Micro-dislodgement of a self-expanding transcatheter heart valve: Incidence, predictors, and outcomes

被引:3
|
作者
Kim, Won-Keun [1 ,2 ,3 ,4 ]
Renker, Matthias [1 ,2 ,4 ]
Doerr, Oliver [1 ,3 ,4 ]
Nef, Holger [1 ,3 ,4 ]
Fischer-Rasokat, Ulrich [1 ]
Choi, Yeong-Hoon [2 ,4 ]
Hamm, Christian W. [1 ,3 ,4 ]
Charitos, Efstratios [2 ,4 ]
机构
[1] Kerckhoff Heart Ctr, Dept Cardiol, D-61231 Bad Nauheim, Germany
[2] Kerckhoff Heart Ctr, Dept Cardiac Surg, Bad Nauheim, Germany
[3] Justus Liebig Univ Giessen, Dept Cardiol, Giessen, Germany
[4] DZHK German Ctr Cardiovasc Res, Partner Site Rhein Main, Bad Nauheim, Germany
关键词
Self-expanding prosthesis; ACURATE; NEO2; Migration; Positioning; ACURATE NEO PROSTHESIS; IMPLANTATION; EMBOLIZATION; REPLACEMENT;
D O I
10.1016/j.ijcard.2022.04.031
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: Malpositioning of transcatheter heart valves increases the risk of procedural failure. For the ACURATE system, inadvertent movement of the prosthesis to a varying extent is sometimes observed upon full release, but the incidence, mechanisms, and clinical impact of such valve micro-dislodgement (VMD) are poorly understood. The aim of the present study was to assess the incidence, predictors, and clinical outcomes of VMD in an all-comers population that underwent transcatheter aortic valve implantation (TAVI) with the ACURATE neo2 prosthesis (NEO2). Methods: This was a retrospective analysis of 448 consecutive patients who underwent transfemoral TAVI with NEO2 at our institution. VMD was defined as displacement >= 2 mm between the initial position and immediately after valve release as measured on fluoroscopy at the non-coronary cusp. The initial valve position prior to step 2 was categorized using the radiopaque marker band (RMB) relative to the annular plane. In addition, further anatomical and procedural characteristics were assessed. Results: A total of 68 (15.2%) cases with VMD were identified. A larger cover index, higher RMB position, partial detachment of the lower crown, and severe parallax prior to deployment were independent predictors of VMD, whereas a position of the delivery system in the outer curvature was protective against VMD. Among patients with VMD, the rates of valvular malpositioning and thus technical failure (VARC-3) were higher, but mean transprosthetic gradients were lower. Conclusions: VMD occurs in a notable proportion of transfemoral TAVI cases with NEO2 and is associated with more frequent technical failure of the procedure.
引用
收藏
页码:77 / 82
页数:6
相关论文
共 50 条
  • [21] A novel self-expanding transcatheter heart valve: Shaping the story beyond accuracy
    Seth, Ashok
    Kumar, Vijay
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2019, 94 (06) : 793 - 794
  • [22] 30-Day Clinical Outcomes of a Self-Expanding Transcatheter Aortic Valve
    Reardon, Michael J.
    Chehab, Bassem
    Smith, Dave
    Walton, Antony S.
    Worthley, Stephen G.
    Manoharan, Ganesh
    Sultan, Ibrahim
    Yong, Gerald
    Harrington, Katherine
    Mahoney, Paul
    Kleiman, Neal
    Makkar, Raj R.
    Fontana, Gregory
    DeLago, Augustin
    Ramana, Ravi K.
    Bates, Nicholas
    Sondergaard, Lars
    JACC-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (06) : 681 - 689
  • [23] Clinical Outcomes at 1 Year with a Repositionable Self-Expanding Transcatheter Aortic Valve
    Manoharan, Ganesh
    Walton, Antony
    Brecker, Stephen
    Pasupati, Sanjeevan
    Blackman, Daniel J.
    Meredith, Ian T.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B45 - B46
  • [24] Choosing a Self-Expanding Transcatheter Heart Valve in 2018 Is it Worth it to "Go PRO"?
    Sinning, Jan-Malte
    Sedaghat, Alexander
    JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (22) : 2323 - 2325
  • [25] Incidence, Predictor, and Clinical Outcomes of Multiple Resheathing With Self-Expanding Valves During Transcatheter Aortic Valve Replacement
    Bernardi, Fernando L. M.
