ASSESSMENT OF SPECTRAL DOPPLER FOR AN ARRAY-BASED PRECLINICAL ULTRASOUND SCANNER USING A ROTATING PHANTOM

被引:7
|
作者
Kenwright, David A. [1 ]
Anderson, Tom [1 ]
Moran, Carmel M. [1 ]
Hoskins, Peter R. [1 ]
机构
[1] Univ Edinburgh, Ctr Cardiovasc Sci, Edinburgh EH16 4TJ, Midlothian, Scotland
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2015年 / 41卷 / 08期
关键词
Doppler ultrasound; Blood velocity; High-frequency ultrasound; Preclinical ultrasound; Doppler phantom; TISSUE-MIMICKING MATERIAL; BLOOD-FLOW; FREQUENCY; ATTENUATION; SPEED; SOUND; MHZ;
D O I
10.1016/j.ultrasmedbio.2015.04.006
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Velocity measurement errors were investigated for an array-based preclinical ultrasound scanner (Vevo 2100, FUJIFILM VisualSonics, Toronto, ON, Canada). Using a small-size rotating phantom made from a tissue-mimicking material, errors in pulse-wave Doppler maximum velocity measurements were observed. The extent of these errors was dependent on the Doppler angle, gate length, gate depth, gate horizontal placement and phantom velocity. Errors were observed to be up to 172% at high beam-target angles. It was found that small gate lengths resulted in larger velocity errors than large gate lengths, a phenomenon that has not previously been reported (e.g., for a beam-target angle of 0 degrees, the error was 27.8% with a 0.2-mm gate length and 5.4% with a 0.98-mm gate length). The error in the velocity measurement with sample volume depth changed depending on the operating frequency of the probe. Some edge effects were observed in the horizontal placement of the sample volume, indicating a change in the array aperture size. The error in the velocity measurements increased with increased phantom velocity, from 22% at 2.4 cm/s to 30% at 26.6 cm/s. To minimise the impact of these errors, an angle-dependent correction factor was derived based on a simple ray model of geometric spectral broadening. Use of this angle-dependent correction factor reduces the maximum velocity measurement errors to <25% in all instances, significantly improving the current estimation of maximum velocity from pulse-wave Doppler ultrasound. (E-mail: da.kenwright@gmail.com) (C) 2015 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:2232 / 2239
页数:8
相关论文
共 50 条
  • [41] Automated performance assessment of ultrasound systems using a dynamic phantom
    Joy, J.
    Riedel, F.
    Valente, A. A.
    Cochran, S.
    Corner, G. A.
    ULTRASOUND, 2014, 22 (04) : 199 - 204
  • [42] Realtime clinically-oriented array-based in vivo combined photoacoustic and power Doppler imaging
    Harrison, Tyler
    Jeffery, Dean
    Wiebe, Edward
    Zemp, Roger J.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2014, 2014, 8943
  • [43] In vivo imaging of inducible tyrosinase gene expression with an ultrasound array-based photoacoustic system
    Harrison, Tyler
    Paproski, Robert J.
    Zemp, Roger J.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2012, 2012, 8223
  • [44] Activity assessment in morphea using color Doppler ultrasound
    Wortsman, Ximena
    Wortsman, Jacobo
    Sazunic, Ivo
    Carreno, Laura
    JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 2011, 65 (05) : 942 - 948
  • [45] COMPARING THE POWER DOPPLER MODALITY OF 5 ULTRASOUND MACHINES USING A MICROVESSEL FLOW PHANTOM
    Ten Cate, D. F.
    Luime, J. J.
    van der Ven, M.
    Hazes, J. M. W.
    Kooiman, K.
    de Jong, N.
    Bosch, J. G.
    ANNALS OF THE RHEUMATIC DISEASES, 2013, 72 : 747 - 748
  • [46] AN APPROACH TO QUANTITATIVE DOPPLER ECHOCARDIOGRAPHY USING A PHASED-ARRAY SECTOR SCANNER AND A 128-CHANNEL DOPPLER INSTRUMENT
    VIELI, A
    JENNI, R
    ANILIKER, M
    KRAYENBUEHL, HP
    ULTRASONIC IMAGING, 1982, 4 (02) : 195 - 195
  • [47] Beam distortion in Doppler ultrasound flow test rigs: Measurement using a string phantom
    Steel, R
    Fish, PJ
    PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 3304 - 3307
  • [48] Micro array-based DNA resequencing using 3' blocked primers
    Sram, Jakub
    Sommer, Steve S.
    Liu, Qiang
    ANALYTICAL BIOCHEMISTRY, 2008, 374 (01) : 41 - 47
  • [49] Array-based Emitter Localization Using a VTOL UAV Carried Sensor
    Steffes, Christian
    Allmann, Clemens
    Oispuu, Marc
    2020 IEEE INTERNATIONAL CONFERENCE ON MULTISENSOR FUSION AND INTEGRATION FOR INTELLIGENT SYSTEMS (MFI), 2020, : 127 - 132
  • [50] Development of a multi-spectral scanner using LED array for digital color proof
    Yamamoto, Shoji
    Tsumura, Norimichi
    Nakaguchi, Toshiya
    Miyake, Yoichi
    JOURNAL OF IMAGING SCIENCE AND TECHNOLOGY, 2007, 51 (01) : 61 - 69