Double Filtration During Carotid Artery Stenting Using a Novel Post-Dilation Balloon With Integrated Embolic Protection

被引:11
|
作者
Langhoff, Ralf [1 ]
Schofer, Joachim [2 ]
Scheinert, Dierk [3 ]
Schmidt, Andrej [3 ]
Sedgewick, Gerald [4 ]
Saylors, Elizabeth [5 ]
Sachar, Ravish [6 ]
Sievert, Horst [7 ,8 ]
Zeller, Thomas [9 ]
机构
[1] Sankt Gertrauden Krankenhaus GmbH, Dept Angiol, Berlin, Germany
[2] Med Care Ctr Prof Mathey, Dept Cardiol, Hamburg, Germany
[3] Univ Hosp Leipzig, Clin Angiol, Leipzig, Germany
[4] Imaging & Anal LLC, St Paul, MN USA
[5] Contego Med LLC, Raleigh, NC USA
[6] UNC REX Healthcare, Heart & Vasc Serv, Raleigh, NC USA
[7] CardioVasc Ctr Frankfurt, Frankfurt, Germany
[8] Anglia Ruskin Univ, Chelmsford, Essex, England
[9] Univ Herzzentrum Freiburg Bad Krozingen, Dept Angiol, Bad Krozingen, Germany
关键词
carotid artery stenting; cerebral embolic protection; double filtration; periprocedural stroke; SURGICAL-RISK PATIENTS; FILTER PROTECTION; DISTAL PROTECTION; ENDARTERECTOMY; TRIAL; METAANALYSIS; ANGIOPLASTY; OCCLUSION; REGISTRY; MICROEMBOLIZATION;
D O I
10.1016/j.jcin.2018.11.039
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study evaluated the safety and performance of the Paladin System, a novel angioplasty balloon with an integrated embolic protection filter designed to increase embolic protection during post-dilation. BACKGROUND The risk of major adverse events during carotid artery stenting (CAS) is equivalent to carotid endarterectomy. However, the risk of minor stroke remains higher with CAS. Much of this risk occurs during post-stent dilation. METHODS A total of 106 patients were enrolled in 5 centers in Germany. The study's primary endpoint was all-cause death, myocardial infarction, and stroke at 30 days post-procedure. Pre- and post-procedural diffusion-weighted magnetic resonance imaging evaluated new ischemic lesions in 30 subjects. Filter histomorphometric analysis was performed in 23 patients. Retrospective analyses compared outcome rates to historical controls. RESULTS Device and procedural success rates were 100%. The combined major adverse event rate (death, myocardial infarction, and stroke) at discharge and at 30 days was 0% and 1.0%, respectively. The single adverse event was a stroke, which occurred at day 12 and was believed unrelated to the device or procedure. New ischemic lesions were found in 11 (36.7%) patients in the diffusion-weighted magnetic resonance imaging subset. New ipsilateral lesions were seen in 9 (30.0%) patients. Mean lesion volume per patient was 0.010 cm(3). Debris was present in all filters, and approximately 90% of captured particles were <100 mm. CONCLUSIONS Use of the Paladin System for post-stent dilation during CAS appears safe, and it may effectively decrease the number of embolic particles reaching the brain, which may help reduce the risk of procedure-related stroke. (A Multi-Center Study to Evaluate Acute Safety and Clinical Performance of Paladin (R) Carotid Post-Dilation Balloon System With Integrated Embolic Protection; NCT02501148) (J Am Coll Cardiol Intv 2019;12:395-403) (c) 2019 by the American College of Cardiology Foundation.
引用
收藏
页码:395 / 403
页数:9
相关论文
共 50 条
  • [41] Distal embolic protection use during transfemoral carotid artery stenting is associated with improved in-hospital outcomes
    Wang, Sophie X.
    Marcaccio, Christina L.
    Patel, Priya B.
    Giles, Kristina A.
    Soden, Peter A.
    Schermerhorn, Marc L.