    Rodes-Cabau, Josep
    Tirado-Conte, Gabriela
    Amat Santos, Ignacio J.
    Plachtzik, Claudia
    Cura, Fernando
    Sztejfman, Matias
    Mangione, Fernanda M.
    Tumeleiro, Rogerio
    Cardozo Esteves, Vinicius Borges
    Pessoa de Melo, Eduardo Franca
    Alcocer Chauvet, Alejandro
    Fuchs, Felipe
    Sarmento-Leite, Rogerio
    de Campos Martins, Estevao Carvalho
    Nombela-Franco, Luis
    Raul Delgado-Arana, Jose
    Bocksch, Wolfgang
    Lamelas, Pablo
    Giuliani, Carlos
    Campanha-Borges, Diego Carter
    Mangione, Jose A.
    de Brito Jr, Fabio Sandoli
    Abizaid, Alexandre C.
    Ribeiro, Henrique B.
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2021, 10 (18):
  • [26] Generational Differences in Outcomes of Self-Expanding Valves for Transcatheter Aortic Valve Replacement
    Loewenstein, Itamar
    Merdler, Ilan
    Hochstadt, Aviram
    Zahler, David
    Finkelstein, Ariel
    Banai, Shmuel
    Topilsky, Yan
    Halkin, Amir
    Konigstein, Maayan
    Bazan, Shmuel
    Barbash, Issy
    Segev, Amit
    Guetta, Victor
    Danenberg, Haim
    Planner, David
    Orvin, Katia
    Assa-Vaknin, Hana
    Assali, Abid
    Kornowski, Ran
    Steinvil, Arie
    JOURNAL OF INVASIVE CARDIOLOGY, 2022, 34 (04): : E326 - E333
  • [27] INCIDENCE, PREDICTOR AND CLINICAL OUTCOMES OF MULTIPLE RESHEATHING WITH SELF-EXPANDING VALVES DURING TRANSCATHETER AORTIC VALVE REPLACEMENT
    Bernardi, Fernando
    Rodes-Cabau, Josep
    Tirado-Conte, Gabriela
    Santos, Ignacio Amat
    Plachtzik, Claudia
    Cura, Fernando
    Sztejfman, Matias
    Mangione, Fernanda
    Tumeleiro, Rogerio
    Esteves, Vinicius
    de Mello, Eduardo Pessoa
    Chauvet, Alejandro
    Fuchs, Felipe
    Sarmento-Leite, Rogerio
    Martins, Estevao
    Nombela-Franco, Luis
    Delgado-Arana, Jose Raul
    Bocksch, Wolfgang
    Lamelas, Pablo
    Giuliani, Carlos
    Cristovao, Salvador
    Campanha-Borges, Diego Carter
    de Brito, Fabio Sandoli, Jr.
    Abizaid, Alexandre
    Ribeiro, Henrique
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (18) : 923 - 923
  • [28] Transcatheter aortic valve implantation in large annuli: incidence and predictors of specific adverse events with the largest self-expanding device
    Veulemans, V.
    Hellhammer, K.
    Maier, O.
    Klein, K.
    Afzal, S.
    Piayda, K.
    Jung, C.
    Westenfeld, R.
    Kelm, M.
    Zeus, T.
    EUROPEAN HEART JOURNAL, 2019, 40 : 2341 - 2341
  • [29] Incidence rate and predictors of permanent pacemaker implantation after transcatheter aortic valve implantation with self-expanding CoreValve prosthesis
    Valeria Calvi
    Sergio Conti
    Giusi Paola Pruiti
    Davide Capodanno
    Euglena Puzzangara
    Donatella Tempio
    Angelo Di Grazia
    Gian Paolo Ussia
    Corrado Tamburino
    Journal of Interventional Cardiac Electrophysiology, 2012, 34 : 189 - 195
  • [30] Aortic Migration of a Self-expanding Transcatheter Heart Valve During Intended Bioprosthetic Valve Fracture
    Harvey, James E.
    Nicholson, William J.
    Burlingame, Mark W.
    Theodos, Gus
    Chhatriwalla, Adnan K.
    Allen, Keith B.
    Tolerico, Paul T.
    STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM, 2019, 3 (03): : 255 - 257