Magnetic Resonance Imaging of Surgical Implants Made from Weak Magnetic Materials

被引:22
|
作者
Gogola, D. [1 ]
Krafcik, A. [1 ]
Strbak, O. [1 ]
Frollo, I. [1 ]
机构
[1] SAS, Inst Measurement Sci, SK-84104 Bratislava, Slovakia
来源
MEASUREMENT SCIENCE REVIEW | 2013年 / 13卷 / 04期
关键词
NMR imaging; field calculation; metal artifact; surgery implants; MRI; SYSTEM;
D O I
10.2478/msr-2013-0026
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Materials with high magnetic susceptibility cause local inhomogeneities in the main field of the magnetic resonance (MR) tomograph. These inhomogeneities lead to loss of phase coherence, and thus to a rapid loss of signal in the image. In our research we investigated inhomogeneous field of magnetic implants such as magnetic fibers, designed for inner suture during surgery. The magnetic field inhomogeneities were studied at low magnetic planar phantom, which was made from four thin strips of magnetic tape, arranged grid-wise. We optimized the properties of imaging sequences with the aim to find the best setup for magnetic fiber visualization. These fibers can be potentially exploited in surgery for internal stitches. Stitches can be visualized by the magnetic resonance imaging (MRI) method after surgery. This study shows that the imaging of magnetic implants is possible by using the low field MRI systems, without the use of complicated post processing techniques (e.g., IDEAL).
引用
收藏
页码:165 / 168
页数:4
相关论文
共 50 条
  • [41] Magnetic resonance imaging in patients with dental implants: A clinical report
    Devge, C
    Tjellstrom, A
    Nellstrom, H
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 1997, 12 (03) : 354 - 359
  • [42] Magnetic resonance imaging of breast implants: Optimizing tissue contrast
    Almuqbel, Mustafa M.
    Palmer, Nick J.
    Jenkins, Anika
    Keenan, Ross J.
    Melzer, Tracy R.
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2023, 54 (01) : 9 - 15
  • [43] Effects of magnetic resonance imaging fields on upper eyelid implants
    Schrom, T
    Bauknecht, H
    Berghaus, A
    Scherer, H
    HNO, 2005, 53 (08) : 741 - 746
  • [44] Safety of orthopedic implants in magnetic resonance imaging: An experimental verification
    Kumar, Ritabh
    Lerski, Richard A.
    Gandy, Stephen
    Clift, Benedict A.
    Abboud, Rami J.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2006, 24 (09) : 1799 - 1802
  • [45] Fusion of magnetic resonance angiography and magnetic resonance Imaging for surgical planning for meningioma - Technical note
    Kashimura, Hiroshi
    Ogasawara, Kuniaki
    Arai, Hiroshi
    Beppu, Takaaki
    Inoue, Takashi
    Takahashi, Tsutomu
    Matsuda, Koichi
    Takahashi, Yujiro
    Fujiwara, Shunrou
    Ogawa, Akira
    NEUROLOGIA MEDICO-CHIRURGICA, 2008, 48 (09) : 418 - 421
  • [46] ABSENCE OF RADIOFREQUENCY HEATING FROM AUDITORY IMPLANTS DURING MAGNETIC-RESONANCE-IMAGING
    CHOU, CK
    MCDOUGALL, JA
    CHAN, KW
    BIOELECTROMAGNETICS, 1995, 16 (05) : 307 - 316
  • [47] Susceptibility artifacts induced by crowns of different materials with prepared teeth and titanium implants in magnetic resonance imaging
    Gao, Xiaomeng
    Wan, Qianbing
    Gao, Qingping
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [48] Susceptibility artifacts induced by crowns of different materials with prepared teeth and titanium implants in magnetic resonance imaging
    Xiaomeng Gao
    Qianbing Wan
    Qingping Gao
    Scientific Reports, 12
  • [49] Magnetic resonance imaging safety of surgical clips and staples
    De Silva, S.
    Bampoe, S.
    Scott, M.
    ANAESTHESIA, 2015, 70 (12) : 1463 - 1463
  • [50] Magnetic Resonance Imaging Monsters and Surgical Vampires reply
    Stuebing, Elizabeth Ann
    ARCHIVES OF SURGERY, 2011, 146 (11) : 1333 - 1334