Radiofrequency catheter ablation using cooled electrodes: Impact of irrigation flow rate and catheter contact pressure on lesion dimensions

被引:76
|
作者
Weiss, C
Antz, M
Eick, O
Eshagzaiy, K
Meinertz, T
Willems, S
机构
[1] Univ Hamburg, Hosp Eppendorf, Dept Cardiol, D-20246 Hamburg, Germany
[2] Gen Hosp St Georg, Hamburg, Germany
[3] Bakken Res Ctr, Maastricht, Netherlands
来源
关键词
catheter ablation; ablation electrodes; electrophysiology;
D O I
10.1046/j.1460-9592.2002.00463.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Irrigation of radiofrequency current (RF) ablation reduces the risk of thrombus formation. The aim of this study was to investigate the impact of different irrigation catheter flow rates and contact pressures from the catheter on the development of lesion dimension and thrombus formation. A thigh muscle preparation was achieved in six sheep to create a cradle that was filled and perfused with heparinized blood (250 mL/min, 37Cdegrees). RF ablation (30 s, 30 W) was initially performed with three different irrigation flow rates (5 mL/min, 10 mL/min, and 20 mL/min) and a perpendicular position (0.1 N contact pressure) of the irrigated ablation catheter ("Sprinklr," Medtronic, Inc., Minneapolis, MN, USA). The next lesions were induced with constant contact pressure of 0.05 Newton (N); 0.1 N; 0.3 and 0.5 N and a parallel or perpendicular orientation of the catheter, respectively. A constant irrigation flow of 10 mL/min was maintained during these RF applications. Cross sections of the lesions were investigated with regard to maximal depth and maximal diameter at and below the surface. During high flow irrigation (20 mL/min) the surface diameter was significantly smaller (0.63 +/- 0.1 cm) compared to irrigation flow rates of 5 mL/min (0.88 +/- 0.2 cm) and 10 mL/min (1 +/- 0.1 cm). Thrombus formation was not observed during any RF application. Only in perpendicular catheter orientations with a contact pressure of 0.5 N were significantly deeper lesions (0.85 +/- 0.12 cm) induced compared to 0.05 N (0.55 +/- 0.02 cm), 0.1 N (0.7 +/- 0.01 cm) and 0.3 N (0.67 +/- 0.01 cm) contact pressure. There was no significant difference in lesion depth with different flow rates. Irrigated RF oblation even with low flow rates and high catheter contact pressure prevented thrombus formation at the electrode. Smaller lesion diameters have been created with high irrigation flow rates. The deeper lesion created with high catheter contact pressure might be caused by a greater power transmission to the tissue.
引用
收藏
页码:463 / 469
页数:7
相关论文
共 50 条
  • [21] Contrasting effects of convective flow on catheter ablation lesion size: Cryo versus radiofrequency energy
    Pilcher, Thomas A.
    Saul, J. Philip
    Hlavacek, Anthony M.
    Haemmerich, Dieter
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2008, 31 (03): : 300 - 307
  • [22] CATHETER ABLATION USING RADIOFREQUENCY ENERGY - CONTROL OF LESION VOLUME AND SHAPE BY VARYING POWER AND DURATION OF ABLATION
    GROGAN, EW
    NELLIS, SH
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 9 (02) : A128 - A128
  • [23] Pulsed-Field Ablation in Ventricular Myocardium Using a Focal Catheter The Impact of Application Repetition on Lesion Dimensions
    Yavin, Hagai D.
    Higuchi, Koji
    Sroubek, Jakub
    Younis, Arwa
    Zilberman, Israel
    Anter, Elad
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2021, 14 (09): : E010375
  • [24] Impact of catheter on uroflow rate in pressure-flow study
    张鹏
    武治津
    高居忠
    中华医学杂志(英文版), 2004, (11) : 132 - 134
  • [25] Impact of catheter on uroflow rate in pressure-flow study
    张鹏
    武治津
    高居忠
    Chinese Medical Journal, 2004, (11)
  • [26] Impact of catheter on uroflow rate in pressure-flow study
    Zhang, P
    Wu, ZJ
    Gao, JZ
    CHINESE MEDICAL JOURNAL, 2004, 117 (11) : 1732 - 1734
  • [27] Radiofrequency Catheter Ablation Using Non-Contact Mapping for Inappropriate Sinus Tachycardia
    Chad E. Bonhomme
    Florin T. Deger
    Jeff Schultz
    Steve S. Hsu
    Journal of Interventional Cardiac Electrophysiology, 2004, 10 : 159 - 163
  • [28] Radiofrequency catheter ablation using non-contact mapping for inappropriate sinus tachycardia
    Bonhomme, CE
    Deger, FT
    Schultz, J
    Hsu, SS
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2004, 10 (02) : 159 - 163
  • [29] Open-irrigated laser catheter ablation: influence of catheter irrigation and of contact and noncontact mode of laser application on lesion formation in bovine myocardium
    Helmut P. Weber
    Michaela Sagerer-Gerhardt
    Lasers in Medical Science, 2014, 29 : 1183 - 1187
  • [30] Open-irrigated laser catheter ablation: influence of catheter irrigation and of contact and noncontact mode of laser application on lesion formation in bovine myocardium
    Weber, Helmut P.
    Sagerer-Gerhardt, Michaela
    LASERS IN MEDICAL SCIENCE, 2014, 29 (03) : 1183 - 1187