IBIS Mask pre-calibration matrix

被引:0
|
作者
Reglero, V [1 ]
Sánchez, F [1 ]
Rodrigo, J [1 ]
Velasco, T [1 ]
Gasent, JL [1 ]
Chato, R [1 ]
Alamo, J [1 ]
Burgos, JA [1 ]
Suso, J [1 ]
Blay, P [1 ]
Martínez, S [1 ]
Doñate, M [1 ]
Reina, M [1 ]
Sabau, D [1 ]
Ruiz-Urien, I [1 ]
Santos, I [1 ]
Zarauz, J [1 ]
机构
[1] Univ Politecn Valencia, ICMUV, GACE, E-46071 Valencia, Spain
来源
关键词
high energy astrophysics; imaging; signal multiplexing;
D O I
暂无
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
Coded Aperture System performances are defined by the geometry of the code, detector pixel geometry relationship and focal length. Physical Coded Aperture Systems deviate from the ideal ones on two basic aspects: uncertainties on pixel location and size coming form the manufacturing process and deviations from their theoretical transparency/opacity values (1/0, 0/1), when support structures are required. Mask support structure imposes penalties on transparency as a function of the energy and angle of the incident photons. Pixel position and size values include uncertainties coming from the code cut in tungsten plates and assembly process. The scope of this paper is to summarize the results of the code elements position and size, as well as transparency/opacity values found for the IBIS Coded Aperture System. Both sets of data define the optical performances of the IBIS Mask required to perform accurate imaging of celestial gamma-ray sources.
引用
收藏
页码:619 / 622
页数:4
相关论文
共 50 条
  • [41] Engine Model-Based Pre-calibration and Optimization for Mid-level Hierarchical Control Design
    Shamekhi, Amir-Mohammad
    Shamekhi, Amir H.
    SAE INTERNATIONAL JOURNAL OF ENGINES, 2021, 14 (05) : 651 - 669
  • [42] An algorithm for estimation and correction of anisotropic magnification distortion of cryo-EM images without need of pre-calibration
    Yu, Guimei
    Li, Kunpeng
    Liu, Yue
    Chen, Zhenguo
    Wang, Zhiqing
    Yan, Rui
    Klose, Thomas
    Tang, Liang
    Jiang, Wen
    JOURNAL OF STRUCTURAL BIOLOGY, 2016, 195 (02) : 207 - 215
  • [43] Analysis on Mapping Accuracy of a Drone Composite Sensor: Focusing on Pre-calibration According to the Circumstances of Data Acquisition Area
    Jeon, Ilseo
    Ham, Sangwoo
    Lee, Impyeong
    KOREAN JOURNAL OF REMOTE SENSING, 2021, 37 (03) : 577 - 589
  • [45] Improved Two-Probe Approach for In-Circuit Measurement Based on Three-Port Network Pre-Calibration
    Li, Xing-Ming
    Hu, Shan-Qing
    See, Kye-Yak
    Li, Kang-Rong
    2015 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (APEMC), 2015, : 60 - 63
  • [46] IBIS calibration unit on integral satellite
    Poulsen, JM
    Sarra, P
    Bird, AJ
    Quadrini, EM
    Ubertini, P
    Frutti, M
    Ronchi, R
    Colferai, A
    Di Cosimo, S
    EXPLORING THE GAMMA-RAY UNIVERSE, 2001, 459 : 615 - 618
  • [47] A Method for Pre-Calibration of DI Diesel Engine Emissions and Performance Using Neural Network and Multi-Objective Genetic Algorithm
    Samadani, Ehsan
    Shamekhi, Amir Hossein
    Behroozi, Mohammad Hassan
    Chini, Reza
    IRANIAN JOURNAL OF CHEMISTRY & CHEMICAL ENGINEERING-INTERNATIONAL ENGLISH EDITION, 2009, 28 (04): : 61 - 70
  • [48] In-flight performance of the IBIS calibration unit
    Bird, AJ
    Bazzano, A
    Ferguson, C
    La Rosa, G
    Malaguti, G
    Ubertini, P
    ASTRONOMY & ASTROPHYSICS, 2003, 411 (01) : L197 - L201
  • [49] In-flight performance of the IBIS calibration unit
    Bird, A.J. (ajb@astro.soton.ac.uk), 1600, EDP Sciences (411):
  • [50] A control rod worth prediction using Adaptive Neuro-Fuzzy Inference System for Pre-Calibration Method at TRIGA PUSPATI Reactor
    Hui, Teh Zhi
    Ali, Nur Syazwani Mohd
    Minhat, Mohd Sabri
    Zainal, Jasman
    Sazali, Muhammad Arif
    Sarkawi, Muhammad Syahir
    Jamaluddin, Khairulnadzmi
    Basri, Nor Afifah
    Sies, Mohsin Mohd
    Rashid, Nahrul Khair Alang Md
    ANNALS OF NUCLEAR ENERGY, 2024, 200