Spectral Enhancement of a SiPM Array-Based Radiation Detector

被引:0
|
作者
Harn, R. [1 ,3 ]
Osovizky, A. [1 ,2 ]
Kadmon, Y. [1 ]
Rotman, S. [3 ]
Kopeika, N. [3 ]
Ghelman, M. [1 ,3 ]
机构
[1] Nucl Res Ctr Negev, Beer Sheva, Israel
[2] Rotem Ind Ltd, Radiat Detect Dept, Dimona, Israel
[3] Ben Gurion Univ Negev, Sch Elect & Comp Engn, Beer Sheva, Israel
关键词
SiPM; Array; Radiation detectors; SNR; Breakdown Voltage; GAIN-CONTROL;
D O I
10.1051/epjconf/202125311007
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Silicon Photomultipliers (SiPMs) have many advantages when used in radiation detectors. Low bias voltage, compactness and immunity to electromagnetic interference are among their prominent benefits. However, due to their small size, usually an array of SiPM components is required in order to cover the coupling surface area of a scintillator. Since the SiPM is a semiconductor, biased in a reversed voltage, gain variation and strong temperature dependence are introduced. As a result, SiPM-based detectors, particularly an array of SiPMs, undergo spectral signal to noise ratio reduction. This work studies the effect of the SiPM breakdown voltage variation on the obtained energy spectrum and proposes an electronic approach to overcome this technological drawback. This developed technology provides an adequate temperature-dependent, commonly distributed high bias voltage and an individual offset-voltage fine tuning that enables adjustment of all the SiPM components to their optimum operating points. Power-wise it is beneficial to operate SiPM at lower voltages, where undesirable gain variation is more dominant. The proposed solution enables working at lower bias voltages, which provides lower power consumption and better radiation hardness, while yielding an enhanced spectrum resolution. The proposed electronic approach enhances the obtained spectra, reducing the noise threshold by 16 % when working at 1 V overvoltage. Hence provides an enhanced signal to noise ratio over the traditional biasing methods.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] n/? discrimination of SiPM array-based CLYC detector
    Wang, Chenger
    Sun, Xilei
    Yu, Jinqiu
    Lv, Junguang
    Deng, Yong
    Li, Junjie
    Jiang, Huan
    Luo, Liang
    Fan, Xiaoxue
    Gu, Fengbo
    Qi, Xiaohui
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1036
  • [2] Simulation of a neutron imaging detector prototype based on SiPM array readout
    Tang, Mengjiao
    Zhang, Lianjun
    Tang, Bin
    He, Gaokui
    Huang, Chang
    Zhao, Jiangbin
    Liu, Yang
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2023, 55 (09) : 3133 - 3139
  • [3] A novel, SiPM-array-based, monolithic scintillator detector for PET
    Schaart, Dennis R.
    van Dam, Herman T.
    Seifert, Stefan
    Vinke, Ruud
    Dendooven, Peter
    Lohner, Herbert
    Beekman, Freek J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (11): : 3501 - 3512
  • [4] Design the of X-ray backscatter array detector based on SiPM
    Li, Weijiao
    Wu, Xiaomei
    Wang, Weiqi
    Shen, Tianming
    Chen, Jiamin
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2016, 37 (05): : 1034 - 1041
  • [5] A Novel TOF-PET Detector Based on SiPM and Cherenkov Radiation
    Liu, Xiao
    Xu, Tianpeng
    Xia, Yan
    Ma, Tianyu
    Liu, Yaqiang
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [6] FDM array-based dual channel speech enhancement method
    Cui, Weiwei
    Cao, Zhigang
    Su, Yongtao
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2008, 48 (07): : 1135 - 1139
  • [7] Investigation of the required detector distance in array-based treatment plan verifications
    Stedem, A.
    Quast, J.
    Gottschlag, H.
    Schonfeld, A. A.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1347 - S1348
  • [8] First results of an ASIC controlled γ-detector based on a SiPM-array and a monolithic LYSO
    Conde, P.
    Gonzalez, A. J.
    Hernandez, L.
    Moliner, L.
    Orero, A.
    Rodriguez, M. J.
    Sanchez, F.
    Soriano, A.
    Vidal, L. F.
    Benlloch, J. M.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 412 - 414
  • [9] A Compact Neutron Detector Based on the use of a SiPM Detector
    Foster, Mark
    Ramsden, David
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 1157 - +
  • [10] Substantial increase in detection efficiency for filter array-based spectral sensors
    Kobylinskiy, Aliaksei
    Laue, Benjamin
    Foerster, Erik
    Hoefer, Bernd
    Shen, Yannan
    Hillmer, Hartmut
    Brunner, Robert
    APPLIED OPTICS, 2020, 59 (08) : 2443 - 2451