Research on Direct Calibration of Electromagnetic Flowmeter in Partially Filled Pipes

被引:1
|
作者
Yin, Shiyi [1 ]
Li, Bin [1 ]
机构
[1] Shanghai Univ, Sch Mechatron Engn & Automat, Shanghai 200072, Peoples R China
关键词
Direct Calibration; Electromagnetic Flowmeter; Partially Filled Pipe; Piecewise Interpolation;
D O I
10.4028/www.scientific.net/AMR.712-715.1904
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The methodology of the direct calibration for the electromagnetic flowmeter in partially filled pipes is presented in this paper. Based on the principle of the electromagnetic flowmeter, two main respects, including the flow liquid level and the weight function in partially filled pipes are introduced briefly, and the calibration technologies of the sensor, which consist of the device arrangements, the accurate measurement of the liquid level and the calibration of the flow discharge, are emphasized on, with the methodology based on the piecewise interpolation employed. The experimental results demonstrate that the methodology of the direct calibration is simple and effective for the real flow calibration of the electromagnetic flowmeter in partially filled pipes, with the stable measurement and the accuracy requirement satisfied.
引用
收藏
页码:1904 / 1909
页数:6
相关论文
共 50 条
  • [21] CALIBRATION CHARACTERISTICS OF PULSED-FIELD ELECTROMAGNETIC FLOWMETER
    BECK, R
    MORRIS, JA
    ASSALI, NS
    AMERICAN JOURNAL OF MEDICAL ELECTRONICS, 1965, 4 (02): : 87 - &
  • [22] Research of Electromagnetic Flowmeter with Grounding Electrode
    Gao, Song
    Li, Bin
    Yin, Shi Yi
    ADVANCES IN MANUFACTURING SCIENCE AND ENGINEERING, PTS 1-4, 2013, 712-715 : 1856 - 1862
  • [24] Dry calibration procedure of electromagnetic flowmeter for open channels
    Michalski, A
    IMTC/99: PROCEEDINGS OF THE 16TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS. 1-3, 1999, : 1011 - 1016
  • [25] Partially filled pipes: experiments in laminar and turbulent flow
    Ng, Henry C. -H.
    Cregan, Hope L. F.
    Dodds, Jonathan M.
    Poole, Robert J.
    Dennis, David J. C.
    JOURNAL OF FLUID MECHANICS, 2018, 848 : 467 - 507
  • [26] VELOCITY AND DEPTH OF FLOW CALCULATIONS IN PARTIALLY FILLED PIPES
    SAATCI, A
    JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 1990, 116 (06): : 1202 - 1208
  • [27] Calibration and Optimization of an Insertion Electromagnetic Flowmeter With the Aid of Numerical Analysis
    Ma, Haibo
    Ma, Shilei
    Moss, Robert
    Fisher, Mark
    Silaen, Armin K.
    Zhou, Chenn Q.
    JOURNAL OF COMPUTING AND INFORMATION SCIENCE IN ENGINEERING, 2022, 22 (02)
  • [28] SEMI-AUTOMATIC CALIBRATION TECHNIQUE FOR ELECTROMAGNETIC FLOWMETER PROBES
    WOLFSON, SK
    ICOZ, MV
    SURUR, F
    PRITCHARD, M
    MEDICAL RESEARCH ENGINEERING, 1968, 7 (04) : 37 - +
  • [29] IN VIVO CALIBRATION OF ELECTROMAGNETIC FLOWMETER PROBES ON PULMONARY ARTERY AND AORTA
    WEBER, KC
    ENGLE, JC
    LYONS, GW
    MADSEN, AJ
    FOX, IJ
    JOURNAL OF APPLIED PHYSIOLOGY, 1968, 25 (04) : 455 - &
  • [30] Effect of secondary currents on the flow and turbulence in partially filled pipes
    Liu, Yan
    Stoesser, T.
    Fang, H.
    JOURNAL OF FLUID MECHANICS, 2022, 938