Reducing defocus aberration of a compound and human hybrid eye using liquid lens

被引:11
|
作者
Cheng, Yang [1 ]
Cao, Jie [1 ,2 ]
Meng, Lingtong [1 ]
Wang, Zihan [1 ]
Zhang, Kaiyu [1 ]
Ning, Yan [1 ]
Hao, Qun [1 ]
机构
[1] Beijing Inst Technol, Minist Educ, Key Lab Biomimet Robots & Syst, Beijing 100081, Peoples R China
[2] NUS Suzhou Res Inst NUSRI, Ind Pk, Suzhou 215123, Peoples R China
基金
中国国家自然科学基金;
关键词
ARRAYS; SIMULATIONS; FABRICATION; SYSTEM; SENSOR;
D O I
10.1364/AO.57.001679
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We propose a self-adaption focal length adjustment method of a compound and human hybrid eye with a non-uniform microlens array model (NUMLA) to reduce defocus aberration by using the liquid lens. The models are deduced and verified through simulations. The method can self-adaptively adjust the focal length according to object distance and image distance. The results show that (1) the RMS spot radii of the traditional uniform microlens array at different rings are 21 mu m, 187 mu m, 304 mu m, 526 mu m, and 803 mu m. However, those of the NUMLA are 21 mu m, 47 mu m, 98 mu m, 178 mu m, and 287 mu m, which indicates that the NUMLA can reduce the defocus aberration. (2) When the object distance and the image distance vary, the defocus aberration can be significantly reduced through the adjustment of the focal length, which validates the effectiveness of the proposed method. (3) The volumes of the liquid lens in the cavity at the peripheral rings are larger than that at the central rings. The results are beneficial for providing a simple solution to reduce the defocus aberration of the compound and human hybrid eye. (C) 2018 Optical Society of America
引用
收藏
页码:1679 / 1688
页数:10
相关论文
共 50 条
  • [21] Performance of a MVE algorithm for compound eye image reconstruction using lens diversity
    Wood, SL
    Smithson, BJ
    Rajan, D
    Christensen, MP
    2005 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, VOLS 1-5: SPEECH PROCESSING, 2005, : 593 - 596
  • [22] RECONSTRUCTION OF THREE-DIMENSIONAL IMAGE FROM COMPOUND-EYE IMAGING WITH DEFOCUS USING RAY TRACING
    Miyazaki, Daisuke
    Ito, Katsuaki
    Nakao, Yoshizumi
    Toyoda, Takashi
    Masaki, Yasuo
    INTERNATIONAL JOURNAL OF INNOVATIVE COMPUTING INFORMATION AND CONTROL, 2009, 5 (11B): : 4225 - 4235
  • [23] Optical Model of a Human Eye's Crystalline Lens Based on a Three-layer Liquid Lens
    Kong, Meimei
    Chen, Xin
    Yuan, Yang
    Zhao, Rui
    Chen, Tao
    Liang, Zhongcheng
    CURRENT OPTICS AND PHOTONICS, 2019, 3 (02) : 177 - 180
  • [24] Relationship between the subjectively and objectively determined depth of focus of the human eye using defocus curves
    Leube, Alexander
    Ohlendorf, Arne
    Tabernero, Juan
    Wahl, Siegfried
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [25] Compact and fast depth sensor based on a liquid lens using chromatic aberration to improve accuracy
    Jung, Gyu Suk
    Won, Yong Hyub
    OPTICS EXPRESS, 2021, 29 (10) : 15786 - 15801
  • [26] High NA objective lens wavefront aberration measurement using a cat-eye retroreflector and Zernike polynomial
    Li, Peng
    Tang, Feng
    Wang, Xiangzhao
    Li, Jie
    OPTICS EXPRESS, 2021, 29 (20) : 31812 - 31835
  • [27] Measurement of wavefront aberration of human eye using Talbot image of two-dimensional grating
    Sekine, Ryotaro
    Shibuya, Takashi
    Ukai, Kazuhiko
    Komatsu, Shinichi
    Hattori, Masayuki
    Mihashi, Toshifumi
    Nakazawa, Naoki
    Hirohara, Yoko
    OPTICAL REVIEW, 2006, 13 (04) : 207 - 211
  • [28] Method of Human Eye Aberration Measurement Using Plenoptic Camera Over Large Field of View
    Lv, Yang
    Wang, Ruixing
    Ma, Haotong
    Zhang, Xuanzhe
    Ning, Yu
    Xu, Xiaojun
    MEDICAL PHYSICS, 2016, 43 (06) : 3679 - 3679
  • [29] Measurement of Wavefront Aberration of Human Eye Using Talbot Image of Two-Dimensional Grating
    Ryotaro Sekine
    Takashi Shibuya
    Kazuhiko Ukai
    Shinichi Komatsu
    Masayuki Hattori
    Toshifumi Mihashi
    Naoki Nakazawa
    Yoko Hirohara
    Optical Review, 2006, 13 : 207 - 211
  • [30] Reducing driving voltages for liquid crystal lens using weakly conductive thin film
    Ye, Mao
    Wang, Bin
    Yamaguch, Maki
    Sato, Susumu
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2008, 47 (06) : 4597 - 4599