Application of common transformers faults diagnosis methods on biodegradable oil-filled transformers

被引:13
|
作者
Muhamad, N. A. [1 ]
Phung, B. T. [2 ]
Blackburn, T. R. [2 ]
机构
[1] Univ Technol Malaysia, Skudai, Johor, Malaysia
[2] Univ New S Wales, Kensington, NSW 2033, Australia
关键词
Oil-filled transformers; Biodegradable oil; Mineral oil; Transformer faults; Insulation diagnostics; Dissolved gas-in-oil analysis; Partial discharge;
D O I
10.1007/s00202-012-0232-z
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Due to environmental concerns regarding the use of mineral oil, biodegradable oil is increasingly being used as an alternative dielectric fluid. This paper presents results of experiments performed in the laboratory on the use of biodegradable oils for transformer application. The investigations cover two important diagnostic techniques for insulation assessment: (i) an investigation of partial discharge (PD) activity and characteristics in such oils and (ii) an investigation of the standard hydrocarbon dissolved gas products produced due to transformer faults. The fundamental aim of the investigation was to provide information as to whether the existing analysis techniques of PD fault pattern recognition and dissolved gas analysis methods, developed for mineral oil, are valid when used for insulation assessment with biodegradable transformer oil. The experiments were conducted on test samples to simulate three common types of transformer faults: low-energy PDs, high-energy arcing/sparking, and overheating. For the purpose of comparison, the same tests were performed using a mineral oil (Shell Diala MX) and a biodegradable oil (Envirotemp FR3). Also, each oil type was tested at three different moisture levels and with or without the presence of solid insulating materials (pressboard). PD activity was monitored using the standard IEC60270 phase-resolved analysis method. The fault gases produced were extracted and analysed by standard gas chromatography methods. Test results indicate that the PD phase resolved patterns are, in general, similar for the two oil types and thus existing PD pattern interpretations can be used to distinguish different types of PD faults, e.g. corona versus surface discharges. However, the values of various discharge quantities (PD magnitudes, repetition rate, current, etc) are very different under the same test condition. The quantities and the trend of dissolved gases for faults in biodegradable oil are substantially different compared with mineral oil. For the PD fault, biodegradable oil was found to release only a limited number of gases. For arcing and overheating faults, the main key gas produced is different between the two oils. Also, the presence of cellulosic materials such as pressboard influences the extent of hydrocarbon gases dissolved in the oil. It was found that for biodegradable oil, fewer amounts of gases are produced as the oil gets wetter.
引用
收藏
页码:207 / 216
页数:10
相关论文
共 50 条
  • [31] Comparative Analysis of the Results of Diagnostic Measurements with an Internal Inspection of Oil-Filled Power Transformers
    Piotrowski, Tomasz
    Rozga, Pawel
    Kozak, Ryszard
    ENERGIES, 2019, 12 (11)
  • [32] Temperature rise of small oil-filled distribution transformers supplying nonsinusoidal load currents
    Galli, AW
    Cox, MD
    IEEE TRANSACTIONS ON POWER DELIVERY, 1996, 11 (01) : 283 - 291
  • [33] Influence on Formation of Methanol and Ethanol in Oil-Filled Transformers Under Accelerated Thermal Aging
    Homeier, K.
    Imani, M.
    Muenster, T.
    Kinkeldey, T.
    Werle, P.
    Philipp, D.
    PROCEEDINGS OF THE 21ST INTERNATIONAL SYMPOSIUM ON HIGH VOLTAGE ENGINEERING, VOL 1, 2020, 598 : 958 - 968
  • [34] Corrosive Sulfur Induced Failures in Oil-Filled Electrical Power Transformers and Shunt Reactors
    Scatiggio, F.
    Tumiatti, V.
    Maina, R.
    Tumiatti, M.
    Pompili, M.
    Bartnikas, R.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2009, 24 (03) : 1240 - 1248
  • [35] DESIGN FEATURES AND DISCHARGE CAPACITY OF OUTDOOR, OIL-FILLED TRANSFORMERS FOR 52 TO 750 KV
    MUSY, C
    MICHELAKAKIS, P
    BROWN BOVERI REVIEW, 1969, 56 (11-1): : 609 - +
  • [36] Hydrodynamics and heat transfer in cooling channels of oil-filled power transformers with multicoil windings
    Yatsevsky, Vitaly A.
    APPLIED THERMAL ENGINEERING, 2014, 63 (01) : 347 - 353
  • [37] A Relevant Condition Monitoring of Corrosive Sulphur Deposition on the Windings of Oil-Filled Electrical Transformers
    Jadim, R.
    Kans, M.
    Rehman, S.
    Alhems, L. M.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2020, 27 (05) : 1736 - 1742
  • [38] Development of a fibre-optic sensor for partial discharges in oil-filled power transformers
    MacAlpine, M
    Zhao, ZQ
    Demokan, MS
    ELECTRIC POWER SYSTEMS RESEARCH, 2002, 63 (01) : 27 - 36
  • [39] Raman Spectroscopy Characterization of Mineral Oil and Palm Oil with Added Multi-Walled Carbon Nanotube for Application in Oil-Filled Transformers
    Suhaimi, Nur Sabrina
    Ishak, Mohd Taufiq
    Din, Muhamad Faiz Md
    Hashim, Fakhroul Ridzuan
    Rahman, Abdul Rashid Abdul
    ENERGIES, 2022, 15 (04)
  • [40] Analysis of Damages to Oil-Filled Condenser Isolated Current Transformers of the Donbass Power System
    Shinkarenko G.V.
    Power Technology and Engineering, 2021, 54 (05) : 748 - 752