IBIS Mask pre-calibration matrix

被引:0
|
作者
Reglero, V [1 ]
Sánchez, F [1 ]
Rodrigo, J [1 ]
Velasco, T [1 ]
Gasent, JL [1 ]
Chato, R [1 ]
Alamo, J [1 ]
Burgos, JA [1 ]
Suso, J [1 ]
Blay, P [1 ]
Martínez, S [1 ]
Doñate, M [1 ]
Reina, M [1 ]
Sabau, D [1 ]
Ruiz-Urien, I [1 ]
Santos, I [1 ]
Zarauz, J [1 ]
机构
[1] Univ Politecn Valencia, ICMUV, GACE, E-46071 Valencia, Spain
来源
关键词
high energy astrophysics; imaging; signal multiplexing;
D O I
暂无
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
Coded Aperture System performances are defined by the geometry of the code, detector pixel geometry relationship and focal length. Physical Coded Aperture Systems deviate from the ideal ones on two basic aspects: uncertainties on pixel location and size coming form the manufacturing process and deviations from their theoretical transparency/opacity values (1/0, 0/1), when support structures are required. Mask support structure imposes penalties on transparency as a function of the energy and angle of the incident photons. Pixel position and size values include uncertainties coming from the code cut in tungsten plates and assembly process. The scope of this paper is to summarize the results of the code elements position and size, as well as transparency/opacity values found for the IBIS Coded Aperture System. Both sets of data define the optical performances of the IBIS Mask required to perform accurate imaging of celestial gamma-ray sources.
引用
收藏
页码:619 / 622
页数:4
相关论文
共 50 条
  • [21] ROBUST HIGH-RESOLUTION DOA ESTIMATION WITH ARRAY PRE-CALIBRATION
    Weiss, Christian
    Zoubir, Abdelhak M.
    2014 PROCEEDINGS OF THE 22ND EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO), 2014, : 1049 - 1052
  • [22] Design of pre-calibration method for concrete distributor based on photoelectric switch
    Li, Dong
    Li, Yang
    Zhang, Ke
    Wu, Yuhou
    Sun, Hong
    Zou, Defang
    PROCEEDINGS OF THE 38TH CHINESE CONTROL CONFERENCE (CCC), 2019, : 4282 - 4285
  • [23] The CMS electromagnetic calorimeter pre-calibration with cosmic rays and test beam electrons
    Ferri, F.
    Govoni, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 581 (1-2): : 377 - 379
  • [24] Imaging With the IBIS Mask
    J.A. Berná
    J.M. Torrejón
    G. Bernabeu
    Astrophysics and Space Science, 2001, 276 : 333 - 336
  • [25] Automated high-throughput electron tomography by pre-calibration of image shifts
    Ziese, U
    Janssen, AH
    Murk, JL
    Geerts, WJC
    Van der Krift, T
    Verkleij, AJ
    Koster, AJ
    JOURNAL OF MICROSCOPY, 2002, 205 (02) : 187 - 200
  • [26] Imaging with the IBIS mask
    Berná, JA
    Torrejón, JM
    Bernabeu, G
    ASTROPHYSICS AND SPACE SCIENCE, 2001, 276 (01) : 333 - 336
  • [27] A three-dimensional measurement method for colorful objects based on intensity pre-calibration
    Zhu, Qian
    Zhao, Hong
    Gong, Zixuan
    OPTICAL REVIEW, 2022, 29 (04) : 343 - 353
  • [28] A three-dimensional measurement method for colorful objects based on intensity pre-calibration
    Qian Zhu
    Hong Zhao
    Zixuan Gong
    Optical Review, 2022, 29 : 343 - 353
  • [29] Pre-calibration and compensation of quadrature components in continuous-variable quantum key distribution
    Jiajia Xiang
    Tao Wang
    Lang Li
    Yuehan Xu
    Peng Huang
    Guihua Zeng
    Quantum Information Processing, 22
  • [30] Passive Magnetic Localization Based on Connotative Pre-Calibration for Tongue-Machine-Interface
    Shen, Hui-Min
    Ge, Di
    Lian, Chong
    Yue, Yang
    IEEE ACCESS, 2020, 8 : 2382 - 2394