Diagnostic accuracy of rest/stress ECG-gated Rb-82 myocardial perfusion PET: Comparison with ECG-gated Tc-99m sestamibi SPECT

被引:340
|
作者
Bateman, TM
Heller, GV
McGhie, AI
Friedman, JD
Case, JA
Bryngelson, JR
Hertenstein, GK
Moutray, KL
Reid, K
Cullom, SJ
机构
[1] Cardiovasc Consultants, PC, Kansas City, MO 64111 USA
[2] Cardiovasc Imaging Technol LLC, Kansas City, MO USA
[3] Mid Amer Heart Inst, Kansas City, MO USA
[4] Hartford Hosp, Henry Low Heart Ctr, Div Cardiol, Hartford, CT 06115 USA
[5] Cedars Sinai Med Ctr, Los Angeles, CA 90048 USA
关键词
single photon emission computed tomography; positron emission tomography; myocardial perfusion imaging;
D O I
10.1016/j.nuclcard.2005.12.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Although single photon emission computed tomography (SPECT) and positron emission tomography (PET) myocardial perfusion imaging (MPI) have evolved considerably over the last decade, there is no recent comparison of diagnostic performance. This study was designed to assess relative image quality, interpretive confidence, and diagnostic accuracy by use of contemporary technology and protocols. Methods and Results. By consensus and without clinical information, 4 experienced nuclear cardiologists interpreted 112 SPECT technetium-99m sestamibi and 112 PET rubidium-82 MPI electrocardiography (ECG)-gated rest/pharmacologic stress studies in patient populations matched by gender, body mass index, and presence and extent of coronary disease. The patients were categorized as having a low likelihood for coronary artery disease (27 in each group) or had coronary angiography within 60 days. SPECT scans were acquired on a Cardio-60 system and PET scans on an ECAT ACCEL scanner. Image quality was excellent for 78% and 79% of rest and stress PET scans, respectively, versus 62% and 62% of respective SPECT scans (both p <.05). An equal percent of PET and SPECT gated images were rated excellent in quality. Interpretations were definitely normal or abnormal for 96% of PET scans versus 81% of SPECT scans (p =.001). Diagnostic accuracy was higher for PET for both stenosis severity thresholds of 70% (89% vs 79%,p =.03) and 50% (87% vs 71%,p =.003) and was higher in men and women, in obese and nonobese patients, and for correct identification of multivessel coronary artery disease. Conclusion. In a large population of matched pharmacologic stress patients, myocardial perfusion PET was superior to SPECT in image quality, interpretive certainty, and diagnostic accuracy.
引用
收藏
页码:24 / 33
页数:10
相关论文
共 50 条
  • [21] Assessment of left ventricular volumes utilizing ECG-gated SPECT with Tc-99m MIBI and tetrofosmin.
    Mochizuki, T
    Murase, K
    Tanaka, H
    Nishikawa, T
    Shinbata, H
    Kondoh, T
    Itoh, T
    Tanada, S
    Hamamoto, K
    Tauxe, WN
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 826 - 826
  • [22] Feasibility and diagnostic accuracy of ECG-gated spect myocardial perfusion imaging by a two hours protocol: The myofast study
    Dunet, V.
    Costro, S.
    Sabatier, R.
    Grollier, G.
    Bouvard, G.
    Agostini, D.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S312 - S312
  • [23] EFFECTS OF CHANGES IN MYOCARDIAL WALL THICKENING ON ECG GATED SPECT TC-99M SESTAMIBI IMAGES
    EISNER, RL
    SCHMARKEY, LS
    MARTIN, SE
    WORTHY, M
    PATTERSON, RE
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P96 - P96
  • [24] Evaluation of resolution recovery reconstruction for stress/ECG-gated rest thallium myocardial perfusion scintigraphy
    Reyes, E.
    Chan, M.
    Hossen, M. L.
    Underwood, S. R.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2011, 13 (0A) : A39 - A39
  • [25] Left ventricular function in response to dipyridamole stress: head-to-head comparison between 82Rubidium PET and 99mTc-sestamibi SPECT ECG-gated myocardial perfusion imaging
    Maria Clementina Giorgi
    Jose Claudio Meneghetti
    Jose Soares
    Marisa Izaki
    Andréa Falcão
    Rodrigo Imada
    William Chalela
    Marco Antonio de Oliveira
    Cesar Nomura
    Hein J. Verberne
    European Journal of Nuclear Medicine and Molecular Imaging, 2017, 44 : 876 - 885
  • [26] Left ventricular function in response to dipyridamole stress: head-to-head comparison between 82Rubidium PET and 99mTc-sestamibi SPECT ECG-gated myocardial perfusion imaging
    Giorgi, Maria Clementina
    Meneghetti, Jose Claudio
    Soares, Jose, Jr.
    Izaki, Marisa
    Falcao, Andrea
    Imada, Rodrigo
    Chalela, William
    de Oliveira, Marco Antonio
    Nomura, Cesar
    Verberne, Hein J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 (05) : 876 - 885
  • [27] ECG-gated dual-isotope myocardial SPECT with Tl-201 and Tc-99m-tetrofosmin: Simultaneous assessment of stress/rest myocardial perfusion and rest LV systolic function
    Kumita, S
    Cho, K
    Mizumura, S
    Kijima, T
    Ishihara, M
    Kumazaki, T
    Sano, J
    Kusama, Y
    Munakata, K
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 1433 - 1433
  • [28] Correlation of Left Ventricular Strain Derived From Rb-82 ECG-Gated PET Myocardial Perfusion Imaging vs 2D Echocardiography
    Huang, Jingwen
    Mitchell, Adam
    Garcia, Ernest
    Cooke, David
    Folks, Russell
    Pernetz, Maria
    Piccinelli, Marina
    Nye, Jonathon
    CIRCULATION, 2022, 146
  • [29] Feasibility and diagnostic accuracy of ECG-gated SPECT myocardial perfusion imaging by a two-hour protocol: The Myofast study
    Dunet, V.
    Costo, S.
    Sabatier, R.
    Grollier, G.
    Bouvard, G.
    Agostini, D.
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2010, 34 (04): : 211 - 218
  • [30] Combining dynamic and ECG-gated 82Rb-PET for practical implementation in the clinic
    Sayre, George A.
    Bacharach, Stephen L.
    Dae, Michael W.
    Seo, Youngho
    NUCLEAR MEDICINE COMMUNICATIONS, 2012, 33 (01) : 4 - 13