Reengineering Electronic Fetal Monitoring Interpretation: Using the Fetal Reserve Index to Anticipate the Need for Emergent Operative Delivery

被引:19
|
作者
Eden, Robert D. [1 ]
Evans, Mark I. [1 ,2 ,3 ]
Evans, Shara M. [1 ]
Schifrin, Barry S. [1 ]
机构
[1] Fetal Med Fdn Amer, New York, NY USA
[2] Comprehens Genet PLLC, 131 E 65th St, New York, NY 10065 USA
[3] Mt Sinai Sch Med, Dept Obstet & Gynecol, New York, NY USA
关键词
emergency operative deliveries; stat cesarean delivery; electronic fetal monitoring; fetal reserve index; ACOG monitoring classification system; intrauterine resuscitation; HEART-RATE; LABOR DYSTOCIA; WOMEN; PATTERNS; PROGRAM;
D O I
10.1177/1933719117737849
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: The near-ubiquitous use of electronic fetal monitoring has failed to lower the rates of both cerebral palsy and emergency operative deliveries (EODs). Its performance metrics have low sensitivity, specificity, and predictive values for both. There are many EODs, but the vast majority have normal outcomes. The EODs, however, cause serious disruption in the delivery suite routine with increased complications, anxiety, and concern for all. Methods: We developed the fetal reserve index (FRI) as multicomponent algorithm including 4 FHR components (analyzed individually), uterine activity, and maternal, obstetrical, and fetal risk factors to assess risk of cerebral palsy and EOD. Scores were categorized into green, yellow, and red zones. Here, we studied 300 patients by the FRI, all of whom had normal neonatal outcomes. We attempted to distinguish the clinical course of those cases which required an EOD versus controls which did not. Results: 51 cases with EOD had FRIs much lower than 249 non-EOD cases. The red zone was reached more frequently (P < .001) and lasted longer (1.06 vs 0.05 hours; P < .001). Reaching the red zone had a sensitivity of 92% for EOD, with a positive predictive value of 64% and a false positive rate of 10.4%. Conclusions: Our data suggest the FRI can significantly lower the incidence of EODs by identifying the opportunity for intrauterine resuscitation. Our approach can reduce the disruptive effects of EODs and their concomitant increased risks of complications. The FRI may provide a metric that can refine labor management to reduce CP and EODs.
引用
收藏
页码:487 / 497
页数:11
相关论文
共 50 条
  • [31] Diminishing Fetal Reserve is Quantifiable in Labor: Contextualized Interpretation Using Mom's Statistics.
    Evans, Mark I.
    Britt, David W.
    Eden, Robert D.
    Evans, Shara M.
    Gallagher, Paula
    Schifrin, Barry S.
    REPRODUCTIVE SCIENCES, 2020, 27 (SUPPL 1) : 305A - 305A
  • [32] Some concerns about the new research guidelines for interpretation of electronic fetal heart rate monitoring - Reply
    Parer, JT
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1998, 179 (02) : 560 - 561
  • [33] Interobserver agreement in CTG interpretation using the 2015 FIGO guidelines for intrapartum fetal monitoring
    Rei, Mariana
    Tavares, Sara
    Pinto, Pedro
    Machado, Ana P.
    Monteiro, Sofia
    Costa, Antonia
    Costa-Santos, Cristina
    Bernardes, Joao
    Ayres-De-Campos, Diogo
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2016, 205 : 27 - 31
  • [34] Multidisciplinary teamwork approach in labor and delivery and electronic fetal monitoring education - A medical-legal perspective
    Collins, Dawn E.
    JOURNAL OF PERINATAL & NEONATAL NURSING, 2008, 22 (02) : 125 - 132
  • [35] Monitoring intrahepatic cholestasis of pregnancy using the fetal myocardial performance index: a cohort study
    Henry, A.
    Welsh, A. W.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2015, 46 (05) : 571 - 578
  • [36] Machine Learning Algorithm to Predict Acidemia Using Electronic Fetal Monitoring Recording Parameters
    Esteban-Escano, Javier
    Castan, Berta
    Castan, Sergio
    Choliz-Ezquerro, Marta
    Asensio, Cesar
    Laliena, Antonio R.
    Sanz-Enguita, Gerardo
    Sanz, Gerardo
    Esteban, Luis Mariano
    Saviron, Ricardo
    ENTROPY, 2022, 24 (01)
  • [37] The clinical interpretation and significance of electronic fetal heart rate patterns 2 h before delivery: an institutional observational study
    Maso, Gianpaolo
    Businelli, Caterina
    Piccoli, Monica
    Montico, Marcella
    De Seta, Francesco
    Sartore, Andrea
    Alberico, Salvatore
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2012, 286 (05) : 1153 - 1159
  • [38] The clinical interpretation and significance of electronic fetal heart rate patterns 2 h before delivery: an institutional observational study
    Gianpaolo Maso
    Caterina Businelli
    Monica Piccoli
    Marcella Montico
    Francesco De Seta
    Andrea Sartore
    Salvatore Alberico
    Archives of Gynecology and Obstetrics, 2012, 286 : 1153 - 1159
  • [39] Assessment of an Alternative Stabilization Device for Electronic Fetal Monitoring Utilizing External Ultrasound and Tocodynamometer in Labor and Delivery Patients
    Teplick, Frann
    JOGNN-JOURNAL OF OBSTETRIC GYNECOLOGIC AND NEONATAL NURSING, 2012, 41 : S140 - S140
  • [40] Re-engineering the interpretation of electronic fetal monitoring to identify reversible risk for cerebral palsy: a case control series
    Evans, Mark I.
    Eden, Robert D.
    Britt, David W.
    Evans, Shara M.
    Schifrin, Barry S.
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2019, 32 (15): : 2561 - 2569