Radiofrequency catheter ablation using cooled electrodes: Impact of irrigation flow rate and catheter contact pressure on lesion dimensions

被引:76
|
作者
Weiss, C
Antz, M
Eick, O
Eshagzaiy, K
Meinertz, T
Willems, S
机构
[1] Univ Hamburg, Hosp Eppendorf, Dept Cardiol, D-20246 Hamburg, Germany
[2] Gen Hosp St Georg, Hamburg, Germany
[3] Bakken Res Ctr, Maastricht, Netherlands
来源
关键词
catheter ablation; ablation electrodes; electrophysiology;
D O I
10.1046/j.1460-9592.2002.00463.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Irrigation of radiofrequency current (RF) ablation reduces the risk of thrombus formation. The aim of this study was to investigate the impact of different irrigation catheter flow rates and contact pressures from the catheter on the development of lesion dimension and thrombus formation. A thigh muscle preparation was achieved in six sheep to create a cradle that was filled and perfused with heparinized blood (250 mL/min, 37Cdegrees). RF ablation (30 s, 30 W) was initially performed with three different irrigation flow rates (5 mL/min, 10 mL/min, and 20 mL/min) and a perpendicular position (0.1 N contact pressure) of the irrigated ablation catheter ("Sprinklr," Medtronic, Inc., Minneapolis, MN, USA). The next lesions were induced with constant contact pressure of 0.05 Newton (N); 0.1 N; 0.3 and 0.5 N and a parallel or perpendicular orientation of the catheter, respectively. A constant irrigation flow of 10 mL/min was maintained during these RF applications. Cross sections of the lesions were investigated with regard to maximal depth and maximal diameter at and below the surface. During high flow irrigation (20 mL/min) the surface diameter was significantly smaller (0.63 +/- 0.1 cm) compared to irrigation flow rates of 5 mL/min (0.88 +/- 0.2 cm) and 10 mL/min (1 +/- 0.1 cm). Thrombus formation was not observed during any RF application. Only in perpendicular catheter orientations with a contact pressure of 0.5 N were significantly deeper lesions (0.85 +/- 0.12 cm) induced compared to 0.05 N (0.55 +/- 0.02 cm), 0.1 N (0.7 +/- 0.01 cm) and 0.3 N (0.67 +/- 0.01 cm) contact pressure. There was no significant difference in lesion depth with different flow rates. Irrigated RF oblation even with low flow rates and high catheter contact pressure prevented thrombus formation at the electrode. Smaller lesion diameters have been created with high irrigation flow rates. The deeper lesion created with high catheter contact pressure might be caused by a greater power transmission to the tissue.
引用
收藏
页码:463 / 469
页数:7
相关论文
共 50 条
  • [41] RADIOFREQUENCY ABLATION OF VENTRICULAR MYOCARDIUM USING ACTIVE FIXATION AND PASSIVE CONTACT CATHETER DELIVERY SYSTEMS
    AN, H
    SAKSENA, S
    JANSSEN, M
    OSYPKA, P
    AMERICAN HEART JOURNAL, 1989, 118 (01) : 69 - 77
  • [42] Catheter contact area strongly correlates with lesion area in radiofrequency cardiac ablation: an ex vivo porcine heart study
    Kriengsak Masnok
    Nobuo Watanabe
    Journal of Interventional Cardiac Electrophysiology, 2022, 63 : 561 - 572
  • [43] Catheter contact area strongly correlates with lesion area in radiofrequency cardiac ablation: an ex vivo porcine heart study
    Masnok, Kriengsak
    Watanabe, Nobuo
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2022, 63 (03) : 561 - 572
  • [44] Catheter ablation procedure using advanced porous tip contact-force sensing radiofrequency catheter: Impact on healthcare utilization among patients with persistent atrial fibrillation
    Khanna, Rahul
    Doshi, Amit
    Maccioni, Sonia
    Sariki, Meghana
    PHARMACOEPIDEMIOLOGY AND DRUG SAFETY, 2022, 31 : 465 - 466
  • [45] Catheter ablation using advanced porous tip contact force-sensing radiofrequency catheter: Impact on health care utilization among patients with persistent atrial fibrillation
    Doshi, Amit
    Maccioni, Sonia
    Preethi, Sariki Meghana
    Khanna, Rahul
    HEART RHYTHM O2, 2022, 3 (05): : 474 - 481
  • [46] Optimal configurations for bipolar radiofrequency ablation that allow deeper lesion formation: Good catheter-tip cooling, good catheter-tissue contact, and the next approach
    Yoshida, Kentaro
    Nogami, Akihiko
    HEART RHYTHM, 2016, 13 (11) : 2172 - 2173
  • [47] Importance of Catheter Contact Force During Irrigated Radiofrequency Ablation: Evaluation in a Porcine Ex Vivo Model Using a Force-Sensing Catheter
    Thiagalingam, Aravinda
    D'Avila, Andre
    Foley, Lori
    Guerrero, J. Luis
    Lambert, Hendrik
    Leo, Giovanni
    Ruskin, Jeremy N.
    Reddy, Vivek Y.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2010, 21 (07) : 806 - 811
  • [48] Reduced irrigation rate with a more uniformly irrigated radiofrequency ablation catheter creates similar radiofrequency lesions while maintaining an excellent safety profile
    Mcelderry, T.
    Carter, H.
    Brown, J.
    Teplitsky, L.
    EUROPEAN HEART JOURNAL, 2010, 31 : 556 - 556
  • [49] Prediction of radiofrequency ablation lesion formation using a novel temperature sensing technology incorporated in a force sensing catheter
    Rozen, Guy
    Ptaszek, Leon
    Zilberman, Israel
    Cordaro, Kevin
    Heist, E. Kevin
    Beeckler, Christopher
    Altmann, Andres
    Ying, Zhang
    Liu, Zhenjiang
    Ruskin, Jeremy N.
    Govari, Assaf
    Mansour, Moussa
    HEART RHYTHM, 2017, 14 (02) : 248 - 254
  • [50] Characteristics of Radiofrequency Catheter Ablation Lesion Formation in Real Time In Vivo Using Near Field Ultrasound Imaging
    Wright, Matthew
    Harks, Erik
    Deladi, Szabolcs
    Fokkenrood, Steven
    Brink, Rob
    Belt, Harm
    Kolen, Alexander F.
    Rankin, Darrell
    Stoffregen, William
    Cockayne, Debra A.
    Cefalu, Joseph
    Haines, David E.
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2018, 4 (08) : 1062 - 1072