Influence of Distal Stenosis on Blood Flow Through Coronary Serial Stenoses: A Numerical Study

被引:6
|
作者
Liu, Biyue [1 ]
Tang, Dalin [2 ,3 ]
机构
[1] Monmouth Univ, Dept Math, West Long Branch, NJ 07764 USA
[2] Southeast Univ, Sch Biol Sci & Med Engn, Nanjing 201196, Jiangsu, Peoples R China
[3] Worcester Polytech Inst, Dept Math Sci, Worcester, MA 01609 USA
关键词
Right coronary artery; serial stenoses; pressure drop; wall shear stress; flow disturbance; SHEAR-STRESS; ARTERY; MULTIPLE; VALIDATION; SIMULATION; CURVATURE; TURBULENT; DYNAMICS; SINGLE;
D O I
10.1142/S0219876218420033
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Computer simulations of the blood flow through right coronary arteries with two stenoses in the same arterial segment are carried out to investigate the interactions of serial stenoses, especially the effect of the distal stenosis. Various mathematical models are developed by varying the location of the distal stenosis. The numerical results show that the variation of the distal stenosis has significant impact on coronary hemodynamics, such as the pressure drop, flow shifting, wall shear stress and flow separation. Our simulations demonstrate that the distal stenosis has insignificant effect on the disturbed flow pattern in the regions of upstream and across the proximal stenosis. In a curved artery segment with two moderate stenoses of the same size, the distal stenosis causes a larger pressure drop and a more disturbed flow field in the poststenotic region than the proximal stenosis does. A distal stenosis located at a further downstream position causes a larger pressure drop and a stronger reverse flow.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Blood flow through an axisymmetric stenosis
    Pontrelli, G
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2001, 215 (H1) : 1 - 10
  • [42] Comparison of numerical implementations for modelling flow through arterial stenoses
    Lyras, Konstantinos G.
    Lee, Jack
    International Journal of Mechanical Sciences, 2021, 211
  • [43] Blood flow through an axisymmetric stenosis
    Pontrelli, G.
    Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2015, 215 (01) : 1 - 10
  • [44] Coronary flow velocity-pressure relationship distal to the stenosis
    Tanaka, N
    Takazawa, K
    Fujita, M
    Saiki, T
    Matsuoka, O
    Aikawa, M
    Tamura, S
    Ibuklyama, C
    CIRCULATION, 1998, 98 (17) : 162 - 162
  • [45] Coronary flow-pressure relationship distal to epicardial stenosis
    Tanaka, N
    Takazawa, K
    Takeda, K
    Aikawa, M
    Shindo, N
    Amaya, K
    Kobori, Y
    Yamashina, A
    CIRCULATION JOURNAL, 2003, 67 (06) : 525 - 529
  • [46] Numerical simulation of unsteady generalized Newtonian blood flow through differently shaped distensible arterial stenoses
    Department of Mathematics, Visva-Bharati University, PO, Santiniketan, 731235 West Bengal, India
    不详
    J. Med. Eng. Technol., 2008, 5 (385-399):
  • [47] Coronary blood flow and severe aortic stenosis
    Carberry, Jaclyn
    Ang, Daniel
    Berry, Colin
    HEART, 2023, 109 (01) : 6 - 7
  • [48] Unsteady simulation of distal blood flow in an end-to-side anastomosed coronary bypass graft with stenosis
    Najarian, Siamak
    Dargahi, Javad
    Firouzi, Faramarz
    Afsari, Jamshid
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2006, 16 (05) : 337 - 347
  • [49] Numerical Analysis of the Blood Flow in an Artery with Stenosis
    Tomaszewski, Michal
    Malachowski, Jerzy
    BIOMECHANICS IN MEDICINE AND BIOLOGY, 2019, 831 : 68 - 77
  • [50] EFFECT OF STENOSIS LOCATION ON THE FLOW DISTRIBUTION IN CORONARY BRANCHES: EXPERIMENTAL AND NUMERICAL STUDY
    Abuouf, Yasser
    Albadawi, Muhamed
    Ahmed, Mahmoud
    PROCEEDINGS OF ASME 2021 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION (IMECE2021), VOL 5, 2021,