Robot guidance for percutaneous minimally invasive placement of pedicle screws for pyogenic spondylodiscitis is associated with lower rates of wound breakdown compared to conventional fluoroscopy-guided instrumentation

被引:0
|
作者
Awad Alaid
Kajetan von Eckardstein
Nicolas Roydon Smoll
Volodymyr Solomiichuk
Veit Rohde
Ramon Martinez
Bawarjan Schatlo
机构
[1] University Medicine Göttingen Georg-August-University of Göttingen,Department of Neurosurgery
[2] University of Newcastle,School of Medicine and Public Health
[3] Berufsgenossenschaftliches Universitätsklinikum Bergmannsheil,Abteilung BG Neurochirurgie und Neurotraumatologie
来源
Neurosurgical Review | 2018年 / 41卷
关键词
Spine instrumentation; Spondylodiscitis; Robotic surgery; Spinal fusion; Methicillin-resistant ;
D O I
暂无
中图分类号
学科分类号
摘要
Postoperative wound healing can pose a problem in patients undergoing instrumented surgery for pyogenic spondylodiscitis. Robotic guidance allows the minimally invasive placement of pedicle screws in the thoracolumbar spine. We assessed whether using this technique to perform minimally invasive surgery had an impact on wound healing in patients with pyogenic spondylodiscitis when compared to conventional open fluoroscopy-guided surgery. We reviewed charts of 206 consecutive patients who underwent instrumentation for pyogenic spondylodiscitis. The need for wound revision was the primary outcome measure. Patient variables and comorbidities as well as surgical technique (robotic versus fluoroscopy-guided) were analyzed. We also compared fluoroscopy times between the two groups. Multivariate regression analysis was performed to identify predictors of wound breakdown. A total of 206 patients underwent surgery for spondylodiscitis. Robotic surgical assistance was used for percutaneous instrumentation in 47.6% of cases (n = 98). Wound healing problems requiring revision occurred in 30 out of 206 patients (14.6%). Univariate analysis revealed a potential association of wound breakdown with (1) robotic technique, (2) age > 70 years, and (3) the presence of methicillin-resistant Staphylococcus aureus. After multivariate correction however, only robotic technique retained significance with an odds ratio of 0.39 (CI 95% 0.16–0.94; p = 0.035). Wound revision was required in eight out of 98 patients (8.1%) in the robot group and 22/108 (20%) in the conventional surgery group. Fluoroscopy times were significantly lower in the robot group with a mean of 123 ± 86 s in comparison with a mean of 157 ± 99 s in the conventional group (p = 0.014). While initially designed to improve the accuracy of pedicle screw placement, robot-assisted minimally invasive technique had a tangible effect on both radiation exposure and the rate of wound breakdown in patients with pyogenic spondylodiscitis in our large single-center study.
引用
收藏
页码:489 / 496
页数:7
相关论文
共 5 条
  • [1] Robot guidance for percutaneous minimally invasive placement of pedicle screws for pyogenic spondylodiscitis is associated with lower rates of wound breakdown compared to conventional fluoroscopy-guided instrumentation
    Alaid, Awad
    von Eckardstein, Kajetan
    Smoll, Nicolas Roydon
    Solomiichuk, Volodymyr
    Rohde, Veit
    Martinez, Ramon
    Schatlo, Bawarjan
    NEUROSURGICAL REVIEW, 2018, 41 (02) : 489 - 496
  • [2] How accurate is fluoroscopy-guided percutaneous pedicle screw placement in minimally invasive TLIF?
    El-Desouky, Ashraf
    Silva, Pedro Santos
    Ferreira, Ana
    Wibawa, Gibran Aditiara
    Vaz, Rui
    Pereira, Paulo
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2021, 205
  • [3] Robot-Assisted Percutaneous Pedicle Screw Placement: Evaluation of Accuracy of the First 100 Screws and Comparison with Cohort of Fluoroscopy-guided Screws
    Fayed, Islam
    Tai, Alexander
    Triano, Matthew
    Sayah, Anousheh
    Makariou, Erini
    Voyadzis, Jean-Marc
    Sandhu, Faheem A.
    WORLD NEUROSURGERY, 2020, 143 : E492 - E502
  • [4] Positioning accuracy and facet joints violation after percutaneous pedicle screws placement with robot-assisted versus fluoroscopy-guided technique: Systematic review and meta-analysis
    Perna, Andrea
    Velluto, Calogero
    Smakaj, Amarildo
    Tamburrelli, Francesco
    Borruto, Maria Ilaria
    Santagada, Domenico Alessandro
    Gorgoglione, Franco Lucio
    Liuzza, Francesco
    Proietti, Luca
    JOURNAL OF NEUROSCIENCES IN RURAL PRACTICE, 2023, 14 (03) : 406 - 412
  • [5] Fluoroscopy time analysis of a prospective, multi-centre study comparing robotic- and fluoroscopic-guided placement of percutaneous pedicle screw instrumentation for short segment minimally invasive lumbar fusion surgery
    Jamshidi, Aria M.
    Massel, Dustin H.
    Liounakos, Jason I.
    Silman, Zmira
    Good, Christopher R.
    Schroerlucke, Samuel R.
    Cannestra, Andrew
    Hsu, Victor
    Lim, Jae
    Zahrawi, Faissal
    Ramirez, Pedro M.
    Sweeney, Thomas M.
    Wang, Michael Y.
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2021, 17 (02):