Influence of Distal Stenosis on Blood Flow Through Coronary Serial Stenoses: A Numerical Study

被引:6
|
作者
Liu, Biyue [1 ]
Tang, Dalin [2 ,3 ]
机构
[1] Monmouth Univ, Dept Math, West Long Branch, NJ 07764 USA
[2] Southeast Univ, Sch Biol Sci & Med Engn, Nanjing 201196, Jiangsu, Peoples R China
[3] Worcester Polytech Inst, Dept Math Sci, Worcester, MA 01609 USA
关键词
Right coronary artery; serial stenoses; pressure drop; wall shear stress; flow disturbance; SHEAR-STRESS; ARTERY; MULTIPLE; VALIDATION; SIMULATION; CURVATURE; TURBULENT; DYNAMICS; SINGLE;
D O I
10.1142/S0219876218420033
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Computer simulations of the blood flow through right coronary arteries with two stenoses in the same arterial segment are carried out to investigate the interactions of serial stenoses, especially the effect of the distal stenosis. Various mathematical models are developed by varying the location of the distal stenosis. The numerical results show that the variation of the distal stenosis has significant impact on coronary hemodynamics, such as the pressure drop, flow shifting, wall shear stress and flow separation. Our simulations demonstrate that the distal stenosis has insignificant effect on the disturbed flow pattern in the regions of upstream and across the proximal stenosis. In a curved artery segment with two moderate stenoses of the same size, the distal stenosis causes a larger pressure drop and a more disturbed flow field in the poststenotic region than the proximal stenosis does. A distal stenosis located at a further downstream position causes a larger pressure drop and a stronger reverse flow.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] RELATIONSHIP BETWEEN CORONARY PRESSURE DISTAL TO A STENOSIS AND DISTRIBUTION OF TRANSMURAL BLOOD-FLOW
    MCHALE, PA
    RANKIN, JS
    GREENFIELD, JC
    CIRCULATION, 1975, 52 (04) : 215 - 215
  • [22] DETAILS OF CORONARY STENOSIS MORPHOLOGY INFLUENCE ITS HEMODYNAMIC SEVERITY AND DISTAL FLOW RESERVE
    FEDELE, FA
    SHARAF, B
    MOST, AS
    GEWIRTZ, H
    CIRCULATION, 1989, 80 (03) : 636 - 642
  • [23] Numerical technique of blood flow through catheterized arteries with overlapping stenosis
    El Kot, M. A.
    Abbas, W.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2017, 20 (01) : 45 - 58
  • [24] Acoustic noise of the turbulent blood flow through varying degrees of arterial stenosis:: numerical study
    Góral-Wójcicka, A
    Malota, Z
    Nawrat, Z
    Borgiel, W
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2004, 20 : 80 - 82
  • [25] Numerical simulation of turbulent flow through series stenoses
    Lee, TS
    Liao, W
    Low, HT
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN FLUIDS, 2003, 42 (07) : 717 - 740
  • [26] CORONARY STENOSIS LOCATION AND DISTAL BRANCHES MAY INFLUENCE THE STENOSIS EVOLUTION
    CHURCHWELL, AL
    ABOUELNASR, DM
    JONES, SA
    GIDDENS, DP
    ARTERIOSCLEROSIS, 1990, 10 (05): : A829 - A829
  • [27] INFLUENCE OF PROXIMAL STENOSIS, DISTAL STENOSIS AND MEAN BLOOD-FLOW ON EARLY PATENCY OF VEIN BYPASS GRAFTS AN EXPERIMENTAL-STUDY
    BOUCHIERHAYES, D
    FITZGERALD, PAM
    IRISH JOURNAL OF MEDICAL SCIENCE, 1977, 146 (01) : 15 - 19
  • [28] A numerical study of flow over mild stenoses
    Mapara, N
    Steinman, DA
    Holdsworth, DW
    Roach, MR
    PROCEEDINGS OF THE 1996 FIFTEENTH SOUTHERN BIOMEDICAL ENGINEERING CONFERENCE, 1996, : 99 - 102
  • [29] Numerical study of pulsating flow through a tapered artery with stenosis
    Liu, GT
    Wang, XJ
    Ai, BQ
    Liu, LG
    CHINESE JOURNAL OF PHYSICS, 2004, 42 (04) : 401 - 409
  • [30] EFFECT OF PERFUSION-PRESSURE DISTAL TO A CORONARY STENOSIS ON TRANSMURAL MYOCARDIAL BLOOD-FLOW
    BACHE, RJ
    SCHWARTZ, JS