Double Filtration During Carotid Artery Stenting Using a Novel Post-Dilation Balloon With Integrated Embolic Protection

被引:11
|
作者
Langhoff, Ralf [1 ]
Schofer, Joachim [2 ]
Scheinert, Dierk [3 ]
Schmidt, Andrej [3 ]
Sedgewick, Gerald [4 ]
Saylors, Elizabeth [5 ]
Sachar, Ravish [6 ]
Sievert, Horst [7 ,8 ]
Zeller, Thomas [9 ]
机构
[1] Sankt Gertrauden Krankenhaus GmbH, Dept Angiol, Berlin, Germany
[2] Med Care Ctr Prof Mathey, Dept Cardiol, Hamburg, Germany
[3] Univ Hosp Leipzig, Clin Angiol, Leipzig, Germany
[4] Imaging & Anal LLC, St Paul, MN USA
[5] Contego Med LLC, Raleigh, NC USA
[6] UNC REX Healthcare, Heart & Vasc Serv, Raleigh, NC USA
[7] CardioVasc Ctr Frankfurt, Frankfurt, Germany
[8] Anglia Ruskin Univ, Chelmsford, Essex, England
[9] Univ Herzzentrum Freiburg Bad Krozingen, Dept Angiol, Bad Krozingen, Germany
关键词
carotid artery stenting; cerebral embolic protection; double filtration; periprocedural stroke; SURGICAL-RISK PATIENTS; FILTER PROTECTION; DISTAL PROTECTION; ENDARTERECTOMY; TRIAL; METAANALYSIS; ANGIOPLASTY; OCCLUSION; REGISTRY; MICROEMBOLIZATION;
D O I
10.1016/j.jcin.2018.11.039
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study evaluated the safety and performance of the Paladin System, a novel angioplasty balloon with an integrated embolic protection filter designed to increase embolic protection during post-dilation. BACKGROUND The risk of major adverse events during carotid artery stenting (CAS) is equivalent to carotid endarterectomy. However, the risk of minor stroke remains higher with CAS. Much of this risk occurs during post-stent dilation. METHODS A total of 106 patients were enrolled in 5 centers in Germany. The study's primary endpoint was all-cause death, myocardial infarction, and stroke at 30 days post-procedure. Pre- and post-procedural diffusion-weighted magnetic resonance imaging evaluated new ischemic lesions in 30 subjects. Filter histomorphometric analysis was performed in 23 patients. Retrospective analyses compared outcome rates to historical controls. RESULTS Device and procedural success rates were 100%. The combined major adverse event rate (death, myocardial infarction, and stroke) at discharge and at 30 days was 0% and 1.0%, respectively. The single adverse event was a stroke, which occurred at day 12 and was believed unrelated to the device or procedure. New ischemic lesions were found in 11 (36.7%) patients in the diffusion-weighted magnetic resonance imaging subset. New ipsilateral lesions were seen in 9 (30.0%) patients. Mean lesion volume per patient was 0.010 cm(3). Debris was present in all filters, and approximately 90% of captured particles were <100 mm. CONCLUSIONS Use of the Paladin System for post-stent dilation during CAS appears safe, and it may effectively decrease the number of embolic particles reaching the brain, which may help reduce the risk of procedure-related stroke. (A Multi-Center Study to Evaluate Acute Safety and Clinical Performance of Paladin (R) Carotid Post-Dilation Balloon System With Integrated Embolic Protection; NCT02501148) (J Am Coll Cardiol Intv 2019;12:395-403) (c) 2019 by the American College of Cardiology Foundation.
