Attenuation-based Automatic Tube Voltage Selection and Tube Current Modulation for Dose Reduction at Contrast-enhanced Liver CT

被引:78
|
作者
Lee, Kyung Hee [1 ]
Lee, Jeong Min [1 ]
Moon, Sung Kyoung [1 ]
Baek, Jee Hyun [1 ]
Park, Ji Hoon [1 ]
Flohr, Thomas G. [2 ]
Kim, Kyung Won [1 ]
Kim, Soo Jin [1 ]
Han, Joon Koo [1 ]
Choi, Byung Ihn [1 ]
机构
[1] Seoul Natl Univ, Coll Med, Inst Radiat Med, Dept Radiol,Div Abdominal Imaging, Seoul 110744, South Korea
[2] Siemens Med Solut, Forchheim, Germany
关键词
STATISTICAL ITERATIVE RECONSTRUCTION; INITIAL CLINICAL-EXPERIENCE; IMPROVED IMAGE QUALITY; MULTIDETECTOR ROW CT; ABDOMINAL CT; COMPUTED-TOMOGRAPHY; RADIATION-EXPOSURE; PATIENT SIZE; OPTIMIZATION; FEASIBILITY;
D O I
10.1148/radiol.12112434
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To retrospectively determine whether the combined use of automatic tube voltage selection (ATVS) and automatic tube current modulation (ATCM) can effectively reduce radiation dose at contrast material-enhanced liver computed tomography (CT) while maintaining acceptable image quality compared with the use of ATCM alone. Materials and Methods: This study was approved by an institutional review board, and informed consent was waived. Three hundred fourteen consecutive patients suspected of having liver disease were divided into three groups. In two groups, both ATVS and ATCM were used (group A1, n = 97; group A2, n = 101) but with different contrast gain settings; in one group, only ATCM with a fixed tube potential of 120 kV (group B, n = 116) was used. Weighted volume CT dose index and dose-length product, contrast-to-noise ratios (CNRs), and mean image noise were assessed. Qualitative analysis was performed by two board-certified radiologists and one radiology resident. Statistical analysis was performed by using the one-way analysis of variance test, two-tailed paired t test, Kruskal-Wallis test, and noninferiority test. Results: In groups A1 and A2, a significant dose reduction was obtained compared with that in group B (P < .0001). The mean dose reduction was 20% in group A1 and 31% in group A2. Furthermore, CNRs were significantly higher in groups A1 and A2 than in group B (P < .0001). Despite the higher image noise in groups A1 and A2, the overall image quality was acceptable. Conclusion: Compared with the use of ATCM alone, the combined use of ATVS and ATCM allowed reduction of radiation exposure while maintaining good image quality at contrast-enhanced liver CT.
引用
收藏
页码:437 / 447
页数:11
相关论文
共 50 条
  • [41] Dose reduction in CT examinations of children by anatomically adapted tube current modulation
    Greess, H
    Noemayr, A
    Wolf, H
    Janka, R
    Kalender, WA
    Bautz, WA
    RADIOLOGY, 1999, 213P : 294 - 294
  • [42] Dose reduction in body CT examinations by anatomically adapted tube current modulation
    Bautz, WA
    Heim, I
    Wolf, H
    Kalender, WA
    RADIOLOGY, 1997, 205 : 1399 - 1399
  • [43] Effects of tube potential selection together with computed tomography automatic tube current modulation on CT imaging performance
    Sookpeng, S.
    Martin, C. J.
    Krisanachinda, A.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2021, 41 (04) : 809 - 831
  • [44] Thyroid Shields versus z-Axis Automatic Tube Current Modulation for Dose Reduction at Neck CT
    Leswick, David A.
    Hunt, Megan M.
    Webster, Steven T.
    Fladeland, Derek A.
    RADIOLOGY, 2008, 249 (02) : 572 - 580
  • [45] Techniques and applications of automatic tube current modulation for CT
    Kalra, MK
    Maher, MM
    Toth, TL
    Schmidt, B
    Westerman, BL
    Morgan, HT
    Saini, S
    RADIOLOGY, 2004, 233 (03) : 649 - 657
  • [46] Synergistic Radiation Dose Reduction by Combining Automatic Tube Voltage Selection and Iterative Reconstruction
    Wortman, Jeremy R.
    Adduci, Alexander J.
    Sodickson, Aaron D.
    JOURNAL OF THORACIC IMAGING, 2016, 31 (02) : 111 - 118
  • [47] Estimated Patient Dose Indexes in Adult and Pediatric MDCT: Comparison of Automatic Tube Voltage Selection With Fixed Tube Current, Fixed Tube Voltage, and Weight-Based Protocols
    Baker, Mark E.
    Karim, Wadih
    Bullen, Jennifer A.
    Primak, Andrew N.
    Dong, Frank F.
    Herts, Brian R.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (03) : 592 - 598
  • [48] Individual modulation of the tube current-seconds to achieve similar levels of image noise in contrast-enhanced abdominal CT
    Irie, T
    Inoue, H
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (05) : 1514 - 1518
  • [49] Real-Time Dose Measurements of Automatic Tube Current Modulation in Multislice CT
    Tsai, H. Y.
    Chang, Y. C.
    Tyan, Y. S.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [50] Combined Use of Automatic Tube Potential Selection with Tube Current Modulation and Iterative Reconstruction Technique in Coronary CT Angiography
    Suh, Young Joo
    Kim, Young Jin
    Hong, Sae Rom
    Hong, Yoo Jin
    Lee, Hye-Jeong
    Hur, Jin
    Choi, Byoung Wook
    RADIOLOGY, 2013, 269 (03) : 722 - 729