Iterative image reconstruction for cerebral perfusion CT using a pre-contrast scan induced edge-preserving prior

被引:142
|
作者
Ma, Jianhua [1 ,2 ]
Zhang, Hua [2 ]
Gao, Yang [2 ]
Huang, Jing [2 ]
Liang, Zhengrong [1 ]
Feng, Qianjing [2 ]
Chen, Wufan [2 ]
机构
[1] SUNY Stony Brook, Dept Radiol, Stony Brook, NY 11794 USA
[2] So Med Univ, Dept Biomed Engn, Guangzhou 510515, Guangdong, Peoples R China
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2012年 / 57卷 / 22期
基金
中国国家自然科学基金;
关键词
COMPUTED-TOMOGRAPHY; TEMPORAL RESOLUTION; MICRO-CT; BRAIN; REDUCTION; RESTORATION; PARAMETERS; ALGORITHM; VOLUME;
D O I
10.1088/0031-9155/57/22/7519
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cerebral perfusion x-ray computed tomography (PCT) imaging, which detects and characterizes the ischemic penumbra, and assesses blood-brain barrier permeability with acute stroke or chronic cerebrovascular diseases, has been developed extensively over the past decades. However, due to its sequential scan protocol, the associated radiation dose has raised significant concerns to patients. Therefore, in this study we developed an iterative image reconstruction algorithm based on the maximum a posterior (MAP) principle to yield a clinically acceptable cerebral PCT image with lower milliampere-seconds (mA s). To preserve the edges of the reconstructed image, an edge-preserving prior was designed using a normal-dose pre-contrast unenhanced scan. For simplicity, the present algorithm was termed as 'MAP-ndiNLM'. Evaluations with the digital phantom and the simulated low-dose clinical brain PCT datasets clearly demonstrate that the MAP-ndiNLM method can achieve more significant gains than the existing FBP and MAP-Huber algorithms with better image noise reduction, low-contrast object detection and resolution preservation. More importantly, the MAP-ndiNLM method can yield more accurate kinetic enhanced details and diagnostic hemodynamic parameter maps than the MAP-Huber method.
引用
收藏
页码:7519 / 7542
页数:24
相关论文
共 50 条
  • [31] A edge-preserving minimum cross-entropy algorithm for pet image reconstruction using multiphase level set method
    Zhu, HQ
    Zhou, J
    Shu, HZ
    Luo, LM
    2005 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, VOLS 1-5: SPEECH PROCESSING, 2005, : 469 - 472
  • [32] Dual Energy CT with One Full Scan and a Second Sparse-View Scan Using Structure Preserving Iterative Reconstruction (SPIR)
    Wang, T.
    Zhu, L.
    MEDICAL PHYSICS, 2015, 42 (06) : 3682 - 3682
  • [33] Dual energy CT with one full scan and a second sparse-view scan using structure preserving iterative reconstruction (SPIR)
    Wang, Tonghe
    Zhu, Lei
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (18): : 6684 - 6706
  • [34] Iterative reconstruction for photon-counting CT using prior image constrained total generalized variation
    Niu, Shanzhou
    Zhang, You
    Zhong, Yuncheng
    Liu, Guoliang
    Lu, Shaohui
    Zhang, Xile
    Hu, Shengzhou
    Wang, Tinghua
    Yu, Gaohang
    Wang, Jing
    COMPUTERS IN BIOLOGY AND MEDICINE, 2018, 103 : 167 - 182
  • [35] Adaptive prior image constrained total generalized variation for low-dose dynamic cerebral perfusion CT reconstruction
    Niu, Shanzhou
    Li, Shuo
    Huang, Shuyan
    Liang, Lijing
    Tang, Sizhou
    Wang, Tinghua
    Yu, Gaohang
    Niu, Tianye
    Wang, Jing
    Ma, Jianhua
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2024, 32 (06) : 1429 - 1447
  • [36] Edge-preserving reconstruction from sparse projections of limited-angle computed tomography using l0-regularized gradient prior
    Yu, Wei
    Wang, Chengxiang
    Huang, Min
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (04):
  • [37] Reduction of the Radiation Dose for Multidetector Row CT Angiography of Cerebral Aneurysms Using an Edge-Preserving Adaptive Filter: A Vascular Phantom Study
    Kakeda, S.
    Korogi, Y.
    Ogawa, M.
    Otsubo, K.
    Morishita, Y.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (05) : 827 - 829
  • [38] Iterative Reconstruction for X-Ray Computed Tomography Using Prior-Image Induced Nonlocal Regularization
    Zhang, Hua
    Huang, Jing
    Ma, Jianhua
    Bian, Zhaoying
    Feng, Qianjin
    Lu, Hongbing
    Liang, Zhengrong
    Chen, Wufan
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (09) : 2367 - 2378
  • [39] Reducing Respiratory Motion-Induced Errors in PET and CT Using an Iterative Image-to-Image Reconstruction Algorithm
    Zhong, H.
    Tai, A.
    Morrow, N. V.
    Gore, E. M.
    Li, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E727 - E728
  • [40] Statistical CT reconstruction using region-aware texture preserving regularization learning from prior normal-dose CT image
    Jia, Xiao
    Liao, Yuting
    Zeng, Dong
    Zhang, Hao
    Zhang, Yuanke
    He, Ji
    Bian, Zhaoying
    Wang, Yongbo
    Tao, Xi
    Liang, Zhengrong
    Huang, Jing
    Ma, Jianhua
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (22):