Micro-dislodgement of a self-expanding transcatheter heart valve: Incidence, predictors, and outcomes

被引:3
|
作者
Kim, Won-Keun [1 ,2 ,3 ,4 ]
Renker, Matthias [1 ,2 ,4 ]
Doerr, Oliver [1 ,3 ,4 ]
Nef, Holger [1 ,3 ,4 ]
Fischer-Rasokat, Ulrich [1 ]
Choi, Yeong-Hoon [2 ,4 ]
Hamm, Christian W. [1 ,3 ,4 ]
Charitos, Efstratios [2 ,4 ]
机构
[1] Kerckhoff Heart Ctr, Dept Cardiol, D-61231 Bad Nauheim, Germany
[2] Kerckhoff Heart Ctr, Dept Cardiac Surg, Bad Nauheim, Germany
[3] Justus Liebig Univ Giessen, Dept Cardiol, Giessen, Germany
[4] DZHK German Ctr Cardiovasc Res, Partner Site Rhein Main, Bad Nauheim, Germany
关键词
Self-expanding prosthesis; ACURATE; NEO2; Migration; Positioning; ACURATE NEO PROSTHESIS; IMPLANTATION; EMBOLIZATION; REPLACEMENT;
D O I
10.1016/j.ijcard.2022.04.031
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: Malpositioning of transcatheter heart valves increases the risk of procedural failure. For the ACURATE system, inadvertent movement of the prosthesis to a varying extent is sometimes observed upon full release, but the incidence, mechanisms, and clinical impact of such valve micro-dislodgement (VMD) are poorly understood. The aim of the present study was to assess the incidence, predictors, and clinical outcomes of VMD in an all-comers population that underwent transcatheter aortic valve implantation (TAVI) with the ACURATE neo2 prosthesis (NEO2). Methods: This was a retrospective analysis of 448 consecutive patients who underwent transfemoral TAVI with NEO2 at our institution. VMD was defined as displacement >= 2 mm between the initial position and immediately after valve release as measured on fluoroscopy at the non-coronary cusp. The initial valve position prior to step 2 was categorized using the radiopaque marker band (RMB) relative to the annular plane. In addition, further anatomical and procedural characteristics were assessed. Results: A total of 68 (15.2%) cases with VMD were identified. A larger cover index, higher RMB position, partial detachment of the lower crown, and severe parallax prior to deployment were independent predictors of VMD, whereas a position of the delivery system in the outer curvature was protective against VMD. Among patients with VMD, the rates of valvular malpositioning and thus technical failure (VARC-3) were higher, but mean transprosthetic gradients were lower. Conclusions: VMD occurs in a notable proportion of transfemoral TAVI cases with NEO2 and is associated with more frequent technical failure of the procedure.
引用
收藏
页码:77 / 82
页数:6
相关论文
共 50 条
  • [31] Incidence rate and predictors of permanent pacemaker implantation after transcatheter aortic valve implantation with self-expanding CoreValve prosthesis
    Conti, S.
    Pruiti, G. P.
    Capodanno, D.
    Puzzangara, E.
    Di Grazia, A.
    Ussia, G. P.
    Tamburino, C.
    Calvi, V.
    EUROPEAN HEART JOURNAL, 2011, 32 : 940 - 940
  • [32] Incidence rate and predictors of permanent pacemaker implantation after transcatheter aortic valve implantation with self-expanding CoreValve prosthesis
    Calvi, Valeria
    Conti, Sergio
    Pruiti, Giusi Paola
    Capodanno, Davide
    Puzzangara, Euglena
    Tempio, Donatella
    Di Grazia, Angelo
    Ussia, Gian Paolo
    Tamburino, Corrado
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2012, 34 (02) : 189 - 195
  • [33] Transcatheter tricuspid valve replacement with a self-expanding bioprosthesis
    Colli, Andrea
    Gerosa, Gino
    Bartus, Krzysztof
    Tarantini, Giuseppe
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 156 (03): : 1064 - 1066
  • [34] Self-Expanding Prostheses for Transcatheter Aortic Valve Replacement
    Kumar, Robert
    Latib, Azeem
    Colombo, Antonio
    Ruiz, Carlos E.
    PROGRESS IN CARDIOVASCULAR DISEASES, 2014, 56 (06) : 596 - 609
  • [35] Sizing for self-expanding transcatheter aortic valve implantation
    Jilaihawi, Hasan
    Zhao, Zhen-Gang
    Williams, Mathew
    EUROINTERVENTION, 2018, 14 (05) : 490 - 493
  • [36] Transcatheter aortic valve implantation with the NVT Allegra transcatheter heart valve system: first-in-human experience with a novel self-expanding transcatheter heart valve
    Wenaweser, Peter
    Stortecky, Stefan
    Schuetz, Torsten
    Praz, Fabien
    Gloekler, Steffen
    Windecker, Stephan
    Elsaesser, Albrecht
    EUROINTERVENTION, 2016, 12 (01) : 71 - 77
  • [37] Rescuing from conduction disturbances with recapturable self-expanding transcatheter heart valve system
    Ohno, Yohei
    Sakai, Katsuaki
    Nakazawa, Gaku
    Ikari, Yuji
    EUROPEAN HEART JOURNAL, 2020, 41 (20)
  • [38] Impact of different in vitro models on functional performance of the self-expanding transcatheter heart valve
    Sadat, Najla
    Lojenburg, John Habakuk
    Scharfschwerdt, Michael
    Fujta, Buntaro
    Ensminger, Stephan
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2023, 64 (04)
  • [39] Implantation of a novel self-expanding transcatheter heart valve in a highly calcified aortic annulus
    Rodriguez-Olivares, Ramon
    Salido-Tahoces, Luisa
    Ayala Carbonero, Ana
    Hernandez-Antolin, Rosana
    Zamorano-Gomez, Jose L.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2018, 19 (05) : 589 - 589
  • [40] Self-expanding transcatheter aortic valve implantation for degenerated mitroflow bioprosthesis: early outcomes
    Pascual Calleja, I.
    Avanzas, P.
    Hernandez-Vaquero, D.
    Diaz, R.
    Padron, R.
    Lorca, R.
    Leon, V.
    Moris, C.
    EUROPEAN HEART JOURNAL, 2018, 39 : 445 - 446