Monte Carlo calculation of shielded colpostat effect on rectum received dose in high dose rate brachytherapy with Cobalt-60 sources

被引:0
|
作者
Mesbahi, A. [1 ,3 ]
Haghzadeh, A. [2 ]
Naseri, A. R. [3 ]
Shirazi, A. R. [2 ]
机构
[1] Tabriz Univ Med Sci, Sch Med, Dept Med Phys, Tabriz, Iran
[2] Azad Univ, Fac Engn, Sci & Res Branch, Med Radiat Engn Dept, Tehran, Iran
[3] Imam Hosp, Dept Radiat Oncol, Tabriz, Iran
来源
关键词
Intracavitary brachytherapy; shielded colpostat; rectum dose; high dose rate brachytherpy; cobalt-60; APPLICATOR; RADIOTHERAPY;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: In the current study the effect of shielded colpostat on rectum received dose was calculated in cervical brachytherapy using Monte Carlo (MC) method. Materials and Methods: Two Co-60 sources of GZP6 brachytherapy unit used for intracavitary treatments were simulated using MCNPX Monte Carlo code. Also the two types of colpostats including shielded and unshielded were simulated inside a water phantom. The radial dose function, depth doses and dose distribution around sources were calculated with spatial dose resolution of 2x2x2 mm. The effect of tungsten shields on rectum dose was studied. Moreover, the accuracy of treatment planning system (TPS) was verified comparing to MC results. Results: Our results showed that shielded colpostats reduce the rectum dose up to 7% according to the MC calculations. Also, it was found less than 3% difference between TPS and MC results in percentage depth dose and radial doses for unshielded case. Conclusion: It can be concluded that the application of shielded colpostats provide a relatively mild protection (7% reduction in dose) for the rectum in intracavitary brachytherapy due to the higher energy of Co-60 photons. However, application of shielded colpostats in treatment planning system is desirable for more accurate treatments.
引用
收藏
页码:165 / 171
页数:7
相关论文
共 50 条
  • [21] Dosimetric characterisation of the optically-stimulated luminescence dosimeter in cobalt-60 high dose rate brachytherapy system
    M. Rejab
    J. H. D. Wong
    Z. Jamalludin
    W. L. Jong
    R. A. Malik
    W. Z. Wan Ishak
    N. M. Ung
    Australasian Physical & Engineering Sciences in Medicine, 2018, 41 : 475 - 485
  • [22] Independent assessment of source transit time for the BEBIG SagiNova® cobalt-60 high dose rate brachytherapy afterloader
    Abolfazl Kanani
    Sareh Karbasi
    Mohammad Amin Mosleh-Shirazi
    Australasian Physical & Engineering Sciences in Medicine, 2019, 42 : 913 - 919
  • [23] Independent assessment of source transit time for the BEBIG SagiNova® cobalt-60 high dose rate brachytherapy afterloader
    Kanani, Abolfazl
    Karbasi, Sareh
    Mosleh-Shirazi, Mohammad Amin
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2019, 42 (04) : 913 - 919
  • [24] Design and manufacturing of a phantom for quality control of high dose rate Cobalt-60 source used in gynecologic brachytherapy
    Malekie, Shahryar
    Rajabi, Ali
    Rezaeian, Peiman
    Mohammadi, Seyed Mostafa
    Tajudin, Suffian Mohamad
    RADIATION PHYSICS AND CHEMISTRY, 2024, 224
  • [25] A Monte Carlo investigation of the dose distribution for 60Co high dose rate brachytherapy source in water and in different media
    Badry, Hamza
    Oufni, Lhoucine
    Ouabi, Hmad
    Hirayama, Hideo
    APPLIED RADIATION AND ISOTOPES, 2018, 136 : 104 - 110
  • [26] Development of An Ultra-Fast Monte Carlo Dose Engine for High Dose Rate Brachytherapy
    Tian, Z.
    Zhang, M.
    Hrycushko, B.
    Stojadinovic, S.
    Jiang, S.
    Jia, X.
    MEDICAL PHYSICS, 2014, 41 (06) : 488 - +
  • [27] Sub-second high dose rate brachytherapy Monte Carlo dose calculations with bGPUMCD
    Hissoiny, Sami
    D'Amours, Michel
    Ozell, Benoit
    Despres, Philippe
    Beaulieu, Luc
    MEDICAL PHYSICS, 2012, 39 (07) : 4559 - 4567
  • [28] HIGH DOSE RATE BRACHYTHERAPY: IN VIVO DOSIMETRY OF RADIATION DOSE TO THE RECTUM
    Ullen, A.
    Gorzov, P.
    Nilsson, J.
    Holmberg, C.
    Lundell, M.
    Kalkner, K. M.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S379 - S379
  • [29] Monte Carlo Evaluation for the Effect of Positional Inaccuracy of Source on Patient's Dose in High-Dose-Rate Brachytherapy
    Lee, Kyung Ja
    An, So Hyun
    Lee, Rena
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2009, 55 (06) : 2361 - 2365
  • [30] A general Monte Carlo dose calculation tool for intravascular brachytherapy
    Chibani, O
    Li, AX
    MEDICAL PHYSICS, 2002, 29 (06) : 1318 - 1318