VERIFICATION AND VALIDATION OF ONE-DIMENSIONAL FLOW-ACCELERATED CORROSION EVALUATION CODE

被引:4
|
作者
Suzuki, Hiroaki [1 ]
Uchida, Shunsuke [1 ]
Naitoh, Masanori [1 ]
Okada, Hidetoshi [1 ]
Koikari, Souji [1 ]
Nagaya, Yukihiko [2 ]
Nakamura, Akira [2 ]
Koshizuka, Seiichi [3 ]
Lister, Derek H. [4 ]
机构
[1] Inst Appl Energy, Minato Ku, Tokyo 1050001, Japan
[2] Inst Nucl Safety Syst Inc, Mihama, Fukui 9191205, Japan
[3] Univ Tokyo, Bunkyo Ku, Tokyo 1138656, Japan
[4] Univ New Brunswick, Fredericton, NB E3B 5A3, Canada
关键词
flow-accelerated corrosion; computer program; verification and validation; NUCLEAR-POWER-PLANTS; STATIC ELECTROCHEMICAL ANALYSIS; OXIDE LAYER ANALYSIS; COUPLING ANALYSIS; COOLING SYSTEMS; COMPONENTS; DAMAGE; MODEL;
D O I
10.13182/NT13-A16992
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A six-step procedure based on three-dimensional (3-D) computational fluid dynamics codes and a coupled model of electrochemistry and oxide layer growth models was proposed to estimate local wall thinning due to flow-accelerated corrosion (FAC), and they were applied to evaluate wall-thinning rates, residual lifetimes of the pipes, and applicability of countermeasures against FAC. A verification and validation (V&V) evaluation based on a comparison of calculated and measured wall thinning confirmed that the wall-thinning rate could be predicted with an accuracy within a factor of 2 and that residual wall thicknesses after 1 year of operation could be estimated with an error of <20%. To mitigate one of the disadvantages of the 3-D FAC code, which is the large amount of computational time needed, and to evaluate FAC occurrence probability for entire plant systems, a one-dimensional (1-D) FAC code was developed by applying 1-D mass transfer coefficients and geometrical factors. High-FAC occurrence zones along entire cooling systems and the effects of countermeasures on mitigating the risks could be evaluated within a small amount of computer time. Prior to application of the easy-to-handle FAC code for plant analysis, its accuracy and applicability should be confirmed based on V&V processes. From comparison of maximum wall-thinning rates calculated with the 1-D FAC code, those calculated with the 3-D FAC code, and measured results for experimental loops and secondary piping of an actual pressurized water reactor plant, it was confirmed that the calculated wall-thinning rates agreed with the measured ones within a factor of 2.
引用
收藏
页码:62 / 74
页数:13
相关论文
共 50 条
  • [41] Use of OpenMP to Parallelise a One-dimensional Multiphase Flow Code
    Kalogerakos, Stamatis
    Gourma, Mustapha
    Jia, Ninghong
    [J]. PROCEEDINGS OF THE INTERNATIONAL CONFERENCE OF NUMERICAL ANALYSIS AND APPLIED MATHEMATICS 2014 (ICNAAM-2014), 2015, 1648
  • [42] FLOW AND MASS TRANSFER IN BENDS UNDER FLOW-ACCELERATED CORROSION WALL THINNING CONDITIONS
    Pietralik, John M.
    Schefski, Chris S.
    [J]. ICONE 17: PROCEEDINGS OF THE 17TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, VOL 1, 2009, : 493 - 501
  • [43] DEVELOPMENT OF PREDICTION TOOL FOR FLOW-ACCELERATED CORROSION: (2) EVALUATION OF GEOMETRY FACTOR FOR VARIOUS PIPE COMPONENTS
    Yuasa, Tomohisa
    Watanabe, Shun
    Yoneda, Kimitoshi
    Morita, Ryo
    [J]. PROCEEDINGS OF ASME 2023 PRESSURE VESSELS & PIPING CONFERENCE, PVP2023, VOL 6, 2023,
  • [44] Flow and Mass Transfer in Bends Under Flow-Accelerated Corrosion Wall Thinning Conditions
    Pietralik, John M.
    Schefski, Chris S.
    [J]. JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2011, 133 (01):
  • [45] Verification and refinement of the one-dimensional analysis code for the integrated steam generators in an SFR
    Kim, Seyun
    Eoh, Jae-Hyuk
    Choi, Bo Young
    Kim, Seong-O
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2008, 35 (01) : 12 - 20
  • [46] Effect of ethanol amine injection on flow-accelerated corrosion of PWR secondary systems
    Fukumura, Takuya
    Fukuya, Koji
    Arioka, Koji
    [J]. Transactions of the Atomic Energy Society of Japan, 2010, 9 (03) : 318 - 329
  • [47] Comparative Study on Flow-Accelerated Corrosion and Erosion-Corrosion at a 90° Carbon Steel Bend
    Zeng, Li
    Chen, Geng
    Chen, Hanxin
    [J]. MATERIALS, 2020, 13 (07)
  • [48] The Influence of Steel Alloying on the Flow-Accelerated Corrosion of Steels in the Loops of NPPs with VVERs
    Kritskii, V. G.
    Gavrilov, A. V.
    Prokhorov, N. A.
    Motkova, E. A.
    [J]. THERMAL ENGINEERING, 2022, 69 (08) : 624 - 631
  • [49] The Influence of Steel Alloying on the Flow-Accelerated Corrosion of Steels in the Loops of NPPs with VVERs
    V. G. Kritskii
    A. V. Gavrilov
    N. A. Prokhorov
    E. A. Motkova
    [J]. Thermal Engineering, 2022, 69 : 624 - 631
  • [50] Predictive Study of Flow-Accelerated Corrosion Characteristic Parameters Based on the Neural Network
    Gu, Yong
    Wang, Mingxiang
    Jin, Haozhe
    [J]. CORROSION, 2022, 78 (08) : 751 - 764