Cardiac output monitoring devices: an analytic review

被引:12
|
作者
Porhomayon, Jahan [1 ]
El-Solh, Ali [2 ]
Papadakos, Peter [3 ]
Nader, Nader Djalal [1 ]
机构
[1] SUNY Buffalo, Sch Med & Biomed Sci, Dept Anesthesiol, VA Western New York Healthcare Syst, Buffalo, NY 14215 USA
[2] SUNY Buffalo, Sch Med & Biomed Sci, Div Pulm, Dept Med Crit Care & Sleep Med,VA Western New Yor, Buffalo, NY 14215 USA
[3] Univ Rochester, Crit Care Med & Trauma Intens Care Unit, Div Anesthesiol Crit Care Med, Strong Mem Hosp, Rochester, NY USA
关键词
Cardiac output; FloTrac; LiDCO; Esophageal Doppler; Echocardiography; ECOM; PiCCO; Pulmonary artery catheter; PULMONARY-ARTERY CATHETER; WAVE-FORM ANALYSIS; EXTRAVASCULAR LUNG WATER; PULSE-CONTOUR ANALYSIS; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; THERMODILUTION; SYSTEM; VOLUME; MANAGEMENT; VALIDITY;
D O I
10.1007/s11739-011-0738-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To evaluate cardiac output (CO), both invasive and semi-invasive monitors are used in critical care medicine. The pulmonary artery catheter is an invasive tool to assess CO with the major criticism that the level of its invasiveness is not supported by an improvement in patients' outcomes. The interest in a lesser invasive techniques is high. Therefore, alternative techniques have been developed recently, and are used frequently in critical care medicine. Cardiac output can be monitored continuously by different devices that analyze the stroke volume and CO. The purpose of this review is to understand these new technologies and their applications and limitations.
引用
收藏
页码:163 / 171
页数:9
相关论文
共 50 条
  • [21] Cardiac output monitoring in newborns
    de Boode, Willem-Pieter
    EARLY HUMAN DEVELOPMENT, 2010, 86 (03) : 143 - 148
  • [22] Accuracy and precision of non-invasive cardiac output monitoring devices in perioperative medicine: a systematic review and meta-analysis
    Joosten, A.
    Desebbe, O.
    Suehiro, K.
    Murphy, L. S. -L.
    Essiet, M.
    Alexander, B.
    Fischer, M. -O.
    Barvais, L.
    Van Obbergh, L.
    Maucort-Boulch, D.
    Cannesson, M.
    BRITISH JOURNAL OF ANAESTHESIA, 2017, 118 (03) : 298 - 310
  • [23] Haemodynamic monitoring or output cardiac monitoring? Reply
    Brissaud, O.
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2011, 30 (01): : 87 - 87
  • [24] Monitoring: from cardiac output monitoring to echocardiography
    Jozwiak, Mathieu
    Monnet, Xavier
    Teboul, Jean-Louis
    CURRENT OPINION IN CRITICAL CARE, 2015, 21 (05) : 395 - 401
  • [25] A systematic review of cerebral oxygenation-monitoring devices in cardiac surgery
    Douds, M. T.
    Straub, E. J.
    Kent, A. C.
    Bistrick, C. H.
    Sistino, J. J.
    PERFUSION-UK, 2014, 29 (06): : 545 - 552
  • [26] A prospective study of the accuracy and precision of continuous cardiac output monitoring devices as compared to intermittent thermodilution
    Cecconi, M.
    Dawson, D.
    Casaretti, R.
    Grounds, R. M.
    Rhodes, A.
    MINERVA ANESTESIOLOGICA, 2010, 76 (12) : 1010 - 1017
  • [27] Feasibility of cardiac output estimation by ultrasonic cardiac output monitoring in the prehospital setting
    Duchateau, Francois-Xavier
    Gauss, Tobias
    Burnod, Alexis
    Ricard-Hibon, Agnes
    Juvin, Philippe
    Mantz, Jean
    EUROPEAN JOURNAL OF EMERGENCY MEDICINE, 2011, 18 (06) : 357 - 359
  • [28] Minimally invasive cardiac output monitoring
    Morgan, Patrick
    Al-Subaie, Nawaf
    Rhodes, Andrew
    CURRENT OPINION IN CRITICAL CARE, 2008, 14 (03) : 322 - 326
  • [29] Cardiac Output Monitoring and Fluid Responsiveness
    Lazaridis, Christos
    NEUROCRITICAL CARE, 2012, 16 (03) : 486 - 487
  • [30] Cardiac Output Monitoring and Fluid Responsiveness
    Christos Lazaridis