Evaluation of optical radiation detectors in the range from 0.8 μm to 20 μm at the NIST infrared spectral calibration facility

被引:3
|
作者
Podobedov, Vyacheslav B. [1 ]
Eppeldauer, George P. [1 ]
Larason, Thomas C. [1 ]
机构
[1] NIST, Gaithersburg, MD 20899 USA
来源
OPTICAL SYSTEMS DESIGN 2012 | 2012年 / 8550卷
关键词
Detector; IR; irradiance; calibration; spectral responsivity; radiant power; radiometry;
D O I
10.1117/12.980937
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Analysis of multiple factors affecting the uncertainty of the absolute spectral responsivity of optical radiation detectors is presented. This includes both the validation of the radiometric scale of the infrared reference detectors and the scale transfer process to the unit under test. Reference detectors include a low NEP pyroelectric detector, an InSb detector, and a sphere-input extended InGaAs detector. While all three types of reference detectors were calibrated independently, less than 0.5 % mismatch of spectral responsivities was observed in the spectrally overlapping regions. We provide a performance evaluation of the NIST IR Detector Calibration Facility, which was designed for testing optical radiation detectors in both radiant power and irradiance measurement modes. This facility utilizes a high throughput monochromator with interchangeable diffraction gratings. Depending on the spectral range, a blackbody at 1100 degrees C, or a quartz halogen lamp with about a 10(-4) long-term relative output variation was used as a radiation source. In order to minimize the uncertainty budget for calibration data, specific attention was given to the profile of the incident beam, the precise positioning of detectors, and the influence of atmospheric absorption. In addition to the spectral responsivity calibration of detectors, the facility allows precise mapping of detector active area for spatial non-uniformity of response. Typical calibration uncertainties that can be achieved are about 1 % and 2.5 % (k=2) in the radiant power and irradiance modes, respectively. Examples for responsivity calibrations of different detectors are presented.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Monochromatic Radiation Source Based on a Supercontinuum Laser for Measurement of Spectral Sensitivity of Radiation Detectors in the Range 0.9-1.6 μm with the Use of an Absolute Cryogenic Radiometer
    Dunaev, A. Yu
    Baturin, A. S.
    Krutikov, V. N.
    Morozova, S. P.
    MEASUREMENT TECHNIQUES, 2021, 63 (11) : 877 - 882
  • [22] Absolute calibration of X-ray semiconductor detectors against synchrotron radiation from VEPP-2M storage ring in the photon energy range from 0.3 to 1.6 keV
    Gaganov, V.V.
    Kuper, K.E.
    Nikolenko, A.D.
    Pindyurin, V.F.
    Subbotin, A.N.
    Poverkhnost Rentgenovskie Sinkhronnye i Nejtronnye Issledovaniya, 2002, (09): : 36 - 40
  • [23] Absolute calibration of X-ray semiconductor detectors in the 0.3-1.5 keV photon energy range on synchrotron radiation from VEPP-2M storage ring
    Subbotin, AN
    Chernov, VA
    Gaganov, VV
    Kalutsky, AV
    Kovalenko, NV
    Krasnov, AK
    Kuper, KE
    Legkodymov, AG
    Nikolenko, AD
    Nesterenko, IN
    Pindyurin, VF
    Romaev, VN
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 470 (1-2): : 452 - 458
  • [24] Porcine skin damage threshold from mid-infrared optical parametric oscillator radiation at 3.743 μm
    Jiao, Luguang
    Wang, Chao
    Zhang, Kaizeng
    Wang, Jiarui
    Yang, Zaifu
    BIOMEDICAL OPTICS EXPRESS, 2020, 11 (12) : 7165 - 7174
  • [25] MULTIPURPOSE EFFICIENT TUNABLE INFRARED COHERENT SOURCE WITH TUNING RANGE FROM 0.8 TO 25 MU-M AND PEAK POWERS IN THE RANGE 50-200 KW
    KUPECEK, P
    LEPERSON, H
    COMTE, M
    INFRARED PHYSICS, 1979, 19 (3-4): : 263 - 271
  • [26] Spectral calibration of K-M giants from medium-resolution near-infrared HK-band spectra
    Ghosh, Supriyo
    Mondal, Soumen
    Das, Ramkrishna
    Khata, Dhrimadri
    MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 2019, 484 (04) : 4619 - 4634
  • [27] REGISTRATION OF OWN THERMAL-RADIATION OF THE ORBIT STATION MIR BY GROUND INFRARED TELESCOPE IN SPECTRAL RANGE 8-12 MU-M
    GRISHIN, EA
    MILOVIDOV, VL
    SHARGORODSKII, VD
    DOKLADY AKADEMII NAUK, 1995, 342 (03) : 338 - 341
  • [28] Spectral-energy characteristics of the daytime radiation of the earth in the 1.7-3.0-mu m range from Salyut orbital stations
    Malkina, TV
    Faraonova, VA
    Filippov, PI
    Gubarev, AA
    JOURNAL OF OPTICAL TECHNOLOGY, 1997, 64 (10) : 923 - 928
  • [29] Precision Glass Molding - Cost efficient production of glass optics with spectral range from 180 nm ultraviolet to 13 μm thermal infrared
    Staasmeyer, Jan-Helge
    Kreilkamp, Holger
    Dambon, Olaf
    Klocke, Fritz
    THIRD EUROPEAN SEMINAR ON PRECISION OPTICS MANUFACTURING, 2016, 10009
  • [30] Light emitting diodes for the spectral range λ=3.3–4.3 µm fabricated from InGaAs and InAsSbP solid solutions: Electroluminescence in the temperature range of 20–180°C (Part 2)
    M. Aidaraliev
    N. V. Zotova
    S. A. Karandashev
    B. A. Matveev
    M. A. Remennyi
    N. M. Stus’
    G. N. Talalakin
    Semiconductors, 2001, 35 : 598 - 604