Direct Electrochemistry of Hemoglobin Immobilized on a Functionalized Multi-Walled Carbon Nanotubes and Gold Nanoparticles Nanocomplex-Modified Glassy Carbon Electrode

被引:47
|
作者
Hong, Jun [1 ]
Zhao, Ying-Xue [1 ]
Xiao, Bao-Lin [1 ]
Moosavi-Movahedi, Ali Akbar [2 ]
Ghourchian, Hedayatollah [2 ]
Sheibani, Nader [3 ]
机构
[1] Henan Univ, Sch Life Sci, Kaifeng 475000, Peoples R China
[2] Univ Tehran, Inst Biochem & Biophys, Tehran, Iran
[3] Univ Wisconsin, Dept Ophthalmol & Visual Sci, Madison, WI 53792 USA
基金
美国国家科学基金会;
关键词
hemoglobin; direct electrochemistry; functionalized multi-walled carbon nanotubes; gold nanoparticles; nanocomplex; TEMPERATURE IONIC LIQUID; HYDROGEN-PEROXIDE; HORSERADISH-PEROXIDASE; CYTOCHROME-C; PHOSPHATIDYLCHOLINE FILMS; 3RD-GENERATION BIOSENSOR; CONTAINING ENZYMES; REDOX PROTEINS; ELECTROCATALYSIS; MYOGLOBIN;
D O I
10.3390/s130708595
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Direct electron transfer of hemoglobin (Hb) was realized by immobilizing Hb on a carboxyl functionalized multi-walled carbon nanotubes (FMWCNTs) and gold nanoparticles (AuNPs) nanocomplex-modified glassy carbon electrode. The ultraviolet-visible absorption spectrometry (UV-Vis), transmission electron microscopy (TEM) and Fourier transform infrared (FTIR) methods were utilized for additional characterization of the AuNPs and FMWCNTs. The cyclic voltammogram of the modified electrode has a pair of well-defined quasi-reversible redox peaks with a formal potential of -0.270 +/- 0.002 V (vs. Ag/AgCl) at a scan rate of 0.05 V/s. The heterogeneous electron transfer constant (ks) was evaluated to be 4.0 +/- 0.2 s(-1). The average surface concentration of electro-active Hb on the surface of the modified glassy carbon electrode was calculated to be 6.8 +/- 0.3 x 10(-10) mol cm(-2). The cathodic peak current of the modified electrode increased linearly with increasing concentration of hydrogen peroxide (from 0.05 nM to 1 nM) with a detection limit of 0.05 +/- 0.01 nM. The apparent Michaelis-Menten constant (K-m(app)) was calculated to be 0.85 +/- 0.1 nM. Thus, the modified electrode could be applied as a third generation biosensor with high sensitivity, long-term stability and low detection limit.
引用
收藏
页码:8595 / 8611
页数:17
相关论文
共 50 条
  • [31] Application of multi-walled carbon nanotubes modified with boron oxide nanoparticles in electrochemistry
    Tsierkezos, Nikos G.
    Ritter, Uwe
    Thaha, Yudi. Nugraha
    Downing, Clive
    [J]. IONICS, 2015, 21 (11) : 3087 - 3095
  • [32] Simultaneous electrochemical determination of hydroquinone, catechol and resorcinol at Nafion/multi-walled carbon nanotubes/carbon dots/multi-walled carbon nanotubes modified glassy carbon electrode
    Wei, Chan
    Huang, Qitong
    Hu, Shirong
    Zhang, Hanqiang
    Zhang, Wuxiang
    Wang, Zhaoming
    Zhu, Menglin
    Dai, Pingwang
    Huang, Lizhang
    [J]. ELECTROCHIMICA ACTA, 2014, 149 : 237 - 244
  • [33] Direct electrochemistry and electrocatalysis of catalase immobilized on multi-wall carbon nanotubes modified glassy carbon electrode and its application
    Zhou, Hui
    Lu, Tian-Hong
    Shi, Hong-Xia
    Dai, Zhi-Hui
    Huang, Xiao-Hua
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2008, 612 (02) : 173 - 178
  • [34] Cathodic electrogenerated chemiluminescence of luminol on glassy carbon electrode modified with cobalt nanoparticles decorated multi-walled carbon nanotubes
    Haghighi, Behzad
    Tavakoli, Azam
    Bozorgzadeh, Somayyeh
    [J]. ELECTROCHIMICA ACTA, 2015, 154 : 259 - 265
  • [35] Direct Electrochemistry of Hemoglobin Immobilized on Glassy Carbon Electrode Modified with Anodic Alumina Oxide Films
    Wu Wuai
    Guo Mandong
    Yin Zhifen
    Wei Jingrui
    Li Jingfang
    Li Jun
    Zhang Yu
    [J]. ACTA CHIMICA SINICA, 2009, 67 (08) : 781 - 785
  • [36] Direct electrochemistry of immobilized hemoglobin and sensing of bromate at a glassy carbon electrode modified with graphene and β-cyclodextrin
    Selvakumar Palanisamy
    Yi-Ting Wang
    Shen-Ming Chen
    Balamurugan Thirumalraj
    Bih-Show Lou
    [J]. Microchimica Acta, 2016, 183 : 1953 - 1961
  • [37] Direct electrochemistry of immobilized hemoglobin and sensing of bromate at a glassy carbon electrode modified with graphene and β-cyclodextrin
    Palanisamy, Selvakumar
    Wang, Yi-Ting
    Chen, Shen-Ming
    Thirumalraj, Balamurugan
    Lou, Bih-Show
    [J]. MICROCHIMICA ACTA, 2016, 183 (06) : 1953 - 1961
  • [38] Direct Electrochemistry and Electrocatalysis of the Hemoglobin Immobilized on Diazonium-Functionalized Aligned Carbon Nanotubes Electrode
    Yang, Jing
    Xu, Ying
    Zhang, Renyi
    Wang, Yanzhi
    He, Pingang
    Fang, Yuzhi
    [J]. ELECTROANALYSIS, 2009, 21 (15) : 1672 - 1677
  • [39] Direct electrochemistry of hemoglobin immobilized on the water-soluble phosphonate functionalized multi-walled carbon nanotubes and its application to nitric oxide biosensing
    Li, Pan
    Ding, Yu
    Lu, Zhaoyang
    Li, Ying
    Zhu, Xiaoshu
    Zhou, Yiming
    Tang, Yawen
    Chen, Yu
    Cai, Chenxin
    Lu, Tianhong
    [J]. TALANTA, 2013, 115 : 228 - 234
  • [40] Application of a glassy carbon electrode modified with functionalized multi-walled carbon nanotubes as a sensor device for simultaneous determination of acetaminophen and tyramine
    Raoof, Jahan Bakhsh
    Ojani, Reza
    Baghayeri, Mehdi
    Amiri-Aref, Mohaddeseh
    [J]. ANALYTICAL METHODS, 2012, 4 (06) : 1579 - 1587