VERIFICATION AND VALIDATION OF ONE-DIMENSIONAL FLOW-ACCELERATED CORROSION EVALUATION CODE

被引:4
|
作者
Suzuki, Hiroaki [1 ]
Uchida, Shunsuke [1 ]
Naitoh, Masanori [1 ]
Okada, Hidetoshi [1 ]
Koikari, Souji [1 ]
Nagaya, Yukihiko [2 ]
Nakamura, Akira [2 ]
Koshizuka, Seiichi [3 ]
Lister, Derek H. [4 ]
机构
[1] Inst Appl Energy, Minato Ku, Tokyo 1050001, Japan
[2] Inst Nucl Safety Syst Inc, Mihama, Fukui 9191205, Japan
[3] Univ Tokyo, Bunkyo Ku, Tokyo 1138656, Japan
[4] Univ New Brunswick, Fredericton, NB E3B 5A3, Canada
关键词
flow-accelerated corrosion; computer program; verification and validation; NUCLEAR-POWER-PLANTS; STATIC ELECTROCHEMICAL ANALYSIS; OXIDE LAYER ANALYSIS; COUPLING ANALYSIS; COOLING SYSTEMS; COMPONENTS; DAMAGE; MODEL;
D O I
10.13182/NT13-A16992
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A six-step procedure based on three-dimensional (3-D) computational fluid dynamics codes and a coupled model of electrochemistry and oxide layer growth models was proposed to estimate local wall thinning due to flow-accelerated corrosion (FAC), and they were applied to evaluate wall-thinning rates, residual lifetimes of the pipes, and applicability of countermeasures against FAC. A verification and validation (V&V) evaluation based on a comparison of calculated and measured wall thinning confirmed that the wall-thinning rate could be predicted with an accuracy within a factor of 2 and that residual wall thicknesses after 1 year of operation could be estimated with an error of <20%. To mitigate one of the disadvantages of the 3-D FAC code, which is the large amount of computational time needed, and to evaluate FAC occurrence probability for entire plant systems, a one-dimensional (1-D) FAC code was developed by applying 1-D mass transfer coefficients and geometrical factors. High-FAC occurrence zones along entire cooling systems and the effects of countermeasures on mitigating the risks could be evaluated within a small amount of computer time. Prior to application of the easy-to-handle FAC code for plant analysis, its accuracy and applicability should be confirmed based on V&V processes. From comparison of maximum wall-thinning rates calculated with the 1-D FAC code, those calculated with the 3-D FAC code, and measured results for experimental loops and secondary piping of an actual pressurized water reactor plant, it was confirmed that the calculated wall-thinning rates agreed with the measured ones within a factor of 2.
引用
收藏
页码:62 / 74
页数:13
相关论文
共 50 条
  • [1] RISK EVALUATION OF FLOW-ACCELERATED CORROSION BASED ON ONE-DIMENSIONAL FAC CODE
    Suzuki, Hiroaki
    Uchida, Shunsuke
    Naitoh, Masanori
    Okada, Hidetoshi
    Koikari, Soji
    Hasegawa, Kunio
    Kojima, Fumio
    Koshizuka, Seiichi
    Lister, Derek H.
    [J]. NUCLEAR TECHNOLOGY, 2013, 183 (02) : 194 - 209
  • [2] VERIFICATION AND VALIDATION OF EVALUATION PROCEDURES FOR LOCAL WALL THINNING DUE TO FLOW-ACCELERATED CORROSION AND LIQUID DROPLET IMPINGEMENT
    Uchida, Shunsuke
    Naitoh, Masanori
    Okada, Hidetoshi
    Ohira, Taku
    Koshizuka, Seiichi
    Lister, Derek H.
    [J]. NUCLEAR TECHNOLOGY, 2012, 178 (03) : 280 - 297
  • [3] Evaluation of the proximity effect on flow-accelerated corrosion
    Ahmed, Wael H.
    [J]. ANNALS OF NUCLEAR ENERGY, 2010, 37 (04) : 598 - 605
  • [4] Beware of Flow-Accelerated Corrosion
    Buecker, Brad
    [J]. CHEMICAL ENGINEERING, 2013, 120 (03) : 38 - 40
  • [5] Flow-accelerated corrosion & cavitation
    Jonas, Otakar
    [J]. Water and Wastes Digest, 2009, 49 (01): : 22 - 24
  • [6] The COMSY - Code for the Detecting of Piping Degradation Due to Flow-Accelerated Corrosion
    Zander, Andre
    Nopper, Helmut
    [J]. PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE - 2008, VOL 6, PT A AND B, 2009, : 905 - 910
  • [7] MODELLING MATERIAL EFFECTS IN FLOW-ACCELERATED CORROSION
    Phromwong, P.
    Lister, Derek
    Uchida, S.
    [J]. 15TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL DEGRADATION OF MATERIALS IN NUCLEAR POWER SYSTEMS-WATER REACTORS, 2011, : 925 - 937
  • [8] Flow-Accelerated Corrosion in Gas Compression Piping
    El-Sayed, Mohamed Hanafy
    [J]. MATERIALS PERFORMANCE, 2015, 54 (02) : 46 - 50
  • [9] Flow-accelerated corrosion: A critical issue revisited
    Buecker, Brad
    [J]. POWER ENGINEERING, 2007, 111 (07) : 20 - +
  • [10] Development and Verification of a One-Dimensional Ablation Code Including Pyrolysis Gas Flow
    Amar, A. J.
    Blackwell, B. F.
    Edwards, J. R.
    [J]. JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2009, 23 (01) : 59 - 71