETING, 1965, 29 (02) : 46 - 53
  • [33] BALANCING CARRY-OVER EFFECTS IN ROUND ROBIN TOURNAMENTS
    RUSSELL, KG
    [J]. BIOMETRIKA, 1980, 67 (01) : 127 - 131
  • [34] The bilingual carry-over effect
    Hoosain, R
    Poon, WM
    [J]. PSYCHOLOGIA, 1997, 40 (01) : 51 - 55
  • [35] CARRY-OVER IN AUTOMATIC ANALYZERS
    BROUGHTON, PMG
    [J]. JOURNAL OF AUTOMATIC CHEMISTRY, 1984, 6 (02): : 94 - 95
  • [36] Formation and carry-over of mycotoxins
    Piva, G
    Pietri, A
    Moschini, M
    [J]. RESIDUES OF VETERINARY DRUGS AND MYCOTOXINS IN ANIMAL PRODUCTS: NEW METHODS FOR RISK ASSESSMENT AND QUALITY CONTROL, 1996, : 149 - 158
  • [37] Influences of Carry-Over Effects Across Scales on Mediation Analyses
    Jin, Kuan-Yu
    Wu, Yi-Jhen
    Chiu, Ming Ming
    [J]. MEASUREMENT-INTERDISCIPLINARY RESEARCH AND PERSPECTIVES, 2024,
  • [38] EFFECTS OF SPRAY CARRY-OVER ON DROPLET REMOVAL IN A CENTRIFUGAL SEPARATOR
    KOSENKOV, VN
    KHAIDAROV, GG
    [J]. JOURNAL OF APPLIED CHEMISTRY OF THE USSR, 1987, 60 (09): : 1849 - 1853
  • [39] Carry-over effects of CCC-applications in pear orchards
    Maas, Frank
    [J]. Proceedings of the Xth International Symposium on Plant Bioregulators in Fruit Production, 2006, (727): : 125 - 132
  • [40] Design and analysis of factorial sensory experiments with carry-over effects
    Durier, C
    Monod, H
    Bruetschy, A
    [J]. FOOD QUALITY AND PREFERENCE, 1997, 8 (02) : 141 - 149