Characterization of the electrical response of the HPGe segmented detectors is one of the current goals for the Nuclear Physics community in order to perform gamma-ray tracking or even imaging with these detectors. For this purpose, scanning devices have to be developed to achieve the signal-position association. with the highest precision. In our laboratory, a new scanmng system, SALSA, acronym of SAlamanca Lyso-based Scanning Array, consisting on a high spatial resolution gamma camera is under development. In this work the SALSA system is presented and the results for the characterization of the gamma camera are shown.
引用
收藏
页码:1506 / 1509
页数:4
相关论文
共 50 条
  • [21] Quantification of STEM Images in High Resolution SEM for Segmented and Pixelated Detectors
    Konvalina, Ivo
    Patak, Ales
    Zouhar, Martin
    Muellerova, Ilona
    Fort, Tomas
    Uncovsky, Marek
    Materna Mikmekova, Eliska
    NANOMATERIALS, 2022, 12 (01)
  • [22] Response of the composite cluster HPGe detectors of the EUROBALL array to high energy γ-rays
    Million, B
    Bracco, A
    Camera, F
    Brambilla, S
    Leoni, S
    Wieland, O
    Kmiecik, M
    Maj, A
    Herskind, B
    Gadea, A
    ACTA PHYSICA POLONICA B, 2001, 32 (03): : 847 - 853
  • [23] HIGH SPATIAL-RESOLUTION PARTICLE PHYSICS DETECTORS
    EISLER, FR
    NUCLEAR INSTRUMENTS & METHODS, 1979, 163 (01): : 105 - 111
  • [24] HIGH SPATIAL-RESOLUTION PARTICLE PHYSICS DETECTORS
    EISLER, FR
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1979, 24 (01): : 43 - 44
  • [25] A New Compton Camera Imaging Model to Mitigate the Finite Spatial Resolution of Detectors and New Camera Designs for Implementation
    Smith, Bruce
    TECHNOLOGIES, 2015, 3 (04): : 219 - 237
  • [26] Energy and DOI Calibrations for High Spatial Resolution CZT Detectors
    Carrascal, J.
    Castilla, J.
    Oller, J. C.
    Vela, O.
    Romero, L.
    Rato, P.
    Perez, J. M.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2014, 61 (01) : 518 - 527
  • [27] Electrical subsystem of the High Resolution Stereo Camera for Mars express
    Schönfeldt, U
    Krieger, J
    Behnke, T
    DASIA 2000: DATA SYSTEMS IN AEROSPACE, PROCEEDINGS, 2000, 457 : 77 - 82
  • [28] High spatial resolution neutron sensing microchannel plate detectors
    Siegmund, Oswald H.
    Vallerga, John V.
    Tremsin, Anton S.
    Mcphate, Jason
    Feller, Bruce
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 576 (01): : 178 - 182
  • [29] Recent developments on high spatial resolution CdZnTe pixel detectors
    Perez, Jose M.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 5279 - 5284
  • [30] High spatial resolution detectors and particle lifetime measurements at LEP
    Coyle, P
    Schneider, O
    COMPTES RENDUS PHYSIQUE, 2002, 3 (09) : 1143 - 1154