VERIFICATION AND VALIDATION OF ONE-DIMENSIONAL FLOW-ACCELERATED CORROSION EVALUATION CODE

被引:4
|
作者
Suzuki, Hiroaki [1 ]
Uchida, Shunsuke [1 ]
Naitoh, Masanori [1 ]
Okada, Hidetoshi [1 ]
Koikari, Souji [1 ]
Nagaya, Yukihiko [2 ]
Nakamura, Akira [2 ]
Koshizuka, Seiichi [3 ]
Lister, Derek H. [4 ]
机构
[1] Inst Appl Energy, Minato Ku, Tokyo 1050001, Japan
[2] Inst Nucl Safety Syst Inc, Mihama, Fukui 9191205, Japan
[3] Univ Tokyo, Bunkyo Ku, Tokyo 1138656, Japan
[4] Univ New Brunswick, Fredericton, NB E3B 5A3, Canada
关键词
flow-accelerated corrosion; computer program; verification and validation; NUCLEAR-POWER-PLANTS; STATIC ELECTROCHEMICAL ANALYSIS; OXIDE LAYER ANALYSIS; COUPLING ANALYSIS; COOLING SYSTEMS; COMPONENTS; DAMAGE; MODEL;
D O I
10.13182/NT13-A16992
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A six-step procedure based on three-dimensional (3-D) computational fluid dynamics codes and a coupled model of electrochemistry and oxide layer growth models was proposed to estimate local wall thinning due to flow-accelerated corrosion (FAC), and they were applied to evaluate wall-thinning rates, residual lifetimes of the pipes, and applicability of countermeasures against FAC. A verification and validation (V&V) evaluation based on a comparison of calculated and measured wall thinning confirmed that the wall-thinning rate could be predicted with an accuracy within a factor of 2 and that residual wall thicknesses after 1 year of operation could be estimated with an error of <20%. To mitigate one of the disadvantages of the 3-D FAC code, which is the large amount of computational time needed, and to evaluate FAC occurrence probability for entire plant systems, a one-dimensional (1-D) FAC code was developed by applying 1-D mass transfer coefficients and geometrical factors. High-FAC occurrence zones along entire cooling systems and the effects of countermeasures on mitigating the risks could be evaluated within a small amount of computer time. Prior to application of the easy-to-handle FAC code for plant analysis, its accuracy and applicability should be confirmed based on V&V processes. From comparison of maximum wall-thinning rates calculated with the 1-D FAC code, those calculated with the 3-D FAC code, and measured results for experimental loops and secondary piping of an actual pressurized water reactor plant, it was confirmed that the calculated wall-thinning rates agreed with the measured ones within a factor of 2.
引用
收藏
页码:62 / 74
页数:13
相关论文
共 50 条
  • [31] Development of flow-accelerated corrosion prediction method (2) Modeling and validation with thinning rate profile data
    Yoneda, Kimitoshi
    Fujiwara, Kazutoshi
    Morita, Ryo
    Inada, Fumio
    [J]. MECHANICAL ENGINEERING JOURNAL, 2018, 5 (01):
  • [32] Flow-Accelerated Corrosion Wear of Power-Generating Equipment: Investigations, Prediction and Prevention: Part 3. Managing the Flow-Accelerated Corrosion of Pipelines and Equipment
    Tomarov G.V.
    Shipkov A.A.
    Aflitonov D.V.
    [J]. Thermal Engineering, 2018, 65 (9) : 651 - 659
  • [33] COMBUSTION OF HYDROGEN IN A SUPERSONIC AIR-FLOW - DEVELOPMENT AND VALIDATION OF A ONE-DIMENSIONAL NUMERICAL CODE
    PERAULT, L
    KAGEYAMA, T
    [J]. REVUE GENERALE DE THERMIQUE, 1994, 33 (394): : 580 - 585
  • [34] Effects of local velocity components on flow-accelerated corrosion at 90° elbow
    Si, Xiaodong
    Zhang, Rui
    Xu, Qi
    Zhou, Keyi
    [J]. MATERIALS RESEARCH EXPRESS, 2019, 6 (01):
  • [35] Influence of Iron Boride Coating on Flow-Accelerated Corrosion of Carbon Steel
    Medvedovski, Eugene
    Roghanizad, Mohsen
    Leal Mendoza, Gerardo
    Cai, Wenjun
    Hendricks, Robert W.
    [J]. ADVANCED ENGINEERING MATERIALS, 2020, 22 (08)
  • [36] Atomic-Scale Insights into Flow-Accelerated Corrosion of Carbon Steel
    Hur, Do-Haeng
    Han, Jeoh
    Lee, Young-Kook
    [J]. METALS, 2024, 14 (04)
  • [37] FLOW-ACCELERATED CORROSION SUSCEPTIBILITY PREDICTION OF RECIRCULATING STEAM GENERATOR INTERNALS
    Pietralik, John M.
    Heppner, Kevin L.
    [J]. ICONE16: PROCEEDING OF THE 16TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2008, VOL 1, 2008, : 657 - 664
  • [38] EXPLOITATION OF ACOUSTIC EMISSION METHOD FOR FLOW-ACCELERATED CORROSION (FAC) MONITORING
    Koula, Vaclav
    Drab, Martin
    Havavka, Michal
    [J]. NDE FOR SAFETY: DEFEKTOSKOPIE 2010, 2010, : 333 - 336
  • [39] A statistical approach to estimate state variables in flow-accelerated corrosion problems
    de Moura, Bruno Furtado
    da Silva, Wellington Betencurte
    Severo de Macedo, Marcelo Camargo
    Martins, Marcio Ferreira
    [J]. INVERSE PROBLEMS IN SCIENCE AND ENGINEERING, 2018, 26 (07) : 966 - 995
  • [40] One-dimensional Models of Particles Flow and Infocommunication Methods of Verification
    Buslaev, Alexander P.
    Gorodnichev, Mikhail G.
    Provorov, Andrew V.
    [J]. 2014 INTERNATIONAL CONFERENCE ON COMPUTATIONAL SCIENCE AND COMPUTATIONAL INTELLIGENCE (CSCI), VOL 1, 2014, : 253 - 256