A Simplified Technique for solving the Transfer Problem of Implant-Supported Fixed Partial Dentures for Patients With Microstomia

被引:1
|
作者
Uludag, Bulent [1 ]
Polat, Serdar [1 ]
Sahin, Volkan [1 ]
Tokar, Emre [1 ]
Ertug, Omer [1 ]
机构
[1] Ankara Univ, TR-06100 Ankara, Turkey
关键词
microstomia; implant-supported fixed partial denture; impression; DYSTROPHIC EPIDERMOLYSIS-BULLOSA; CLINICAL REPORT; EDENTULOUS PATIENT; SCLERODERMA; TRAY;
D O I
10.1563/AAID-JOI-D-11-00021
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Techniques for treating a fully or partially edentulous patient with microstomia have been developed to overcome the challenge of accessing the oral cavity. Management of the problems associated with providing implant-supported fixed partial dentures for patients with microstomia has not been well reported. This article describes a solution for the transfer problem that occurs when making an impression of an implant-supported fixed partial dentures for patients with microstomia.
引用
收藏
页码:169 / 171
页数:3
相关论文
共 50 条
  • [41] Comparison of the prognosis of the remaining teeth between implant-supported fixed prostheses and removable partial dentures in partially edentulous patients: A retrospective study
    Yamada, Ryo
    Nogawa, Toshifumi
    Takayama, Yoshiyuki
    Iwata, Kai
    Saito, Masayasu
    Yokoyama, Atsuro
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2022, 24 (01) : 83 - 93
  • [42] The effect of implant-supported removable partial dentures on oral health quality of life
    Gates, W. Day, III
    Cooper, Lyndon F.
    Sanders, Anne E.
    Reside, Glenn J.
    De Kok, Ingeborg J.
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (02) : 207 - 213
  • [43] Influence of rigidity of retainers on dynamic behavior of implant-supported removable partial dentures
    Nogawa, Toshifumi
    Saito, Masayasu
    Murashima, Naomichi
    Takayama, Yoshiyuki
    Yokoyama, Atsuro
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2020, 6 (01)
  • [44] Influence of rigidity of retainers on dynamic behavior of implant-supported removable partial dentures
    Toshifumi Nogawa
    Masayasu Saito
    Naomichi Murashima
    Yoshiyuki Takayama
    Atsuro Yokoyama
    International Journal of Implant Dentistry, 6
  • [45] Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures
    Suedam, Valdey
    Moretti Neto, Rafael Tobias
    Capello Sousa, Edson Antonio
    Rubo, Jose Henrique
    JOURNAL OF APPLIED ORAL SCIENCE, 2016, 24 (02) : 114 - 120
  • [46] Retrospective Analysis of Prosthetic Complications of Implant-Supported Fixed Partial Dentures After an Observation Period of 5 to 10 Years
    Vanlioglu, Burcin
    Ozkan, Yasar
    Kulak-Ozkan, Yasemin
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (05) : 1300 - 1304
  • [47] The impact of cantilevers on biological and technical success outcomes of implant-supported fixed partial dentures. A retrospective cohort study
    Kim, Paul
    Ivanovski, Saso
    Latcham, Neil
    Mattheos, Nikos
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (02) : 175 - 184
  • [48] Bone level change at implant-supported fixed partial dentures with and without cantilever extension after 5 years in function
    Wennström, J
    Zurdo, J
    Karlsson, S
    Ekestubbe, A
    Gröndahl, K
    Lindhe, J
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2004, 31 (12) : 1077 - 1083
  • [49] Maxillary changes under complete dentures opposing mandibular implant-supported fixed prostheses
    Gupta, S
    Lechner, SK
    Duckmanton, NA
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 1999, 12 (06) : 492 - 497
  • [50] Esthetic evaluation of single implant restorations, adjacent single implant restorations, and implant-supported fixed partial dentures: A 1-year prospective study
    Boon, L.
    De Mars, G.
    Favril, C.
    Duyck, J.
    Quirynen, M.
    Vandamme, K.
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2020, 22 (01) : 128 - 137