引用
收藏
页码:395 / 403
页数:9
相关论文
共 50 条
  • [21] Feasibility of Carotid Artery Stenting with Double Cerebral Embolic Protection in High-Risk Patients
    Varbella, Ferdinando
    Gagnor, Andrea
    Rolfo, Cristina
    Cerrato, Enrico
    Bollati, Mario
    Pron, Paolo Giay
    Hartwig, Massimo
    Restrepo, Sara Palacio
    Reggiani, Monica
    Amaru, Salvatore
    di Cortemiglia, Emilio Luda
    Tomassini, Francesco
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2016, 87 (03) : 432 - 437
  • [22] Simulation study of distal balloon protection systems during carotid artery stenting
    Kuroiwa, T
    Sakai, N
    Sakaguchi, M
    Adachi, H
    Imamura, H
    Sakai, C
    Morizane, A
    Ishihara, H
    Yano, T
    Nakao, S
    Kikuchi, H
    INTERVENTIONAL NEURORADIOLOGY, 2004, 10 : 79 - 84
  • [23] Usefulness of dual protection combined with blood aspiration for distal embolic protection during carotid artery stenting
    Shigeyuki Sakamoto
    Yoshihiro Kiura
    Takahito Okazaki
    Katsuhiro Shinagawa
    Nobuhiko Ichinose
    Masaaki Shibukawa
    Yoji Orita
    Koji Shimonaga
    Yosuke Kajihara
    Kaoru Kurisu
    Acta Neurochirurgica, 2015, 157 : 371 - 377
  • [24] Usefulness of dual protection combined with blood aspiration for distal embolic protection during carotid artery stenting
    Sakamoto, Shigeyuki
    Kiura, Yoshihiro
    Okazaki, Takahito
    Shinagawa, Katsuhiro
    Ichinose, Nobuhiko
    Shibukawa, Masaaki
    Orita, Yoji
    Shimonaga, Koji
    Kajihara, Yosuke
    Kurisu, Kaoru
    ACTA NEUROCHIRURGICA, 2015, 157 (03) : 371 - 377
  • [25] First clinical experience with the GARDEX EPD: a novel embolic protection device for carotid artery stenting
    Werner, Martin
    Scheinert, Dierk
    Borghesi, Raffaello
    Cremonesi, Alberto
    Rosenschein, Uri
    Scheinert, Susanne
    Braeunlich, Sven
    Bausback, Yvonne
    Ulrich, Matthias
    Schmidt, Andrej
    EUROINTERVENTION, 2013, 8 (09) : 1026 - 1032
  • [26] Comparison of Anti- Embolic Protection with Proximal Balloon Occlusion and Filter Devices During Carotid Artery Stenting: Clinical and Procedural Outcomes
    Tatli, Ersan
    Buturak, Ali
    Dogan, Emir
    Alkan, Mustafa
    Sayin, Murat
    Yilmaztepe, Mustafa
    Atakay, Selcuk
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (18) : C76 - C76
  • [27] Comparison of anti-embolic protection with proximal balloon occlusion and filter devices during carotid artery stenting: clinical and procedural outcomes
    Tatli, Ersan
    Buturak, Ali
    Grunduz, Yasemin
    Dogan, Emir
    Alkan, Mustafa
    Sayin, Murat
    Yilmaztepe, Mustafa
    Atakay, Selcuk
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2013, 9 (03): : 221 - 227
  • [28] Differences in the rate of cerebral ischemia during carotid artery stenting by type of embolic protection device
    Tuebler, T.
    Pascotto, A.
    Schofer, J.
    EUROPEAN HEART JOURNAL, 2009, 30 : 982 - 982
  • [29] Predictors of acute clinical events during carotid artery stenting in the era of embolic protection devices
    Zahn, R
    Mark, B
    Zeymer, U
    Niedermaier, N
    Von Leitner, E
    Ischinger, T
    Kasper, W
    Senges, J
    EUROPEAN HEART JOURNAL, 2004, 25 : 641 - 641
  • [30] Entrapment of an embolic protection device within stent during carotid artery stenting: a case report
    Hyun Jin Kim
    Sanghyeon Kim
    Myongjin Kang
    The Egyptian Journal of Neurology, Psychiatry and Neurosurgery, 59