Aortic valve replacement with stentless porcine bioprostheses

被引:22
|
作者
David, TE [1 ]
机构
[1] Toronto Hosp, Div Cardiovasc Surg, Toronto, ON M5T 2S8, Canada
关键词
D O I
10.1111/j.1540-8191.1998.tb01096.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The implantation of stentless porcine valves (SPVs) is technically more demanding than implantation of stented bioprosthetic valves. Implantation of the Toronto SPV bioprosthesis requires an understanding of the relationships between the leaflets and the aortic annulus and sinotubular junction. In addition to proper alignment of the three commissures within the aortic root, the diameter of sinotubular junction should not exceed the external diameter of the porcine aortic valve after completion of the operation. The Medtronic Freestyle porcine aortic root bioprosthesis can be used for subcoronary implantation as well as for aortic root replacement. Degenerative calcification of a tricuspid aortic valve is the most common cause of aortic valve disease in older patients. Implantation of stentless valves in the subcoronary position is usually feasible because the geometry of the aortic root is well maintained in these patients. The bicuspid aortic valve is the second most common cause of aortic valve disease in older patients and the most common in younger patients. These patients frequently have dilated aortic root, and the Medtronic Freestyle bioprosthesis is ideal for implantation using the root inclusion technique, Stentless porcine bioprostheses are minimally obstructive and associated with low mean systolic gradients. In addition, they have better hemodynamic performance during exercise than stented bioprostheses. For these reasons, patient-prosthesis mismatch has not been described with stentless valves. Left ventricular function after aortic valve replacement appears to be better with stentless than with stented bioprostheses. Comparative, nonrandomized studies of aortic valve replacement with stented and stentless valves suggest that the risk of cardiac death is reduced with stentless valves and the rates of valve-related complications also appear to be lower. What remains unknown is whether stentless valves are more durable than stented ones.
引用
收藏
页码:344 / 351
页数:8
相关论文
共 50 条
  • [41] Stentless bioprostheses: a versatile and durable solution in extensive aortic valve endocarditisaEuro
    Schneider, Adriaan W.
    Hazekamp, Mark G.
    Versteegh, Michel I. M.
    Bruggemans, Eline F.
    Holman, Eduard R.
    Klautz, Robert J. M.
    Braun, Jerry
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2016, 49 (06) : 1699 - 1704
  • [42] Aortic valve replacement with stentless and stented porcine valves: A case-match study
    David, TE
    Puschmann, R
    Ivanov, J
    Bos, J
    Armstrong, S
    Feindel, CM
    Scully, HE
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 116 (02): : 236 - 241
  • [43] PRELIMINARY EXPERIENCE WITH THE TORONTO SPV STENTLESS PORCINE BIOPROSTHESIS FOR AORTIC-VALVE REPLACEMENT
    KONERTZ, W
    HERRMANN, M
    KNAUTH, M
    STABENOW, I
    DAVID, T
    THORACIC AND CARDIOVASCULAR SURGEON, 1994, 42 (01): : 36 - 39
  • [44] Medium-term results of stentless bioprostheses for aortic valve replacement results in a series of 97 patients.
    Hubaut, JJ
    Baron, O
    Rached, NA
    Al Habash, O
    Despins, P
    Duveau, D
    Michaud, JL
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 2001, 94 (04): : 269 - 275
  • [45] Aortic valve replacement in the elderly: Prospective randomised study between homograft and Toronto stentless porcine valve
    Nyawo, B
    Bakhai, A
    Edwards, S
    Khaghani, A
    Pepper, J
    Yacoub, M
    CIRCULATION, 2001, 104 (17) : 760 - 760
  • [46] Stentless aortic valve replacement in elderly patients
    Gelsomino, S
    Da Col, P
    Morocutti, G
    Frassani, R
    Porreca, L
    Minen, G
    Livi, U
    CARDIOVASCULAR SURGERY, 2002, 10 (03): : 233 - 237
  • [47] Outcome of Aortic Valve Replacement with Bioprostheses in the Elderly
    Suojaranta-Ylinen, Raili T.
    Soisalon-Soininen, Sari
    Kaartinen, Maija
    Maasilta, Paula K.
    Vainikka, Tiina L.
    Vento, Antti E.
    Salminen, Ulla-Stina
    JOURNAL OF HEART VALVE DISEASE, 2009, 18 (05): : 514 - 523
  • [48] Truly stentless autologous pericardial aortic valve replacement: An alternative to standard aortic valve replacement
    Chan, K. M. John
    Rahman-Haley, Shelley
    Mittal, Tarun K.
    Gavino, Jemyrr A.
    Dreyfus, Gilles D.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2011, 141 (01): : 276 - 283
  • [49] Stentless bioprosthetic aortic valve replacement after valve-sparing aortic root replacement
    Ikonomidis, JS
    Miller, DC
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 124 (04): : 848 - 851
  • [50] Stentless porcine bioprostheses for all types of aortic root pathology - Conference discussion
    Carpentier, A
    Sidiropoulos, A
    Pepper, J
    Palatianos, G
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1997, 11 (05) : 920 - 921