Radiofrequency catheter ablation using cooled electrodes: Impact of irrigation flow rate and catheter contact pressure on lesion dimensions

被引:76
|
作者
Weiss, C
Antz, M
Eick, O
Eshagzaiy, K
Meinertz, T
Willems, S
机构
[1] Univ Hamburg, Hosp Eppendorf, Dept Cardiol, D-20246 Hamburg, Germany
[2] Gen Hosp St Georg, Hamburg, Germany
[3] Bakken Res Ctr, Maastricht, Netherlands
来源
关键词
catheter ablation; ablation electrodes; electrophysiology;
D O I
10.1046/j.1460-9592.2002.00463.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Irrigation of radiofrequency current (RF) ablation reduces the risk of thrombus formation. The aim of this study was to investigate the impact of different irrigation catheter flow rates and contact pressures from the catheter on the development of lesion dimension and thrombus formation. A thigh muscle preparation was achieved in six sheep to create a cradle that was filled and perfused with heparinized blood (250 mL/min, 37Cdegrees). RF ablation (30 s, 30 W) was initially performed with three different irrigation flow rates (5 mL/min, 10 mL/min, and 20 mL/min) and a perpendicular position (0.1 N contact pressure) of the irrigated ablation catheter ("Sprinklr," Medtronic, Inc., Minneapolis, MN, USA). The next lesions were induced with constant contact pressure of 0.05 Newton (N); 0.1 N; 0.3 and 0.5 N and a parallel or perpendicular orientation of the catheter, respectively. A constant irrigation flow of 10 mL/min was maintained during these RF applications. Cross sections of the lesions were investigated with regard to maximal depth and maximal diameter at and below the surface. During high flow irrigation (20 mL/min) the surface diameter was significantly smaller (0.63 +/- 0.1 cm) compared to irrigation flow rates of 5 mL/min (0.88 +/- 0.2 cm) and 10 mL/min (1 +/- 0.1 cm). Thrombus formation was not observed during any RF application. Only in perpendicular catheter orientations with a contact pressure of 0.5 N were significantly deeper lesions (0.85 +/- 0.12 cm) induced compared to 0.05 N (0.55 +/- 0.02 cm), 0.1 N (0.7 +/- 0.01 cm) and 0.3 N (0.67 +/- 0.01 cm) contact pressure. There was no significant difference in lesion depth with different flow rates. Irrigated RF oblation even with low flow rates and high catheter contact pressure prevented thrombus formation at the electrode. Smaller lesion diameters have been created with high irrigation flow rates. The deeper lesion created with high catheter contact pressure might be caused by a greater power transmission to the tissue.
引用
收藏
页码:463 / 469
页数:7
相关论文
共 50 条
  • [1] Radiofrequency catheter ablation using long coiled electrodes: Impact of irrigation on lesion dimensions and incidence of coagulum formation
    Weiss, C
    Antz, M
    Thuneke, F
    Meinertz, T
    Kuck, KH
    Willems, S
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2001, 24 (06): : 933 - 938
  • [2] Radiofrequency catheter ablation using cooled electrodes: Comparison of different technologies
    Dorwarth, U
    Fiek, M
    Remp, T
    Finkner, K
    Hoffmann, E
    CIRCULATION, 1998, 98 (17) : 436 - 437
  • [3] Role of Catheter Contact Force on Biophysical Properties of the Ablation Lesion Formation in Radiofrequency Catheter Cardiac Ablation
    Masnok, Kriengsak
    Watanabe, Nobuo
    2021 IEEE REGION 10 SYMPOSIUM (TENSYMP), 2021,
  • [4] Atrial Fibrillation Ablation Using a Closed Irrigation Radiofrequency Ablation Catheter
    Golden, Keith
    Mounsey, John Paul
    Chung, Eugene
    Roomiani, Pahresah
    Morse, Michael Andew
    Patel, Ankit
    Gehi, Anil
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (05): : 506 - 513
  • [5] The effect of contact force during radiofrequency catheter ablation using a vibrating catheter: New cooling method for catheter ablation
    Yu, Kaihong
    Yamashita, Tetsui
    Shingyochi, Shigeaki
    Matsumoto, Kazuo
    Komiya, Atsuki
    Ohta, Makoto
    TECHNOLOGY AND HEALTH CARE, 2019, 27 (06) : 589 - 601
  • [6] Economic impact of atrial fibrillation ablation with radiofrequency contact force catheter versus cryoballoon catheter
    Pollak, Scott J.
    Goldstein, Laura
    Daskiran, Mehmet
    Kalsekar, Iftekhar
    Khanna, Rahul
    JOURNAL OF COMPARATIVE EFFECTIVENESS RESEARCH, 2019, 8 (04) : 251 - 264
  • [7] Temperature-controlled irrigated tip radiofrequency catheter ablation: Comparison of in vivo and in vitro lesion dimensions for standard catheter and irrigated tip catheter with minimal infusion rate
    Petersen, HH
    Chen, X
    Pietersen, A
    Svendsen, JH
    Haunso, S
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1998, 9 (04) : 409 - 414
  • [8] Impact of irrigation flow rate and intrapericardial fluid on cooled-tip epicardial radiofrequency ablation
    Aryana, Arash
    O'Neill, Padraig Gearoid
    Pujara, Deep K.
    Singh, Steve K.
    Bowers, Mark R.
    Allen, Shelley L.
    d'Avila, Andre
    HEART RHYTHM, 2016, 13 (08) : 1602 - 1611
  • [9] Effect of catheter movement and contact during application of radiofrequency energy on ablation lesion characteristics
    Matthew D. Olson
    Nicholas Phreaner
    Joseph L. Schuller
    Duy T. Nguyen
    David F. Katz
    Ryan G. Aleong
    Wendy S. Tzou
    Raphael Sung
    Paul D. Varosy
    William H. Sauer
    Journal of Interventional Cardiac Electrophysiology, 2013, 38 : 123 - 129
  • [10] Effect of catheter movement and contact during application of radiofrequency energy on ablation lesion characteristics
    Olson, Matthew D.
    Phreaner, Nicholas
    Schuller, Joseph L.
    Nguyen, Duy T.
    Katz, David F.
    Aleong, Ryan G.
    Tzou, Wendy S.
    Sung, Raphael
    Varosy, Paul D.
    Sauer, William H.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2013, 38 (02) : 123 - 129