    Liang, Patric
    JOURNAL OF VASCULAR SURGERY, 2023, 77 (06)
  • [42] Slow-flow phenomenon during carotid artery stenting with embolic protection devices: Predictors and clinical outcome
    Casserly, IP
    Abou-Chebl, A
    Fathi, RB
    Lee, DS
    Saw, J
    Exaire, JE
    Bajzer, CT
    Kapadia, SR
    Bhatt, DL
    Yadav, J
    CIRCULATION, 2004, 110 (17) : 613 - 613
  • [43] Distal embolic protection devices, high intensity transient signals and neurological outcomes during carotid artery stenting
    Gruberg, L
    Nair, P
    Kerner, A
    Petchersky, S
    Kouperberg, E
    Beyar, R
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 31B - 31B
  • [44] Carotid artery stenting with double cerebral embolic protection in asymptomatic patients - a diffusion-weighted MRI controlled study
    Vuruskan, Ertan
    Saracoglu, Erhan
    Ergun, Ugur
    Poyraz, Fatih
    Duzen, Irfan Veysel
    VASA-EUROPEAN JOURNAL OF VASCULAR MEDICINE, 2017, 46 (01) : 29 - 35
  • [45] Predictors of Clamping Intolerance during Carotid Artery Stenting using Proximal Protection
    Stabile, Eugenio
    Petroni, Giampaolo
    Giovanni, Sorropago
    Della Pietra, Giovanni
    Tesorio, Tullio
    Ausania, Angelo
    Miranda, Marianna
    Fotanelli, Arturo
    Biamino, Giancarlo
    Rubino, Paolo
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (6A): : 22D - 22D
  • [46] Tandem balloon protection during emergency carotid artery stenting of a stenotic ICA lesion with intraluminal thrombus
    Imai, Keisuke
    Makino, Masahiro
    Niwa, Furnitoshi
    Takegarni, Tetsuro
    Koike, Hironori
    Azuma, Yurniko
    Oshima, Fumiko
    Oda, Kenichiro
    Kakita, Kiyohito
    JOURNAL OF ENDOVASCULAR THERAPY, 2007, 14 (02) : 214 - 218
  • [47] Comparison of balloon occlusion-based vs filter-based embolic protection devices in patients undergoing carotid artery stenting
    Arjomand, H
    Bruno, N
    Gorodin, P
    Espinoza, A
    Bowers, B
    Dairywala, I
    Alani, F
    Thomas, C
    Yanoschak, J
    Koenisberg, R
    Goldberg, S
    McCormick, D
    AMERICAN JOURNAL OF CARDIOLOGY, 2004, 94 (6A): : 61E - 61E
  • [48] Predictors Of Carotid Clamping Intolerance During Carotid Artery Stenting With Proximal Embolic Protection Device. Results From An Italian Registry
    Giugliano, Giuseppe
    Stabile, Eugenio
    Sannino, Anna
    Brevetti, Linda
    Pucciarelli, Armando
    Popusoi, Grigore
    Tesorio, Tullio
    Cioppa, Angelo
    Cota, Linda
    Salemme, Luigi
    Schiano, Vittorio
    Sorropago, Antonio
    Esposito, Giovanni
    Rubino, Paolo
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (18) : B154 - B154
  • [49] Carotid artery stenting with embolic protection is associated with similar outcomes in post-carotid endarterectomy restenotic lesions versus de novo lesions
    Lee, DS
    Casserly, IP
    Yen, MH
    Chen, MS
    Saw, J
    Exaire, JE
    Fathi, RB
    Kapadia, SR
    Bajzer, CT
    Yadav, JS
    CIRCULATION, 2004, 110 (17) : 613 - 613
  • [50] Carotid Artery Back Pressure and Cerebral Intolerance During the Occlusion in Carotid Stenting with the Mo.Ma Proximal Embolic Protection Device
    Bilge, Mehmet
    Alemdar, Recai
    Ali, Sina
    Yasar, Ayse Saatci
    Kirbas, Ozgur
    Akdi, Ahmet
    Kurmus, Ozge
    Aslan, Turgay
    Koseoglu, Cemal
    Duran, Bilge Karaduman
    Erdogan, Mehmet
    Sivri, Serkan
    Suygun, Halan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (18) : C77 - C77