Influence of rigidity of retainers on dynamic behavior of implant-supported removable partial dentures

被引:6
|
作者
Nogawa, Toshifumi [1 ]
Saito, Masayasu [2 ]
Murashima, Naomichi [3 ]
Takayama, Yoshiyuki [4 ]
Yokoyama, Atsuro [2 ]
机构
[1] Hokkaido Univ Hosp, Prevent Dent, Sapporo, Hokkaido, Japan
[2] Hokkaido Univ, Div Oral Funct Sci, Oral Funct Prosthodont, Facil Dent Med, Sapporo, Hokkaido, Japan
[3] Hokkaido Univ, Grad Sch Dent Med, Div Oral Funct Sci, Oral Funct Prosthodont, Sapporo, Hokkaido, Japan
[4] Hokkaido Univ Hosp, Oral Rehabil, Sapporo, Hokkaido, Japan
关键词
Implant-supported partial dentures; Removable partial dentures; Direct retainers; Dynamic behavior; Rigidity of connection; FINITE-ELEMENT-ANALYSIS; MULTICENTER PROSPECTIVE EVALUATION; KENNEDY CLASS-I; DISTAL-EXTENSION; STRESS-DISTRIBUTION; ABUTMENT TOOTH; DENTAL PROSTHESIS; LOADING VARIABLES; DISPLACEMENT; PLACEMENT;
D O I
10.1186/s40729-020-00260-4
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background Implant-supported removable partial dentures (ISRPDs) are an effective treatment for partially edentulous patients. ISRPDs improve patients' satisfaction and oral function to a greater extent than RPDs by improving denture stability and enhancing support. However, the effect of a type of direct retainer on displacement of the abutment teeth and dentures in ISRPDs remains unclear. Therefore, we made a resin mandibular model of unilateral mandibular distal-extension partial edentulism for mechanical simulation and compared the dynamic behavior of the abutment teeth and the denture base among different tooth-borne retainers with various rigidities for RPDs and ISRPDs. Methods A resin mandibular model for mechanical simulation that had unilateral mandibular distal-extension edentulism and was missing the first molar, second molar, first premolar, and second premolar, and a denture fabricated from the patient's computed tomography images were used. Three types of direct retainers with different connecting rigidities were evaluated. The vertical displacement of the denture base and buccal and lingual sides and the mesial displacement of the abutment teeth were measured. Results Regardless of the rigidity of the direct retainers and loading positions, the displacement of the denture bases in the ISRPDs was significantly smaller than that in the RPDs (P < 0.001). There was no significant difference in vertical displacement of the denture bases among direct retainers with various connecting rigidities in the ISRPDs. Conversely, horizontal displacement of the abutment teeth in both the RPDs and ISRPDs tended to be larger with the cone crown telescope, which has high rigidity, than with the cast cingulum rest and wire clasp, which have much lower rigidities. Conclusion Our results suggested that cast cingulum rest and wire clasps as direct retainers are appropriate ISRPDs to minimize denture movement and suppress displacement of the remaining teeth in patients with unilateral mandibular distal-extension partial edentulism.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Influence of rigidity of retainers on dynamic behavior of implant-supported removable partial dentures
    Toshifumi Nogawa
    Masayasu Saito
    Naomichi Murashima
    Yoshiyuki Takayama
    Atsuro Yokoyama
    International Journal of Implant Dentistry, 6
  • [2] Cost-effectiveness of implant-supported mandibular removable partial dentures
    Jensen, Charlotte
    Ross, Jamila
    Feenstra, Talitha L.
    Raghoebar, Gerry M.
    Speksnijder, Caroline
    Meijer, Henny J. A.
    Cune, Marco S.
    CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (05) : 594 - 601
  • [3] The effect of implant-supported removable partial dentures on oral health quality of life
    Gates, W. Day, III
    Cooper, Lyndon F.
    Sanders, Anne E.
    Reside, Glenn J.
    De Kok, Ingeborg J.
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (02) : 207 - 213
  • [4] Removable dentures versus implant-supported prostheses in the elderly
    Bortolotti, L.
    DENTAL CADMOS, 2011, 79 (01) : 18 - 26
  • [5] Clinical Evaluation of Implant-Supported Removable Partial Dentures With a Stress-Breaking Attachment
    Suzuki, Yasunori
    Kono, Kentaro
    Shimpo, Hidemasa
    Sato, Yohei
    Ohkubo, Chikahiro
    IMPLANT DENTISTRY, 2017, 26 (04) : 516 - 523
  • [6] Pressure distribution of implant-supported removable partial dentures with stress-breaking attachments
    Kono, Kentaro
    Kurihara, Daisuke
    Suzuki, Yasunori
    Ohkubo, Chikahiro
    JOURNAL OF PROSTHODONTIC RESEARCH, 2014, 58 (02) : 115 - 120
  • [7] TELESCOPE RETAINERS FOR REMOVABLE PARTIAL DENTURES
    LANGER, A
    JOURNAL OF PROSTHETIC DENTISTRY, 1981, 45 (01): : 37 - 43
  • [8] Implant-supported mandibular removable partial dentures: Functional, clinical and radiographical parameters in relation to implant position
    Jensen, Charlotte
    Speksnijder, Caroline M.
    Raghoebar, Gerry M.
    Kerdijk, Wouter
    Meijer, Henny J. A.
    Cune, Marco S.
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2017, 19 (03) : 432 - 439
  • [9] Influence of mandibular distal extension implant-supported removable partial dentures on the force exerted on maxillary anterior teeth
    Arita, Shuhei
    Gonda, Tomoya
    Togawa, Hitomi
    Maeda, Yoshinobu
    Ikebe, Kazunori
    JOURNAL OF PROSTHODONTIC RESEARCH, 2021, 65 (04) : 541 - 545
  • [10] Implant-supported prostheses versus conventional permanent and removable dentures
    Koszuta, Agnieszka
    Szymanska, Jolanta
    CURRENT ISSUES IN PHARMACY AND MEDICAL SCIENCES, 2014, 27 (01) : 23 - 26