Evaluation of optical radiation detectors in the range from 0.8 μm to 20 μm at the NIST infrared spectral calibration facility

被引:3
|
作者
Podobedov, Vyacheslav B. [1 ]
Eppeldauer, George P. [1 ]
Larason, Thomas C. [1 ]
机构
[1] NIST, Gaithersburg, MD 20899 USA
来源
OPTICAL SYSTEMS DESIGN 2012 | 2012年 / 8550卷
关键词
Detector; IR; irradiance; calibration; spectral responsivity; radiant power; radiometry;
D O I
10.1117/12.980937
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Analysis of multiple factors affecting the uncertainty of the absolute spectral responsivity of optical radiation detectors is presented. This includes both the validation of the radiometric scale of the infrared reference detectors and the scale transfer process to the unit under test. Reference detectors include a low NEP pyroelectric detector, an InSb detector, and a sphere-input extended InGaAs detector. While all three types of reference detectors were calibrated independently, less than 0.5 % mismatch of spectral responsivities was observed in the spectrally overlapping regions. We provide a performance evaluation of the NIST IR Detector Calibration Facility, which was designed for testing optical radiation detectors in both radiant power and irradiance measurement modes. This facility utilizes a high throughput monochromator with interchangeable diffraction gratings. Depending on the spectral range, a blackbody at 1100 degrees C, or a quartz halogen lamp with about a 10(-4) long-term relative output variation was used as a radiation source. In order to minimize the uncertainty budget for calibration data, specific attention was given to the profile of the incident beam, the precise positioning of detectors, and the influence of atmospheric absorption. In addition to the spectral responsivity calibration of detectors, the facility allows precise mapping of detector active area for spatial non-uniformity of response. Typical calibration uncertainties that can be achieved are about 1 % and 2.5 % (k=2) in the radiant power and irradiance modes, respectively. Examples for responsivity calibrations of different detectors are presented.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Calibration of spectral responsivity of IR detectors in the range from 0.6 μm to 24 μm
    Podobedov, Vyacheslav B.
    Eppeldauer, George P.
    Hanssen, Leonard M.
    Larason, Thomas C.
    INFRARED TECHNOLOGY AND APPLICATIONS XLII, 2016, 9819
  • [2] Radiation tolerance analysis of IASI infrared detectors in the 3.4-15.5 μm spectral range
    Bernard, Frederic
    Geoffraya, Herve
    Rolland, Guy
    Gilarda, O.
    Blumstein, D.
    Coppens, D.
    Cayla, F.
    SENSORS, SYSTEMS, AND NEXT-GENERATION SATELLITES XI, 2007, 6744
  • [3] IR-detectors from 0.9 μm to 13 μm spectral range at AIM
    Haiml, M.
    Bruder, M.
    Eich, D.
    Finck, M.
    Lutz, H.
    Simon, Th.
    Wendler, J.
    Wollrab, R.
    Ziegler, J.
    INFRARED TECHNOLOGY AND APPLICATIONS XXXIII, 2007, 6542
  • [4] Development of a monochromatic, uniform source facility for calibration of radiance and irradiance detectors from 0.2 μm to 12 μm
    Lykke, KR
    Shaw, PS
    Hanssen, LM
    Eppeldauer, GP
    METROLOGIA, 1999, 36 (02) : 141 - 146
  • [5] Development of a monochromatic, uniform source facility for calibration of radiance and irradiance detectors from 0.2 μm to 12 μm
    Lykke, KR
    Shaw, PS
    Hanssen, LM
    Eppeldauer, GP
    METROLOGIA, 1998, 35 (04) : 479 - 483
  • [6] Quaternary nonlinear optical crystals for the mid-infrared spectral range from 5 to 12 μm
    Petrov, V.
    Badikov, V.
    Panyutin, V.
    MID-INFRARED COHERENT SOURCES AND APPLICATIONS, 2008, : 105 - +
  • [7] Uncooled Photodiodes for Detecting Pulsed Infrared Radiation in the Spectral Range of 0.9–1.8 μm
    E. V. Kunitsyna
    A. A. Pivovarova
    I. A. Andreev
    G. G. Konovalov
    E. V. Ivanov
    N. D. Il’inskaya
    Yu. P. Yakovlev
    Semiconductors, 2021, 55 : 601 - 607
  • [8] Uncooled Photodiodes for Detecting Pulsed Infrared Radiation in the Spectral Range of 0.9-1.8 μm
    Kunitsyna, E., V
    Pivovarova, A. A.
    Andreev, I. A.
    Konovalov, G. G.
    Ivanov, E., V
    Il'inskaya, N. D.
    Yakovlev, Yu P.
    SEMICONDUCTORS, 2021, 55 (07) : 601 - 607
  • [9] Dispersion measurement in optical fibres over the entire spectral range from 1.1 μm to 1.7 μm
    Koch, F
    Chernikov, SV
    Taylor, JR
    OPTICS COMMUNICATIONS, 2000, 175 (1-3) : 209 - 213
  • [10] Group delay dispersion measurements in the mid-infrared spectral range of 2-20 μm
    Habel, Florian
    Trubetskov, Michael
    Pervak, Vladimir
    OPTICS EXPRESS, 2016, 24 (15): : 16705 - 16710