ASSESSMENT OF SPECTRAL DOPPLER FOR AN ARRAY-BASED PRECLINICAL ULTRASOUND SCANNER USING A ROTATING PHANTOM

被引:7
|
作者
Kenwright, David A. [1 ]
Anderson, Tom [1 ]
Moran, Carmel M. [1 ]
Hoskins, Peter R. [1 ]
机构
[1] Univ Edinburgh, Ctr Cardiovasc Sci, Edinburgh EH16 4TJ, Midlothian, Scotland
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2015年 / 41卷 / 08期
关键词
Doppler ultrasound; Blood velocity; High-frequency ultrasound; Preclinical ultrasound; Doppler phantom; TISSUE-MIMICKING MATERIAL; BLOOD-FLOW; FREQUENCY; ATTENUATION; SPEED; SOUND; MHZ;
D O I
10.1016/j.ultrasmedbio.2015.04.006
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Velocity measurement errors were investigated for an array-based preclinical ultrasound scanner (Vevo 2100, FUJIFILM VisualSonics, Toronto, ON, Canada). Using a small-size rotating phantom made from a tissue-mimicking material, errors in pulse-wave Doppler maximum velocity measurements were observed. The extent of these errors was dependent on the Doppler angle, gate length, gate depth, gate horizontal placement and phantom velocity. Errors were observed to be up to 172% at high beam-target angles. It was found that small gate lengths resulted in larger velocity errors than large gate lengths, a phenomenon that has not previously been reported (e.g., for a beam-target angle of 0 degrees, the error was 27.8% with a 0.2-mm gate length and 5.4% with a 0.98-mm gate length). The error in the velocity measurement with sample volume depth changed depending on the operating frequency of the probe. Some edge effects were observed in the horizontal placement of the sample volume, indicating a change in the array aperture size. The error in the velocity measurements increased with increased phantom velocity, from 22% at 2.4 cm/s to 30% at 26.6 cm/s. To minimise the impact of these errors, an angle-dependent correction factor was derived based on a simple ray model of geometric spectral broadening. Use of this angle-dependent correction factor reduces the maximum velocity measurement errors to <25% in all instances, significantly improving the current estimation of maximum velocity from pulse-wave Doppler ultrasound. (E-mail: da.kenwright@gmail.com) (C) 2015 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:2232 / 2239
页数:8
相关论文
共 50 条
  • [1] ASSESSMENT OF SPECTRAL DOPPLER IN PRECLINICAL ULTRASOUND USING A SMALL-SIZE ROTATING PHANTOM
    Yang, Xin
    Sun, Chao
    Anderson, Tom
    Moran, Carmel M.
    Hadoke, Patrick W. F.
    Gray, Gillian A.
    Hoskins, Peter R.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (08): : 1491 - 1499
  • [2] A NEW 15-50 MHz ARRAY-BASED MICRO-ULTRASOUND SCANNER FOR PRECLINICAL IMAGING
    Foster, F. Stuart
    Mehi, James
    Lukacs, Marc
    Hirson, Desmond
    White, Chris
    Chaggares, Chris
    Needles, Andrew
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2009, 35 (10): : 1700 - 1708
  • [3] A Phantom Study to Characterize a Doppler Ultrasound Scanner for Application in Prostate Brachytherapy
    Sandhu, G.
    Khan, R.
    Dunscombe, P.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [4] Sample volume misregistration in linear array-based dual beam Doppler ultrasound systems
    Steel, R
    Fish, PJ
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2003, 50 (07) : 836 - 847
  • [5] Using Bedside Spectral Doppler Ultrasound for the Assessment of Patients With Thyrotoxicosis
    Morkos, Michael
    Raju, Karishma Datla
    Ibrahim, Katherine
    ENDOCRINE PRACTICE, 2024, 30 (05) : 465 - 469
  • [6] Spectral Enhancement of a SiPM Array-Based Radiation Detector
    Harn, R.
    Osovizky, A.
    Kadmon, Y.
    Rotman, S.
    Kopeika, N.
    Ghelman, M.
    ANIMMA 2021 - ADVANCEMENTS IN NUCLEAR INSTRUMENTATION MEASUREMENT METHODS AND THEIR APPLICATIONS, 2021, 253
  • [7] Comparison and optimisation of fast array-based ultrasound testing
    Prashar, K.
    Weston, M.
    Drinkwater, B.
    INSIGHT, 2021, 63 (04) : 209 - 218
  • [8] Comparison and optimisation of fast array-based ultrasound testing
    Prashar K.
    Weston M.
    Drinkwater B.
    Prashar, K. (kanav.prashar@bristol.ac.uk), 1600, British Institute of Non-Destructive Testing (63): : 209 - 218
  • [9] An Array-Based Sensor for Seafood Freshness Assessment
    Gonzalez-Martin, Anuncia
    Lewis, Brian
    Raducanu, Marius
    Kim, Jinseong
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2010, 31 (11) : 3084 - 3092
  • [10] Temporal and spectral dispersion of an optical source using a micromirror array-based streak camera
    Benton, David M.
    OPTICAL ENGINEERING, 2022, 61 (11)