Aortic valve replacement with stentless porcine bioprostheses

被引:22
|
作者
David, TE [1 ]
机构
[1] Toronto Hosp, Div Cardiovasc Surg, Toronto, ON M5T 2S8, Canada
关键词
D O I
10.1111/j.1540-8191.1998.tb01096.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The implantation of stentless porcine valves (SPVs) is technically more demanding than implantation of stented bioprosthetic valves. Implantation of the Toronto SPV bioprosthesis requires an understanding of the relationships between the leaflets and the aortic annulus and sinotubular junction. In addition to proper alignment of the three commissures within the aortic root, the diameter of sinotubular junction should not exceed the external diameter of the porcine aortic valve after completion of the operation. The Medtronic Freestyle porcine aortic root bioprosthesis can be used for subcoronary implantation as well as for aortic root replacement. Degenerative calcification of a tricuspid aortic valve is the most common cause of aortic valve disease in older patients. Implantation of stentless valves in the subcoronary position is usually feasible because the geometry of the aortic root is well maintained in these patients. The bicuspid aortic valve is the second most common cause of aortic valve disease in older patients and the most common in younger patients. These patients frequently have dilated aortic root, and the Medtronic Freestyle bioprosthesis is ideal for implantation using the root inclusion technique, Stentless porcine bioprostheses are minimally obstructive and associated with low mean systolic gradients. In addition, they have better hemodynamic performance during exercise than stented bioprostheses. For these reasons, patient-prosthesis mismatch has not been described with stentless valves. Left ventricular function after aortic valve replacement appears to be better with stentless than with stented bioprostheses. Comparative, nonrandomized studies of aortic valve replacement with stented and stentless valves suggest that the risk of cardiac death is reduced with stentless valves and the rates of valve-related complications also appear to be lower. What remains unknown is whether stentless valves are more durable than stented ones.
引用
收藏
页码:344 / 351
页数:8
相关论文
共 50 条
  • [21] AORTIC-VALVE REPLACEMENT WITH A STENTLESS PORCINE BIOPROSTHESIS - MULTICENTER TRIAL
    DELRIZZO, DF
    GOLDMAN, BS
    DAVID, TE
    [J]. CANADIAN JOURNAL OF CARDIOLOGY, 1995, 11 (07) : 597 - 603
  • [22] ECHOCARDIOGRAPHIC ASSESSMENT OF AORTIC-VALVE REPLACEMENT WITH STENTLESS PORCINE XENOGRAFTS
    MELONI, L
    RICCHI, A
    CIRIO, E
    FALCHI, S
    ABBRUZZESE, PA
    ARU, GM
    MARTELLI, V
    ROSS, D
    CHERCHI, A
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1995, 76 (04): : 294 - 296
  • [23] Prosthetic Valve Endocarditis After Aortic Valve Replacement With Bovine Versus Porcine Bioprostheses
    Glaser, Natalie
    Sartipy, Ulrik
    Dismorr, Michael
    [J]. JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2024, 13 (01):
  • [24] Stentless vs Stented Aortic Valve Bioprostheses in the Small Aortic Root
    Wollersheim, Laurens W.
    Li, Wilson W.
    Kaya, Abdullah
    Bouma, Berto J.
    Driessen, Antoine H.
    van Boven, Vvim J.
    van der Meulen, Jan
    de Mol, Bas A.
    [J]. SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2016, 28 (02) : 390 - 397
  • [25] Midterm outcomes of subcoronary stentless porcine valve versus stented aortic valve replacement
    Aranda-Michel, Edgar
    Bianco, Valentino
    Dufendach, Keith
    Kilic, Arman
    Habertheuer, Andreas
    Humar, Rishab
    Navid, Forozan
    Wang, Yisi
    Sultan, Ibrahim
    [J]. JOURNAL OF CARDIAC SURGERY, 2020, 35 (11) : 2950 - 2956
  • [26] Dynamic obstruction, an unusual complication after aortic valve replacement with a stentless porcine valve
    Radboud P.M. van Roosmalen
    Leo H.B. Baur
    Jerry Braun
    Douwe E. Atsma
    Mark G. Hazekamp
    Ernst E. van der Wall
    Hans A. Huysmans
    [J]. The International Journal of Cardiac Imaging, 1999, 15 : 209 - 214
  • [27] Dynamic obstruction, an unusual complication after aortic valve replacement with a stentless porcine valve
    van Roosmalen, RPM
    Baur, LHB
    Braun, J
    Atsma, DE
    Hazekamp, MG
    van der Wall, EE
    Huysmans, HA
    [J]. INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1999, 15 (03): : 209 - 214
  • [28] Transcatheter aortic valve-in-valve implantation in failed stentless bioprostheses
    Huczek, Zenon
    Grodecki, Kajetan
    Scislo, Piotr
    Wilczek, Krzysztof
    Jagielak, Dariusz
    Fil, Wojciech
    Kubler, Piotr
    Olszowka, Piotr
    Dabrowski, Maciej
    Frank, Marek
    Grygier, Marek
    Kidawa, Michal
    Wilimski, Radoslaw
    Zelazowska, Katarzyna
    Witkowski, Adam
    Kochman, Janusz
    Zembala, Marian
    Opolski, Grzegorz
    Dvir, Danny
    Wojakowski, Wojciech
    [J]. JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2018, 31 (06) : 861 - 869
  • [29] Hancock versus stentless bioprostheses for aortic valve replacement in patients older than 75 years
    Santini, F
    Bertolini, P
    Montalbano, G
    Vecchi, B
    Pessotto, R
    Prioli, A
    Mazzucco, A
    [J]. ANNALS OF THORACIC SURGERY, 1998, 66 (06): : S99 - S103
  • [30] Stentless porcine bioprostheses for all types of aortic root pathology
    Sidiropoulos, A
    Hotz, H
    Tschesnow, J
    Konertz, W
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1997, 11 (05) : 917 - 920