Reducing defocus aberration of a compound and human hybrid eye using liquid lens

被引:11
|
作者
Cheng, Yang [1 ]
Cao, Jie [1 ,2 ]
Meng, Lingtong [1 ]
Wang, Zihan [1 ]
Zhang, Kaiyu [1 ]
Ning, Yan [1 ]
Hao, Qun [1 ]
机构
[1] Beijing Inst Technol, Minist Educ, Key Lab Biomimet Robots & Syst, Beijing 100081, Peoples R China
[2] NUS Suzhou Res Inst NUSRI, Ind Pk, Suzhou 215123, Peoples R China
基金
中国国家自然科学基金;
关键词
ARRAYS; SIMULATIONS; FABRICATION; SYSTEM; SENSOR;
D O I
10.1364/AO.57.001679
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We propose a self-adaption focal length adjustment method of a compound and human hybrid eye with a non-uniform microlens array model (NUMLA) to reduce defocus aberration by using the liquid lens. The models are deduced and verified through simulations. The method can self-adaptively adjust the focal length according to object distance and image distance. The results show that (1) the RMS spot radii of the traditional uniform microlens array at different rings are 21 mu m, 187 mu m, 304 mu m, 526 mu m, and 803 mu m. However, those of the NUMLA are 21 mu m, 47 mu m, 98 mu m, 178 mu m, and 287 mu m, which indicates that the NUMLA can reduce the defocus aberration. (2) When the object distance and the image distance vary, the defocus aberration can be significantly reduced through the adjustment of the focal length, which validates the effectiveness of the proposed method. (3) The volumes of the liquid lens in the cavity at the peripheral rings are larger than that at the central rings. The results are beneficial for providing a simple solution to reduce the defocus aberration of the compound and human hybrid eye. (C) 2018 Optical Society of America
引用
收藏
页码:1679 / 1688
页数:10
相关论文
共 50 条
  • [31] Improvement of Filed Curvature Aberration in a Projector Lens by Using Hybrid Genetic Algorithm With Damped Least Square Optimization
    Tsai, Cheng-Mu
    Fang, Yi-Chin
    JOURNAL OF DISPLAY TECHNOLOGY, 2015, 11 (12): : 1023 - 1030
  • [32] One-lens camera using a biologically based artificial compound eye with multiple focal lengths
    Liang, Wei-Lun
    Pan, Jun-Gu
    Su, Guo-Dung J.
    OPTICA, 2019, 6 (03): : 326 - 334
  • [33] Ultrasound liquid-gel hybrid lens using acoustic radiation forces
    Miki, Haruto
    Nakamura, Kosuke
    Harada, Yuki
    Matsukawa, Mami
    Koyama, Daisuke
    APPLIED OPTICS, 2025, 64 (04) : 821 - 827
  • [34] Insect-Human Hybrid Eye (IHHE): an adaptive optofluidic lens combining the structural characteristics of insect and human eyes
    Wei, Kang
    Zeng, Hansong
    Zhao, Yi
    LAB ON A CHIP, 2014, 14 (18) : 3594 - 3602
  • [36] Chromatic aberration compensation using thin, transparent, large aperture, wide focal range, adaptive liquid crystal lens
    Pereiro-Garcia, J.
    Cano-Garcia, M.
    Blanco-Fernandez, O.
    Ramos-Una, R.
    Quintana, X.
    Geday, M. A.
    OPTICS AND LASER TECHNOLOGY, 2025, 180
  • [37] ARTIFICIAL DROSOPHILA COMPOUND EYE COMPOSED OF CURVED MICRO-LENS ARRAY USING DIRECT LASER WRITING
    Wei, Shuai
    Zhou, Zhitao
    Tao, Tiger H.
    2021 34TH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS 2021), 2021, : 915 - 918
  • [38] Combining compound eyes and human eye: a hybrid bionic imaging method for FOV extension and foveated vision
    Wang, Zihan
    Cao, Jie
    Hao, Qun
    Zhang, Fanghua
    TENTH INTERNATIONAL SYMPOSIUM ON PRECISION ENGINEERING MEASUREMENTS AND INSTRUMENTATION, 2019, 11053
  • [39] Exact determination of year-of-birth in unidentified corpses using the human eye lens
    Lynnerup, N.
    Kjeldsen, H.
    Heegaard, S.
    Jacobsen, C.
    Heinemeier, J.
    AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 2009, : 179 - 179
  • [40] Prediction of human crystalline lens power and spherical aberration using an anatomically-based discrete shell model
    Manns, Fabrice
    Ho, Arthur
    Parel, Jean-Marie
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)