Measurements of body impedance for ESD

被引:0
|
作者
Wu, ZC
Lu, SG
机构
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
High voltage, short duration Electrostatic discharge (ESD) measurement of human body impedance have been accomplished for different paths through the body. Skirt contact impedance and internal body impedance between various locations on the body were examined. Voltages of 1000 to 5000V were applied giving peak currents of 2.0 to 10A. The current waveforms had time constants 0.25 to 1.25 mu s. The short time constants are consistent with safely requirements. The body impedance between the palm of the hand and the sole of the foot was found to he about 520 to 550 Omega.
引用
收藏
页码:318 / 320
页数:3
相关论文
共 50 条
  • [41] Accuracy of bioelectrical impedance for measurements of body composition in Hispanic American elderly women
    Bermudez, OI
    Valtuena, S
    Castaneda, C
    Waitekus, AB
    Sheahan, CA
    Tucker, KL
    Kehayias, JJ
    FASEB JOURNAL, 2001, 15 (05): : A1002 - A1002
  • [42] HOW VALID ARE BIOELECTRIC IMPEDANCE MEASUREMENTS IN BODY-COMPOSITION STUDIES - RESPONSE
    COHN, S
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1986, 44 (02): : 307 - 308
  • [43] In vivo impedance measurements on nerves and surrounding skeletal muscles in rats and human body
    Prokhorov, E
    Llamas, F
    Morales-Sánchez, E
    González-Hernández, J
    Prokhorov, A
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2002, 40 (03) : 323 - 326
  • [44] Effects of Acute Water Intake on Body Composition Measurements by Bioelectric Impedance Analysis
    Ozdenk, Cagri
    INTERNATIONAL JOURNAL OF APPLIED EXERCISE PHYSIOLOGY, 2020, 9 (04): : 38 - 42
  • [45] EVALUATION OF IMPEDANCE MEASUREMENTS IN HUMANS FOR ASSESSING BODY-WATER, FAT AND MUSCLE
    FERRY, M
    BOULIER, A
    FRICKER, J
    GASTROENTEROLOGIE CLINIQUE ET BIOLOGIQUE, 1990, 14 (04): : 371 - 371
  • [46] Uncertainties in Charge Measurements of ESD Risk Assessment
    Viheriakoski, Toni
    Kohtamaki, Jari
    Peltoniemi, Terttu
    Tamminen, Pasi
    2015 37TH ELECTRICAL OVERSTRESS/ELECTROSTATIC DISCHARGE SYMPOSIUM (EOS/ESD), 2015,
  • [47] Different impedance indexes in segmental and whole-body measurements in peritoneal dialysis patients
    Nescolarde, L.
    Donate, T.
    Garcia, M. A.
    Rosell-Ferrer, J.
    13TH INTERNATIONAL CONFERENCE ON ELECTRICAL BIOIMPEDANCE AND THE 8TH CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY 2007, 2007, 17 : 779 - +
  • [48] VALIDATION OF BIOELECTRICAL-IMPEDANCE MEASUREMENTS AS A METHOD TO ESTIMATE BODY-WATER COMPARTMENTS
    LICHTENBELT, WDV
    WESTERTERP, KR
    WOUTERS, L
    LUIJENDIJK, SCM
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1994, 60 (02): : 159 - 166
  • [49] The influence of gravity on electrical impedance tomography measurements during upper body position change
    Yang, Lin
    Gao, Zhijun
    Cao, Xinsheng
    Fu, Feng
    Moller, Knut
    Frerichs, Inez
    Dai, Meng
    Zhao, Zhanqi
    HELIYON, 2023, 9 (05)
  • [50] Multifrequency bioelectric impedance measurements for predicting body water compartments in Duchenne muscular dystrophy
    Bedogni, G
    Merlini, L
    Ballestrazzi, A
    Severi, S
    Battistini, N
    NEUROMUSCULAR DISORDERS, 1996, 6 (01) : 55 - 60