Telecine calibration and image quality evaluation

被引:0
|
作者
Lukicic, T [1 ]
Grgic, S [1 ]
机构
[1] Croatian Radio Televis, Zagreb 10000, Croatia
来源
关键词
telecine; TAF; video signal measurement;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
In this paper video signal level of the filmed material is measured on telecine with respect to a TAF (Telecine Analysis Film) as reference value. On telecine calibrated according to TAF, projection of filmed material from shooting location need same corrections. Instead of correcting signal, telecine is recalibrated according to the light conditions on shooting location and projects best possible image quality from shooting location. After the transfer, TAF is relaced and created video signal is measured. Results of measurement are compared and differences are established. Differences appear because of different light conditions, deliberately created to achieve artistic atmosphere of the picture, but must be unchanged during the same film scene in order to maintain constant quality level of the particular film part. Monitoring quality of filmed material is possible by control over established differences while transferring material from the same shooting location of the particular film scene. Uniformity of picture parameters during the whole film scene are considered as quality of shot material.
引用
收藏
页码:77 / 81
页数:5
相关论文
共 50 条
  • [21] Clinical image evaluation methods for calibration and QC
    Stone, T
    PHYSICS OF MEDICAL IMAGING: MEDICAL IMAGING 1996, 1996, 2708 : 564 - 573
  • [22] RADARSAT-2 Image Quality and Calibration Update
    Williams, Dan
    LeDantec, Pierre
    Chabot, Marielle
    Hillman, Anthony
    James, Kenny
    Caves, Ron
    Thompson, Alan
    Vigneron, Cathy
    Wu, Yan
    10TH EUROPEAN CONFERENCE ON SYNTHETIC APERTURE RADAR (EUSAR 2014), 2014,
  • [23] Quality assessment of radiometric calibration of UAV image mosaics
    Bagnall, Cody
    Thomasson, J. Alex
    Sima, Chao
    Yang, Chenghai
    AUTONOMOUS AIR AND GROUND SENSING SYSTEMS FOR AGRICULTURAL OPTIMIZATION AND PHENOTYPING III, 2018, 10664
  • [24] RADARSAT image quality and calibration performance-update
    Srivastava, SK
    Banik, BT
    Adamovic, M
    Hawkins, RK
    Lukowski, TI
    Murnaghan, KP
    Jefferies, WC
    IGARSS '98 - 1998 INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, PROCEEDINGS VOLS 1-5: SENSING AND MANAGING THE ENVIRONMENT, 1998, : 2454 - 2458
  • [25] THE QUALITATIVE EVALUATION OF IMAGE QUALITY AND DEFINITION OF AN IMAGE
    CHUDACEK, I
    JOURNAL OF INFORMATION RECORDING MATERIALS, 1988, 16 (06): : 453 - 466
  • [26] IMAGE QUALITY EVALUATION ASPECTS
    VYGON, VG
    LOGINOV, VV
    SOVIET JOURNAL OF OPTICAL TECHNOLOGY, 1985, 52 (04): : 203 - 205
  • [27] EVALUATION OF RADIOGRAPHIC IMAGE QUALITY
    ROSSMANN, K
    WILLIAMS, JR
    GOODENOUGH, DJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1973, 18 (04): : 594 - 594
  • [28] AN EVALUATION OF IMAGE QUALITY METRICS
    JACOBSON, RE
    JOURNAL OF PHOTOGRAPHIC SCIENCE, 1995, 43 (01): : 7 - 16
  • [29] Ultrasound image quality evaluation
    Loizou, C
    Pattichis, CS
    Istepanian, R
    Pantziaris, M
    Kyriakou, E
    Tyllis, T
    Nicolaides, A
    ITAB 2003: 4TH INTERNATIONAL IEEE EMBS SPECIAL TOPIC CONFERENCE ON INFORMATION TECHNOLOGY APPLICATIONS IN BIOMEDICINE, CONFERENCE PROCEEDINGS: NEW SOLUTIONS FOR NEW CHALLENGES, 2003, : 138 - 141
  • [30] EVALUATION OF RADIOGRAPHIC IMAGE QUALITY
    DEBEN, HS
    PHOTOGRAPHIC SCIENCE AND ENGINEERING, 1962, 6 (02): : 119 - 119