Diagnostic accuracy of rest/stress ECG-gated Rb-82 myocardial perfusion PET: Comparison with ECG-gated Tc-99m sestamibi SPECT

被引:340
|
作者
Bateman, TM
Heller, GV
McGhie, AI
Friedman, JD
Case, JA
Bryngelson, JR
Hertenstein, GK
Moutray, KL
Reid, K
Cullom, SJ
机构
[1] Cardiovasc Consultants, PC, Kansas City, MO 64111 USA
[2] Cardiovasc Imaging Technol LLC, Kansas City, MO USA
[3] Mid Amer Heart Inst, Kansas City, MO USA
[4] Hartford Hosp, Henry Low Heart Ctr, Div Cardiol, Hartford, CT 06115 USA
[5] Cedars Sinai Med Ctr, Los Angeles, CA 90048 USA
关键词
single photon emission computed tomography; positron emission tomography; myocardial perfusion imaging;
D O I
10.1016/j.nuclcard.2005.12.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Although single photon emission computed tomography (SPECT) and positron emission tomography (PET) myocardial perfusion imaging (MPI) have evolved considerably over the last decade, there is no recent comparison of diagnostic performance. This study was designed to assess relative image quality, interpretive confidence, and diagnostic accuracy by use of contemporary technology and protocols. Methods and Results. By consensus and without clinical information, 4 experienced nuclear cardiologists interpreted 112 SPECT technetium-99m sestamibi and 112 PET rubidium-82 MPI electrocardiography (ECG)-gated rest/pharmacologic stress studies in patient populations matched by gender, body mass index, and presence and extent of coronary disease. The patients were categorized as having a low likelihood for coronary artery disease (27 in each group) or had coronary angiography within 60 days. SPECT scans were acquired on a Cardio-60 system and PET scans on an ECAT ACCEL scanner. Image quality was excellent for 78% and 79% of rest and stress PET scans, respectively, versus 62% and 62% of respective SPECT scans (both p <.05). An equal percent of PET and SPECT gated images were rated excellent in quality. Interpretations were definitely normal or abnormal for 96% of PET scans versus 81% of SPECT scans (p =.001). Diagnostic accuracy was higher for PET for both stenosis severity thresholds of 70% (89% vs 79%,p =.03) and 50% (87% vs 71%,p =.003) and was higher in men and women, in obese and nonobese patients, and for correct identification of multivessel coronary artery disease. Conclusion. In a large population of matched pharmacologic stress patients, myocardial perfusion PET was superior to SPECT in image quality, interpretive certainty, and diagnostic accuracy.
引用
收藏
页码:24 / 33
页数:10
相关论文
共 50 条
  • [1] Diagnostic accuracy of rest/stress ECG-gated Rb-82 myocardial perfusion PET: Comparison with ECG-gated Tc-99m sestamibi SPECT
    Timothy M. Bateman
    Gary V. Heller
    A. Iain McGhie
    John D. Friedman
    James A. Case
    Jan R. Bryngelson
    Ginger K. Hertenstein
    Kelly L. Moutray
    Kimberly Reid
    S. James Cullom
    Journal of Nuclear Cardiology, 2006, 13 : 24 - 33
  • [2] The prognostic value of ECG-gated SPECT imaging in patients undergoing stress Tc-99m sestamibi myocardial perfusion imaging
    Travin, MI
    Heller, GV
    Johnson, LL
    Katten, D
    Ahlberg, AW
    Isasi, CR
    Kaplan, RC
    Taub, CC
    Demus, D
    JOURNAL OF NUCLEAR CARDIOLOGY, 2004, 11 (03) : 253 - 262
  • [3] The prognostic value of ECG-gated SPECT imaging in patients undergoing stress Tc-99m sestamibi myocardial perfusion imaging
    Mark I. Travin
    Gary V. Heller
    Lynne L. Johnson
    Deborah Katten
    Alan W. Ahlberg
    Carmen R. Isasi
    Robert C. Kaplan
    Cynthia C. Taub
    Diane Demus
    Journal of Nuclear Cardiology, 2004, 11 : 253 - 262
  • [4] Risk stratification of diabetic patients with rest/stress ECG-gated Tc-99m sestamibi SPECT imaging: Significance of mild perfusion abnormalities
    Navare, SM
    Noble, GL
    Ahmed, SU
    Ahlbert, AW
    Katten, DM
    Alexander, LL
    Shaw, LJ
    Boden, WE
    Heller, GV
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 339A - 339A
  • [5] Diagnostic accuracy of simultaneous acquisition dual isotope (rest TI-201/stress sestamibi) ECG-gated myocardial perfusion SPECT
    Bateman, TM
    McGhie, AI
    O'Keefe, JH
    Cullom, SJ
    Moutray, KL
    Gainey, WE
    Alaswad, K
    Case, JA
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 417A - 417A
  • [6] Interaction of age and gender on risk stratification of diabetic patients with rest/stress ECG-gated Tc-99m sestamibi SPECT imaging
    Navare, SM
    Ahmed, SU
    Noble, GL
    Ahlberg, AW
    Katten, DM
    Cyr, G
    Shaw, WJ
    Boden, WE
    Heller, GV
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 339A - 339A
  • [7] Estimation of left ventricular ejection fraction assessed by ECG-gated Tc-99m tetrofosmin radial long axial myocardial SPECT: Comparison with ECG-gated blood pool SPECT.
    Tsujimura, E
    Uehara, T
    Fukuchi, K
    Hasegawa, S
    Ito, Y
    Matsuda, S
    Hashimoto, K
    Yamaguchi, H
    Kusuoka, H
    Hori, M
    Nishimura, T
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 705 - 705
  • [8] The diagnostic and prognostic value of ECG-gated SPECT myocardial perfusion imaging
    Go, V
    Bhatt, MR
    Hendel, RC
    JOURNAL OF NUCLEAR MEDICINE, 2004, 45 (05) : 912 - 921
  • [9] Rapid data acquisition protocol in ECG-gated myocardial perfusion SPECT with Tc-99m-tetrofosmin
    Kumita S.-I.
    Kumazaki T.
    Cho K.
    Mizumura S.
    Kijima T.
    Ishihara M.
    Nakajo H.
    Sano J.
    Tada Y.
    Sakai S.
    Kusama Y.
    Munakata K.
    Annals of Nuclear Medicine, 1998, 12 (2) : 71 - 75
  • [10] Preliminary normal values for left ventricular mechanical synchrony from stress Rb-82 PET myocardial perfusion ECG-gated studies
    Cooke, David
    Esteves, Fabio
    Chen, Ji
    Garcia, Ernest
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50