Reengineering Electronic Fetal Monitoring Interpretation: Using the Fetal Reserve Index to Anticipate the Need for Emergent Operative Delivery

被引:19
|
作者
Eden, Robert D. [1 ]
Evans, Mark I. [1 ,2 ,3 ]
Evans, Shara M. [1 ]
Schifrin, Barry S. [1 ]
机构
[1] Fetal Med Fdn Amer, New York, NY USA
[2] Comprehens Genet PLLC, 131 E 65th St, New York, NY 10065 USA
[3] Mt Sinai Sch Med, Dept Obstet & Gynecol, New York, NY USA
关键词
emergency operative deliveries; stat cesarean delivery; electronic fetal monitoring; fetal reserve index; ACOG monitoring classification system; intrauterine resuscitation; HEART-RATE; LABOR DYSTOCIA; WOMEN; PATTERNS; PROGRAM;
D O I
10.1177/1933719117737849
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: The near-ubiquitous use of electronic fetal monitoring has failed to lower the rates of both cerebral palsy and emergency operative deliveries (EODs). Its performance metrics have low sensitivity, specificity, and predictive values for both. There are many EODs, but the vast majority have normal outcomes. The EODs, however, cause serious disruption in the delivery suite routine with increased complications, anxiety, and concern for all. Methods: We developed the fetal reserve index (FRI) as multicomponent algorithm including 4 FHR components (analyzed individually), uterine activity, and maternal, obstetrical, and fetal risk factors to assess risk of cerebral palsy and EOD. Scores were categorized into green, yellow, and red zones. Here, we studied 300 patients by the FRI, all of whom had normal neonatal outcomes. We attempted to distinguish the clinical course of those cases which required an EOD versus controls which did not. Results: 51 cases with EOD had FRIs much lower than 249 non-EOD cases. The red zone was reached more frequently (P < .001) and lasted longer (1.06 vs 0.05 hours; P < .001). Reaching the red zone had a sensitivity of 92% for EOD, with a positive predictive value of 64% and a false positive rate of 10.4%. Conclusions: Our data suggest the FRI can significantly lower the incidence of EODs by identifying the opportunity for intrauterine resuscitation. Our approach can reduce the disruptive effects of EODs and their concomitant increased risks of complications. The FRI may provide a metric that can refine labor management to reduce CP and EODs.
引用
收藏
页码:487 / 497
页数:11
相关论文
共 50 条
  • [41] A comparison of maternal and fetal complications during operative vaginal delivery using Thierry's spatulas and the vacuum extractor
    Vanlieferinghen, S.
    Girard, G.
    Mandelbrot, L.
    JOURNAL DE GYNECOLOGIE OBSTETRIQUE ET BIOLOGIE DE LA REPRODUCTION, 2009, 38 (08): : 648 - 654
  • [42] ELECTRONIC FETAL MONITORING IN RELATION TO CESAREAN-SECTION DELIVERY, FOR LIVE BIRTHS AND STILLBIRTHS IN THE UNITED-STATES, 1980
    PLACEK, PJ
    KEPPEL, KG
    TAFFEL, SM
    LISS, TL
    PUBLIC HEALTH REPORTS, 1984, 99 (02) : 173 - 183
  • [43] Intrapartum fetal heart rate monitoring: evaluation of a standardized system of interpretation for prediction of metabolic acidosis at delivery and neonatal neurological morbidity
    Soncini, Emanuele
    Paganelli, Simone
    Vezzani, Cristina
    Gargano, Giancarlo
    Battista, La Sala Giovanni
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2014, 27 (14): : 1465 - 1469
  • [44] Further concerns about the National Institute of Child Health and Human Development guidelines for interpretation of electronic fetal heart rate monitoring
    Bernardes, J
    Ayres-de-Campos, D
    Costa-Pereira, A
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2001, 184 (07) : 1587 - 1588
  • [45] A pilot study using intra-partum ultrasound to aid in the definition of the position of the fetal head before operative delivery
    Udayasankar, V.
    Rajesh, U.
    Moselhi, M.
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2007, 27 (06) : 568 - 570
  • [46] The 2008 National Institute of Child Health and Human Development workshop report on electronic fetal monitoring: Update on definitions, interpretation, and research guidelines
    Macones, George A.
    Hankins, Gary D. V.
    Spong, Catherine Y.
    Hauth, John
    Moore, Thomas
    JOGNN-JOURNAL OF OBSTETRIC GYNECOLOGIC AND NEONATAL NURSING, 2008, 37 (05): : 510 - 515
  • [47] Further concerns about the National Institute of Child Health and Human Development guidelines for interpretation of electronic fetal heart rate monitoring - Reply
    Devoe, LD
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2001, 184 (07) : 1588 - 1588
  • [48] The 2008 National Institute of Child Health and Human Development Workshop Report on Electronic Fetal Monitoring: Update on Definitions, Interpretation, and Research Guidelines
    Ross, Michael G.
    OBSTETRICS AND GYNECOLOGY, 2009, 113 (01): : 230 - 230
  • [49] The 2008 National Institute of Child Health and Human Development workshop report on electronic fetal monitoring - Update on definitions, interpretation, and research guidelines
    Macones, George A.
    Hankins, Gary D. V.
    Spong, Catherine Y.
    Hauth, John
    Moore, Thomas
    OBSTETRICS AND GYNECOLOGY, 2008, 112 (03): : 661 - 666
  • [50] The effect of continuous electronic fetal monitoring on mode of delivery and neonatal outcome among low-risk laboring mothers at Debre Markos comprehensive specialized hospital, Northwest Ethiopia
    Kebede, Tirusew Nigussie
    Abebe, Kidist Ayalew
    Chekol, Moges Sisay
    Kitaw, Tebabere Moltot
    Mihret, Muhabaw Shumye
    Fentie, Bezawit Melak
    Sibhat, Yared Alem
    Tizazu, Michael Amera
    Beshah, Solomon Hailemeskel
    Taye, Birhan Tsegaw
    FRONTIERS IN GLOBAL WOMENS HEALTH, 2024, 5