Modeling Effective Dosages in Hormetic Dose-Response Studies

被引:61
|
作者
Belz, Regina G. [1 ]
Piepho, Hans-Peter [2 ]
机构
[1] Univ Hohenheim, Agroecol Unit, Inst Plant Prod & Agroecol Trop & Subtrop, D-7000 Stuttgart, Germany
[2] Univ Hohenheim, Inst Crop Sci, Bioinformat Unit, D-7000 Stuttgart, Germany
来源
PLOS ONE | 2012年 / 7卷 / 03期
关键词
PARTHENIUM-HYSTEROPHORUS L; PLANT-GROWTH; HORMESIS; ALLELOPATHY; STIMULATION;
D O I
10.1371/journal.pone.0033432
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Two hormetic modifications of a monotonically decreasing log-logistic dose-response function are most often used to model stimulatory effects of low dosages of a toxicant in plant biology. As just one of these empirical models is yet properly parameterized to allow inference about quantities of interest, this study contributes the parameterized functions for the second hormetic model and compares the estimates of effective dosages between both models based on 23 hormetic data sets. Based on this, the impact on effective dosage estimations was evaluated, especially in case of a substantially inferior fit by one of the two models. Methodology/Principal Findings: The data sets evaluated described the hormetic responses of four different test plant species exposed to 15 different chemical stressors in two different experimental dose-response test designs. Out of the 23 data sets, one could not be described by any of the two models, 14 could be better described by one of the two models, and eight could be equally described by both models. In cases of misspecification by any of the two models, the differences between effective dosages estimates (0-1768%) greatly exceeded the differences observed when both models provided a satisfactory fit (0-26%). This suggests that the conclusions drawn depending on the model used may diverge considerably when using an improper hormetic model especially regarding effective dosages quantifying hormesis. Conclusions/Significance: The study showed that hormetic dose responses can take on many shapes and that this diversity can not be captured by a single model without risking considerable misinterpretation. However, the two empirical models considered in this paper together provide a powerful means to model, prove, and now also to quantify a wide range of hormetic responses by reparameterization. Despite this, they should not be applied uncritically, but after statistical and graphical assessment of their adequacy.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] DOSE-RESPONSE AND IMMORTALITY IN SMR STUDIES
    BEAUMONT, JJ
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1980, 22 (09) : 574 - &
  • [32] Estimating the maximum effective dose in a quantitative dose-response experiment
    Remmenga, MD
    Milliken, GA
    Kratzer, D
    Schwenke, JR
    Rolka, HR
    JOURNAL OF ANIMAL SCIENCE, 1997, 75 (08) : 2174 - 2183
  • [33] Benchmark dose modeling for epidemiological dose-response assessment using case-control studies
    De Pretis, Francesco
    Zhou, Yun
    Shao, Kan
    RISK ANALYSIS, 2024,
  • [34] Two-Stage Experimental Design for Dose-Response Modeling in Toxicology Studies
    Wang, Kai
    Yang, Feng
    Porter, Dale W.
    Wu, Nianqiang
    ACS SUSTAINABLE CHEMISTRY & ENGINEERING, 2013, 1 (09): : 1119 - 1128
  • [35] On dose-response modeling for evaluation of drugs combinations
    Flournoy, Nancy
    Hearne, Leonard B.
    Kiselak, Jozef
    Stehlik, Milan
    STOCHASTIC ANALYSIS AND APPLICATIONS, 2024, 42 (01) : 45 - 63
  • [36] Dose-response modeling for developmental neurotoxicity data
    Razzaghi, M
    Kodell, R
    ENVIRONMENTAL AND ECOLOGICAL STATISTICS, 2000, 7 (02) : 191 - 203
  • [37] BAYESIAN HIERARCHICAL MODELING OF DOSE-RESPONSE CURVES
    MacLehose, R.
    Dunson, D.
    Richardson, D.
    AMERICAN JOURNAL OF EPIDEMIOLOGY, 2009, 169 : S127 - S127
  • [38] TK/TD dose-response modeling of toxicity
    Begum, Munni
    Sen, Pranab K.
    ENVIRONMETRICS, 2007, 18 (05) : 515 - 525
  • [39] A Bayesian Approach to Dose-Response Assessment and Synergy and Its Application to In Vitro Dose-Response Studies
    Hennessey, Violeta G.
    Rosner, Gary L.
    Bast, Robert C., Jr.
    Chen, Min-Yu
    BIOMETRICS, 2010, 66 (04) : 1275 - 1283
  • [40] STAGEWISE, ADAPTIVE DOSE ALLOCATION FOR QUANTAL RESPONSE DOSE-RESPONSE STUDIES
    FEDER, PI
    HOBSON, DW
    OLSON, CT
    JOINER, RL
    MATTHEWS, MC
    NEUROSCIENCE AND BIOBEHAVIORAL REVIEWS, 1991, 15 (01): : 109 - 114