The Role of the Attenuation Correction by ECG-GATED Myocardial Perfusion SPECT/CT

被引:0
|
作者
Radacsi, A. [1 ]
Olbrich, Z. [1 ]
Balogh, I. [2 ]
Ronaszeki, A. [3 ]
Ronaszeki, A. [3 ]
机构
[1] Euromed Peterfy Hosp, Budapest, Hungary
[2] Euromedic, Budapest, Hungary
[3] Peterfy Hosp, Budapest, Hungary
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
P0833
引用
收藏
页码:S538 / S539
页数:2
相关论文
共 50 条
  • [31] The impact of hypertension on diastolic left ventricular function, evaluated by quantitative ECG-gated myocardial perfusion SPECT
    Sayed, Mohamed H. M.
    Eltayeb, A. O.
    Farghaly, Hussein R. S.
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2015, 46 (03): : 599 - 603
  • [32] Assessment of left ventricular mechanical dyssynchrony by phase analysis of ECG-gated SPECT myocardial perfusion imaging
    Ji Chen
    Maureen M. Henneman
    Mark A. Trimble
    Jeroen J. Bax
    Salvador Borges-Neto
    Ami E. Iskandrian
    Kenneth J. Nichols
    Ernest V. Garcia
    Journal of Nuclear Cardiology, 2008, 15 : 127 - 136
  • [33] Diagnostic accuracy of rest/stress ECG-gated Rb-82 myocardial perfusion PET: Comparison with ECG-gated Tc-99m sestamibi SPECT
    Bateman, TM
    Heller, GV
    McGhie, AI
    Friedman, JD
    Case, JA
    Bryngelson, JR
    Hertenstein, GK
    Moutray, KL
    Reid, K
    Cullom, SJ
    JOURNAL OF NUCLEAR CARDIOLOGY, 2006, 13 (01) : 24 - 33
  • [34] Diagnostic accuracy of rest/stress ECG-gated Rb-82 myocardial perfusion PET: Comparison with ECG-gated Tc-99m sestamibi SPECT
    Timothy M. Bateman
    Gary V. Heller
    A. Iain McGhie
    John D. Friedman
    James A. Case
    Jan R. Bryngelson
    Ginger K. Hertenstein
    Kelly L. Moutray
    Kimberly Reid
    S. James Cullom
    Journal of Nuclear Cardiology, 2006, 13 : 24 - 33
  • [35] Assessment of Septal Perfusion with ECG-gated Myocardial Perfusion Scintigraphy in LBBB Patients
    Nikoletic, K.
    Lucic, S.
    Peter, A.
    Stojiljkovic, J.
    Kmezic-Grujin, J.
    Stefanovic, M.
    Jovelic, A.
    Tadic, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S380 - S380
  • [36] ECG-gated pinhole SPECT in mice
    Wu, MC
    Tang, HR
    Gao, DW
    Ido, A
    O'Connell, JW
    Hasegawa, BH
    Dae, ME
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1318 - 1322
  • [37] Attenuation correction of thallium myocardial perfusion SPECT
    Ryan, PJ
    Hausenlot, D
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (08): : 1232 - 1232
  • [38] Respiratory Motion Detection and Correction in ECG-Gated SPECT: a New Approach
    Bitarafan, Ahmad
    Rajabi, Hossein
    Gruy, Bornhard
    Rustgou, Feridoon
    Sharafi, Ali Akbar
    Firoozabady, Hasan
    Yaghoobi, Nahid
    Malek, Hadi
    Pirich, Christian
    Langesteger, Werner
    Beheshti, Mohsen
    KOREAN JOURNAL OF RADIOLOGY, 2008, 9 (06) : 490 - 497
  • [39] ECG-gated cardiac CT
    Desjardins, B
    Kazerooni, EA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (04) : 993 - 1010
  • [40] Serial assessment of left ventricular performance at rest and during bicycle exercise by ECG-gated myocardial perfusion SPECT
    Shin-ichiro Kumita
    Keiichi Cho
    Hidenobu Nakajo
    Masahiro Toba
    Kazuyoshi Akiyama
    Yoshimitsu Fukushima
    Sunao Mizumura
    Tatsuo Kumazaki
    Junko Sano
    Kazuo Munakata
    Hiroshi Kishida
    Teruo Takano
    Annals of Nuclear Medicine, 2002, 16 : 329 - 335