Minimally invasive cortical bone trajectory screws placement via pedicle or pedicle rib unit in the lower thoracic spine: a cadaveric and radiographic study

被引:8
|
作者
Xuan, Jun [1 ]
Zhang, Di [1 ]
Jin, Hai-Ming [1 ]
Chen, Jiao-Xiang [1 ]
Xu, Dao-Liang [1 ]
Xu, Hong-Ming [2 ]
Wu, Yao-Sen [1 ]
Wang, Xiang-Yang [1 ]
机构
[1] Wenzhou Med Univ, Affiliated Hosp 2, Dept Orthopaed Surg, 109 Xueyuanxi Rd, Wenzhou 325027, Peoples R China
[2] Wenzhou Med Univ, Affiliated Cixi Hosp, Dept Orthopaed Surg, Ningbo 315300, Peoples R China
关键词
Minimally invasive; Cortical bone trajectory screws; Thoracic pedicle screws; Rescue failed screws; Pedicle rib unit; MORPHOMETRIC MEASUREMENT; TRANSPEDICULAR SCREWS; IDIOPATHIC SCOLIOSIS; MORPHOLOGY; FIXATION; CT;
D O I
10.1007/s00586-016-4730-y
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
To evaluate the feasibility of cortical bone trajectory (CBT) screws fixation via pedicle or pedicle rib unit in the cadaveric thoracic spine (T9-T12). Computed tomography (CT) images of 100 patients are analyzed by multiplanar reconstruction. Ten cadaveric thoracic spines are used to insert 4.5 x 35.0 mm CBT screws at all levels from T9 to T12. Maximal screw length obtained by CT has a tendency to gradually increase from T9 (29.64 mm) to T12 (32.84 mm), and the difference reaches significant level at all levels except T9 versus T10 (P < 0.01). Maximal screw diameter increases from T9 (4.92 mm) to T12 (7.47 mm) and the difference reaches significant level among all levels (P < 0.01). Lateral angle increases from T9 (7.37A degrees) to T12 (10.47A degrees), and the difference reaches significant level among all levels except T11 versus T12. Cephalad angle from T9 to T12 are 19.03A degrees, 22.10A degrees, 25.62A degrees and 27.50A degrees (P < 0.01), respectively. The percentage of the inner and outer pedicle breakage are 2.5 and 22.5 %, respectively. The violation of lateral pedicle wall occurs at T9 and T10, especially for women at T9. Both radiographic and cadaveric studies establish the feasibility of CBT screws placement via pedicle or pedicle rib unit in the lower thoracic spine (T9-T12). Furthermore, our measurements are also useful for application of this technique.
引用
收藏
页码:4199 / 4207
页数:9
相关论文
共 50 条
  • [41] Computed-tomography-based anatomical study to assess feasibility of pedicle screw placement in the lumbar and lower thoracic pediatric spine
    Shaikh, Kashif A.
    Bennett, Garrett M.
    White, Ian K.
    Bullis, Carli L.
    Fulkerson, Daniel H.
    CHILDS NERVOUS SYSTEM, 2012, 28 (10) : 1743 - 1754
  • [42] Computed-tomography-based anatomical study to assess feasibility of pedicle screw placement in the lumbar and lower thoracic pediatric spine
    Kashif A. Shaikh
    Garrett M. Bennett
    Ian K. White
    Carli L. Bullis
    Daniel H. Fulkerson
    Child's Nervous System, 2012, 28 : 1743 - 1754
  • [43] Regional Hounsfield unit measurement of screw trajectory for predicting pedicle screw fixation using cortical bone trajectory: a retrospective cohort study
    Keitaro Matsukawa
    Yuichiro Abe
    Yoshihide Yanai
    Yoshiyuki Yato
    Acta Neurochirurgica, 2018, 160 : 405 - 411
  • [44] Regional Hounsfield unit measurement of screw trajectory for predicting pedicle screw fixation using cortical bone trajectory: a retrospective cohort study
    Matsukawa, Keitaro
    Abe, Yuichiro
    Yanai, Yoshihide
    Yato, Yoshiyuki
    ACTA NEUROCHIRURGICA, 2018, 160 (02) : 405 - 411
  • [45] Comparative Study of Two Surgical Techniques for Proximal Adjacent Segment Pathology after Posterior Lumbar Interbody Fusion with Pedicle Screws: Fusion Extension using Conventional Pedicle Screw vs Cortical Bone Trajectory-Pedicle Screw (Cortical Screw)
    Lee, Gun Woo
    Shin, Ji-Hoon
    WORLD NEUROSURGERY, 2018, 117 : E154 - E161
  • [46] Minimally invasive lumbar pedicle screw fixation using cortical bone trajectory - Screw accuracy, complications, and learning curve in 100 screw placements
    Dayani, Fara
    Chen, Yi-Ren
    Johnson, Eli
    Deb, Sayantan
    Wu, Yunfen
    Lan Pham
    Singh, Harminder
    JOURNAL OF CLINICAL NEUROSCIENCE, 2019, 61 : 106 - 111
  • [47] Electromagnetic field-based image-guided spine surgery part two: Results of a cadaveric study evaluating thoracic pedicle screw placement
    Sagi, HC
    Manos, R
    Park, SC
    Von Jako, R
    Ordway, NR
    Connolly, PJ
    SPINE, 2003, 28 (17) : E351 - E354
  • [48] Comparing Cortical Bone Trajectory and Traditional Pedicle Screws in Transforaminal Lumbar Interbody Fusion: A Retrospective Cohort Study of One-Year Outcomes
    Gutierrez, Juanmarco
    Erwood, Andrew M.
    Malcolm, James G.
    Grogan, Dayton P.
    Greven, Alexander C.
    Gary, Matthew F.
    Rodts, Gerald E.
    Stricsek, Geoffrey P.
    Refai, Daniel
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (08)
  • [49] Robot guidance for percutaneous minimally invasive placement of pedicle screws for pyogenic spondylodiscitis is associated with lower rates of wound breakdown compared to conventional fluoroscopy-guided instrumentation
    Alaid, Awad
    von Eckardstein, Kajetan
    Smoll, Nicolas Roydon
    Solomiichuk, Volodymyr
    Rohde, Veit
    Martinez, Ramon
    Schatlo, Bawarjan
    NEUROSURGICAL REVIEW, 2018, 41 (02) : 489 - 496
  • [50] Robot guidance for percutaneous minimally invasive placement of pedicle screws for pyogenic spondylodiscitis is associated with lower rates of wound breakdown compared to conventional fluoroscopy-guided instrumentation
    Awad Alaid
    Kajetan von Eckardstein
    Nicolas Roydon Smoll
    Volodymyr Solomiichuk
    Veit Rohde
    Ramon Martinez
    Bawarjan Schatlo
    Neurosurgical Review, 2018, 41 : 489 - 496