The validity of emergency department triage blood pressure measurements

被引:19
|
作者
Cienki, JJ [1 ]
DeLuca, LA [1 ]
Daniel, N [1 ]
机构
[1] Univ Miami, Jackson Mem Hosp, Sch Med, Miami, FL 33316 USA
关键词
blood pressure; emergency medical services; triage; hypertension; automated blood pressure;
D O I
10.1197/j.aem.2003.10.021
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Automated blood pressure (ABP) devices are ubiquitous at emergency department (ED) triage. Previous studies failed to evaluate ABP devices against accepted reference standards or demonstrate triage readings as accurate reflections of blood pressure (BP). This study evaluated ED triage measurements made using an ABP device and assessed agreement between triage BP and BP taken under recommended conditions. Methods: A prospective study was conducted at an urban teaching hospital. Patients were enrolled by convenience sampling. Simultaneous automated and manual triage BPs were obtained using one BP cuff with a Y-tube connector. Research assistants were certified in obtaining manual BP as described by the British Hypertension Society (BHS). Patients were placed in a quiet setting, and manual BP was repeated by American Heart Association (AHA) standards. Data analysis was performed using methods described by Bland and Altman. The ABP device was assessed using Association for the Advancement of Medical Instrumentation (AAMI) and BHS criteria. Results: One hundred seventy-one patients were enrolled. Systolic BP (sBP) range was 81 to 218 mm Hg; diastolic BP (dBP) range was 43 to 130 mm Hg. Automated vs. manual sBP difference was 3.8 +/- 11.2 mm Hg (95% confidence interval [CI] = 2.1 to 5.4); dBP difference was 6.6 +/- 9.0 mm Hg (95% CI = -7.9 to -5.2). Manual triage BP vs. AHA standard SBP difference was 11.6 +/- 12.8 mm Hg (95% CI = 9.1 to 14.1); dBP difference was 9.9 +/- 10.4 mm Hg (95% CI = 7.9 to 12.0). The ABP device failed to meet AAMI criteria and received a BHS rating of "D." Poor operator technique and extraneous patient and operator movement appeared to hamper accuracy. Conclusions: ABP triage measurements show significant discrepancies from a reference standard. Repeat measurements following AHA standards demonstrate significant decreases in the measured blood pressures.
引用
收藏
页码:237 / 243
页数:7
相关论文
共 50 条
  • [21] Emergency department triage revisited
    FitzGerald, Gerard
    Jelinek, George A.
    Scott, Deborah
    Gerdtz, Marie Frances
    EMERGENCY MEDICINE JOURNAL, 2010, 27 (02) : 86 - 92
  • [22] Validity and reliability of a novel Color-Risk Psychiatric Triage in a psychiatric emergency department
    Molina-Lopez, Alejandro
    Bernardo Cruz-Islas, Jeremy
    Palma-Cortes, Mauricio
    Patricia Guizar-Sanchez, Diana
    Yeuh Garfias-Rau, Cesar
    Patricia Ontiveros-Uribe, Martha
    Fresan-Orellana, Ana
    BMC PSYCHIATRY, 2016, 16
  • [23] Validity and reliability of the triage scale in older people in a regional emergency department in Hong Kong
    Cheung, Kai Yeung
    Leung, Ling Pong
    HONG KONG JOURNAL OF EMERGENCY MEDICINE, 2021, 28 (02) : 65 - 71
  • [24] Validity and reliability of a novel Color-Risk Psychiatric Triage in a psychiatric emergency department
    Alejandro Molina-López
    Jeremy Bernardo Cruz-Islas
    Mauricio Palma-Cortés
    Diana Patricia Guizar-Sánchez
    César Yehú Garfias-Rau
    Martha Patricia Ontiveros-Uribe
    Ana Fresán-Orellana
    BMC Psychiatry, 16
  • [25] Predictive validity of the Triage Risk Screening Tool for elderly patients in a Canadian emergency department
    Fan, Jerome
    Worster, Andrew
    Fernandes, Christopher M. B.
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2006, 24 (05): : 540 - 544
  • [26] Validity of the Manchester triage system in the prioritization of patients with transient global amnesia in the emergency department
    Zaboli, Arian
    Turcato, Gianni
    Nucera, Bruna
    Sibilio, Serena
    Rinaldi, Fabrizio
    D'Acunto, Laura
    Manganotti, Paolo
    Nardone, Raffaele
    Pfeifer, Norbert
    Brigo, Francesco
    NEUROLOGY AND CLINICAL NEUROSCIENCE, 2023, 11 (05): : 262 - 267
  • [27] Predictive validity of the Manchester Triage System: evaluation of outcomes of patients admitted to an emergency department
    Pinto Junior, Domingos
    Salgado, Patricia de Oliveira
    Machado Chianca, Tania Couto
    REVISTA LATINO-AMERICANA DE ENFERMAGEM, 2012, 20 (06): : 1041 - 1047
  • [28] The Validity of the Pediatric Assessment Triangle as the First Step in the Triage Process in a Pediatric Emergency Department
    Fernandez, Ana
    Isabel Ares, Maria
    Garcia, Sara
    Martinez-Indart, Lorea
    Mintegi, Santiago
    Benito, Javier
    PEDIATRIC EMERGENCY CARE, 2017, 33 (04) : 234 - 238
  • [29] Severely increased blood pressure in the emergency department
    Shayne, PH
    Pitts, SR
    ANNALS OF EMERGENCY MEDICINE, 2003, 41 (04) : 513 - 529
  • [30] Epidemiology of Elevated Blood Pressure in Emergency Department
    Adhikari, S.
    Shostrom, V
    Carson, R.
    ANNALS OF EMERGENCY MEDICINE, 2009, 54 (03) : S55 - S56